Accuracy of Pedicle Screw Placement and Clinical Outcomes of Robot-assisted Technique Versus Conventional Freehand Technique in Spine Surgery From Nine Randomized Controlled Trials: A Meta-analysis
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Study Design.: A meta-analysis. Objective.: To investigate whether robot-assisted techniques are superior to conventional techniques in terms of the accuracy of pedicle screw placement and clinical indexes. Summary of Background Data.: Robot-assisted techniques are increasingly applied to spine surgery to reduce the rate of screw misplacement. However, controversy about the superiority of robot-assisted techniques over conventional freehand techniques remains. Methods.: We conducted a comprehensive search of PubMed, EMBASE, and Cochrane Library for potentially eligible articles. The outcomes were evaluated in terms of risk ratio (RR) or standardized mean difference and the associated 95% confidence intervals (CIs). Meta-analysis was performed using the RevMan 5.3 software and subgroup analyses were performed based on the robot type for the accuracy of pedicle screw placement. Results.: Nine randomized controlled trials with 696 patients were included in this meta-analysis. The results demonstrated that the robot-assisted technique was more accurate in pedicle screw placement than the freehand technique. Subgroup analyses showed that the TINAVI robot-assisted technique was more accurate in screw positions Grade A (RR, 1.10; 95% CI, 1.06–1.14), Grade B (RR, 0.46; 95% CI, 0.28–0.75), and Grades C + D + E (RR, 0.21; 95% CI, 0.09–0.45) than the freehand technique, whereas the Renaissance robot-assisted technique showed the same accuracy as the freehand technique in screw positions Grade A, Grade B, and Grades C + D + E. Furthermore, the robot-assisted techniques showed equivalent postoperative stay, visual analogue scale scores, and Oswestry disability index scores to those of the freehand technique and shorter intraoperative radiation exposure time, fewer radiation dose and proximal facet violations but longer surgical time than the freehand technique. Conclusion.: The robot-assisted technique is more accurate in pedicle screw placement than the freehand technique. And TINAVI robot-assisted pedicle screw placement is a more accurate alternative to conventional techniques and the Renaissance robot-assisted procedure. Level of Evidence: 1
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00136 · Cited by 10,349 · cited 1×
“This meta-analysis was performed according to Cochrane Handbook for Systematic Reviews of Interventions(16) and presented based on the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines.(17)”
MethodAccuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Esses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
Thoracic Human Vertebrae Quantitative Three-Dimensional Anatomy
PANJABI, M. M., TAKATA, K., GOEL, V., FEDERICO, D., OXLAND, T., DURANCEAU, J., & KRAG, M. (1991) · SPINE · doi:10.1097/00007632-199108000-00006 · Cited by 396
Mason, A., Paulsen, R., Babuska, J. M., Rajpal, S., Burneikiene, S., Nelson, E. L., & Villavicencio, A. T. (2014) · Journal of Neurosurgery: Spine · doi:10.3171/2013.11.spine13413 · Cited by 384 · cited 1×
“Other researchers found that the conventional techniques used in pedicle screw placement cause screw misplacement, with rates ranging from 3% to 55%.(3) Clearly, precision in pedicle screw placement is of utmost importance, and robotic assistance techniques are being applied increasingly in spine surgery to increase t…”
BackgroundAccuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws
Ringel, F. A., Stüer, C., Reinke, A. N., Preuß, A., Behr, M., Auer, F., Stoffel, M. H., & Meyer, B. (2012) · Spine · doi:10.1097/brs.0b013e31824b7767 · Cited by 347 · cited 2×
“However, the reported accuracy of screw placement via the SpineAssist/Renaissance robot varies widely, and according to a prospective randomized comparison to conventional freehand screw implantation, the accuracy assessment of screw placement by Gertzbin–Robbins classification(18) indicates that the conventional free…”
MethodResultHyun, S.-J., Kim, K.-J., Jahng, T.-A., & Kim, H.-J. (2017) · Spine · doi:10.1097/brs.0000000000001778 · Cited by 305
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Kim, H., Jung, W., Chang, B., Lee, C., Kang, K., & Yeom, J. S. (2017) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1779 · Cited by 240 · cited 2×
“However, 2 prospective, randomized, controlled trials demonstrated that robot-assisted pedicle fixation has the same pedicle screw placement accuracy as and even less than that of the freehand conventional technique.(11,12) Furthermore, some researchers revealed through a meta-analysis that the robot-assisted pedicle…”
ResultMethods to determine pedicle screw placement accuracy in spine surgery: a systematic review
Aoude, A. A., Fortin, M., Figueiredo, R., Jarzem, P., Ouellet, J., & Weber, M. H. (2015) · European Spine Journal · doi:10.1007/s00586-015-3853-x · Cited by 223 · cited 1×
“C damage, dural tearing, or visceral involvement, and such complications are potential threats to life and limb.(8)”
BackgroundSchatlo, B., Molliqaj, G., Cuvinciuc, V., Kotowski, M., Schaller, K., & Tessitore, E. (2014) · Journal of Neurosurgery: Spine · doi:10.3171/2014.3.spine13714 · Cited by 220
Gao, S., Lv, Z., & Fang, H. (2017) · European Spine Journal · doi:10.1007/s00586-017-5333-y · Cited by 165
Yu, L., Chen, X., Margalit, A., Peng, H., Qiu, G., & Qian, W. (2018) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1892 · Cited by 104
Park, S., Kim, H., Lee, S. Y., Chang, B., Lee, C., & Yeom, J. S. (2018) · Yonsei Medical Journal · doi:10.3349/ymj.2018.59.3.438 · Cited by 58
Kim, H., Kang, K., Chun, H., Hwang, J. S., Chang, B., Lee, C., & Yeom, J. S. (2018) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1917 · Cited by 40
Alaid, A. O., von Eckardstein, K., Smoll, N. R., Solomiichuk, V., Rohde, V., Martínez, R., & Schatlo, B. (2017) · Neurosurgical Review · doi:10.1007/s10143-017-0877-1 · Cited by 34 · cited 1×
“The advantage of the robot-assisted technique in reducing radiation dose and intraoperative radiation exposure time was also reported in some studies.(38,39) This may be explained by the fact that robot-assisted techniques are based on preoperative or intraoperative computed tomography data for image registration, tra…”
BackgroundPediatric superior semicircular canal dehiscence: illustrative case and systematic review
Lagman, C., Ong, V., Chung, L. K., Elhajjmoussa, L., Fong, C., Wang, A., Gopen, Q. S., & Yang, I. (2017) · Journal of Neurosurgery Pediatrics · doi:10.3171/2017.3.peds1734 · Cited by 26
Cited by
Telerobotic Spinal Surgery Based on 5G Network: The First 12 Cases
Tian, W., Fan, M., Zeng, C., Liu, Y., He, D., & Zhang, Q. (2020) · Neurospine · doi:10.14245/ns.1938454.227 · Cited by 255
Metadata
- Authors
- Li, H.-M., Zhang, R.-J., & Shen, C.-L.
- Venue
- Spine
- Published
- 2020-01-15
- Volume
- 45
- Issue
- 2
- Pages
- E111-E119
- ISSN
- 0362-2436 (ISSN-L)
- 1528-1159
- OpenAlex
- W2968304512
- Cited by
- 197
- References
- 20
- FWCI
- 15.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.