CoChat

Polyethylene Glycol Hydrogel Spinal Sealant (DuraSeal Spinal Sealant) as an Adjunct to Sutured Dural Repair in the Spine: Results of a Prospective, Multicenter, Randomized Controlled Study

Kim, Kee D., Wright, Neill M. · 2011 · Spine
Cited by 117

The DOI matches its Crossref record.

Abstract

STUDY DESIGN: A prospective, multicenter, randomized, two-arm, single-blind, investigational device exemption pivotal study. OBJECTIVE: To assess the efficacy and the safety of a polyethylene glycol (PEG) hydrogel spinal sealant (DuraSeal Spinal Sealant) as an adjunct to sutured dural repair compared with standard of care methods (control) to obtain a watertight dural closure in patients undergoing an intentional durotomy during spinal surgery. SUMMARY OF BACKGROUND DATA: If a watertight dural closure is not achieved, cerebrospinal fluid leak with associated complications may occur. The PEG hydrogel spinal sealant is an Food and Drug Administration (FDA)-approved adjunct to sutured dural repair in spine surgery. This synthetic, absorbable hydrogel sealant works in the presence of fluid, conforms to irregular surfaces, and demonstrates strong adherence and compliance to tissue, without interfering with underlying tissue visibility. METHODS: A total of 158 patients were treated at 24 centers after they were randomized on the basis of an approximately 2:1 ratio (sealant:control); 102 received the PEG hydrogel spinal sealant and 56 received standard care. The primary end point was intraoperative watertight closure. Secondary end points included evaluations of postoperative cerebrospinal fluid leak, infection, and wound healing. RESULTS: Patients treated with the PEG hydrogel spinal sealant had a significantly higher rate of watertight closure than the control (100% vs. 64.3%, P < 0.001). No statistical differences were seen in postoperative cerebrospinal fluid leak, infection, and wound healing. No neurologic deficits were seen attributable to the sealant. CONCLUSION: The PEG hydrogel spinal sealant evaluated in this study is safe and effective for providing watertight closure when used as an adjunct to sutured dural repair during spinal surgery. This readily available tool is superior to other standard of care technologies commonly used to achieve intraoperative watertight dural closure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e3181fdb4db

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kim, K. D., & Wright, N. M.
Venue
Spine
Published
2011-11
Volume
36
Issue
23
Pages
1906-1912
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2012516413
Cited by
117
References
0
FWCI
5.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.