Arterial Pulse Pressure Variation with Mechanical Ventilation
The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Fluid administration leads to a significant increase in cardiac output in only half of ICU patients. This has led to the concept of assessing fluid responsiveness before infusing fluid. Pulse pressure variation (PPV), which quantifies the changes in arterial pulse pressure during mechanical ventilation, is one of the dynamic variables that can predict fluid responsiveness. The underlying hypothesis is that large respiratory changes in left ventricular stroke volume, and thus pulse pressure, occur in cases of biventricular preload responsiveness. Several studies showed that PPV accurately predicts fluid responsiveness when patients are under controlled mechanical ventilation. Nevertheless, in many conditions encountered in the ICU, the interpretation of PPV is unreliable (spontaneous breathing, cardiac arrhythmias) or doubtful (low Vt). To overcome some of these limitations, researchers have proposed using simple tests such as the Vt challenge to evaluate the dynamic response of PPV. The applicability of PPV is higher in the operating room setting, where fluid strategies made on the basis of PPV improve postoperative outcomes. In medical critically ill patients, although no randomized controlled trial has compared PPV-based fluid management with standard care, the Surviving Sepsis Campaign guidelines recommend using fluid responsiveness indices, including PPV, whenever applicable. In conclusion, PPV is useful for managing fluid therapy under specific conditions where it is reliable. The kinetics of PPV during diagnostic or therapeutic tests is also helpful for fluid management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudski, L. G., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,049
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621 · cited 13×
“individualization of hemodynamic therapy and occupies a major place in guiding resuscitation of ICU patients today (8, 9).”
BackgroundMethodInfluentialSepsis in European intensive care units: Results of the SOAP study*
Vincent, J.-L., Sakr, Y., Sprung, C. L., Ranieri, V. M., Reinhart, K., Gerlach, H., Moreno, R., Carlet, J., Le Gall, J.-R., & Payen, D. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194725.48928.3a · Cited by 2,836 · cited 1×
“Nevertheless, given that fluid overload may cause harm to ICU patients (11), particularly to fluid non-responders (12), it is important to detect fluid responsiveness before administering any fluid.”
BackgroundThe Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Relevance of Lung Ultrasound in the Diagnosis of Acute Respiratory Failure*: The BLUE Protocol
Lichtenstein, D. A., & Mezière, G. A. (2008) · Chest · doi:10.1378/chest.07-2800 · Cited by 2,068 · cited 1×
“In cases where the risks of lung edema are not negligible, additional variables, such as extravascular lung water (74) or the presence of B-lines on lung ultrasound examination (75), are useful in making the appropriate decision.”
BackgroundCecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationFan, E., Del Sorbo, L., Goligher, E. C., Hodgson, C. L., Munshi, L., Walkey, A. J., Adhikari, N. K. J., Amato, M. B. P., Branson, R., Brower, R. G., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0548st · Cited by 1,630
Elevation of Systemic Oxygen Delivery in the Treatment of Critically Ill Patients
Hayes, M. A., Timmins, A. C., Yau, E., Palazzo, M., Hinds, C. J., & Watson, D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406163302404 · Cited by 1,538 · cited 1×
“The factors that contributed to this decline are multiple, including the publication of randomized controlled trials that showed either no benefit (2) or even deleterious effects (3) of strategies aimed at maximizing oxygen delivery in the intensive care unit (ICU) patients.”
BackgroundA Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients
Gattinoni, L., Brazzi, L., Pelosi, P., Latini, R., Tognoni, G., Pesenti, A., & Fumagalli, R. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510193331601 · Cited by 1,510
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458 · cited 11×
“Accordingly, we showed that PPV was a better predictor of fluid responsiveness than SPV (24).”
BackgroundInfluentialSelf-citation
Cited by
Prediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
“This was confirmed in a meta-analysis of 11 studies (1015 patients) performed in surgical ICU patients and in which a strategy based on SVV reduced the ICU and hospital lengths of stay and tended to decrease mortality [101].”
BackgroundInfluentialSelf-citationHow can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“The essential limitation of PPV is that it cannot be used in many clinical circumstances that create false positives (spontaneous ventilation, cardiac arrhythmia, right ventricular failure) and false negatives (low tidal volume, low lung compliance, very high respiratory rate) [54].”
BackgroundSelf-citationFluid Therapy for Critically Ill Adults With Sepsis: A Review
Zampieri, F. G., Bagshaw, S. M., & Semler, M. W. (2023) · JAMA · doi:10.1001/jama.2023.7560 · Cited by 184
Metadata
- Authors
- Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-01-01
- Volume
- 199
- Issue
- 1
- Pages
- 22-31
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2888605280
- Cited by
- 200
- References
- 69
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arterial Pulse Pressure Variation with Mechanical Ventilation. https://app.cochat.ai/papers/10.1164/rccm.201801-0088ci
- The paper
- Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019). Arterial Pulse Pressure Variation with Mechanical Ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/rccm.201801-0088ci
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.