Assessment of Lung Aeration and Recruitment by CT Scan and Ultrasound in Acute Respiratory Distress Syndrome Patients*
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Objectives: Lung ultrasound is commonly used to evaluate lung morphology in patients with acute respiratory distress syndrome. Aim of this study was to determine lung ultrasound reliability in assessing lung aeration and positive end-expiratory pressure–induced recruitment compared with CT. Design: Randomized crossover study. Setting: University hospital ICU. Patients: Twenty sedated paralyzed acute respiratory distress syndrome patients: age 56 years (43–72 yr), body mass index 25 kg/m 2 (22–27 kg/m 2), and Pa o 2/F io 2 160 (113–218). Interventions: Lung CT and lung ultrasound examination were performed at positive end-expiratory pressure 5 and 15 cm H 2 O. Measurements and Main Results: Global and regional Lung Ultrasound scores were compared with CT quantitative analysis. Lung recruitment (i.e., decrease in not aerated tissue as assessed with CT) was compared with global Lung Ultrasound score variations. Global Lung Ultrasound score was strongly associated with average lung tissue density at positive end-expiratory pressure 5 (R 2 = 0.78; p < 0.0001) and positive end-expiratory pressure 15 (R 2 = 0.62; p < 0.0001). Regional Lung Ultrasound score strongly correlated with tissue density at positive end-expiratory pressure 5 (r s = 0.79; p < 0.0001) and positive end-expiratory pressure 15 (r s = 0.79; p < 0.0001). Each step increase of regional Lung Ultrasound score was associated with significant increase of tissue density (p < 0.005). A substantial agreement was found between regional Lung Ultrasound score and CT classification at positive end-expiratory pressure 5 (k = 0.69 [0.63–0.75]) and at positive end-expiratory pressure 15 (k = 0.70 [0.64–0.75]). At positive end-expiratory pressure 15, both global Lung Ultrasound score (22 [16–27] vs 26 [21–29]; p < 0.0001) and not aerated tissue (42% [25–57%] vs 52% [39–67%]; p < 0.0001) decreased. However, Lung Ultrasound score variations were not associated with lung recruitment (R 2 = 0.01; p = 0.67). Conclusions: Lung Ultrasound score is a valid tool to assess regional and global lung aeration. Global Lung Ultrasound score variations should not be used for bedside assessment of positive end-expiratory pressure–induced recruitment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Acute Respiratory Distress Syndrome: The Berlin Definition
(2012) · JAMA · doi:10.1001/jama.2012.5669 · Cited by 8,731
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093
International evidence-based recommendations for point-of-care lung ultrasound
International Liaison Committee on Lung Ultrasound (ILC-LUS) for the International Consensus Conference on Lung Ultrasound (ICC-LUS), Volpicelli, G., Elbarbary, M., Blaivas, M., Lichtenstein, D. A., Mathis, G., Kirkpatrick, A. W., Melniker, L., Gargani, L., Noble, V. E., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2513-4 · Cited by 2,874
Self-citationLung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548
Self-citationBriel, M., Meade, M., Mercat, A., Brower, R. G., Talmor, D., Walter, S. D., Slutsky, A. S., Pullenayegum, E., Zhou, Q., Cook, D., et al. (2010) · JAMA · doi:10.1001/jama.2010.218 · Cited by 1,467
Clinical Trial Registration: A Statement from the International Committee of Medical Journal Editors
De Angelis, C., Drazen, J. M., Frizelle, F. A., Haug, C., Hoey, J., Horton, R., Kotzin, S., Laine, C., Marusic, A., Overbeke, A. J. P. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejme048225 · Cited by 1,241
Gattinoni, L., Pesenti, A., Avalli, L., Rossi, F., & Bombino, M. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.3.730 · Cited by 900
What Has Computed Tomography Taught Us about the Acute Respiratory Distress Syndrome?
GATTINONI, L., CAIRONI, P., PELOSI, P., & GOODMAN, L. R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.9.2103121 · Cited by 753
Bedside Ultrasound Assessment of Positive End-Expiratory Pressure–induced Lung Recruitment
Bouhemad, B., Brisson, H., Le-Guen, M., Arbelot, C., Lu, Q., & Rouby, J.-J. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201003-0369oc · Cited by 735
“Ultrasound Comet-Tail Images”: A Marker Of Pulmonary Edema
Agricola, E., Bove, T., Oppizzi, M., Marino, G., Zangrillo, A., Margonato, A., & Picano, E. (2005) · Chest · doi:10.1378/chest.127.5.1690 · Cited by 597
Copetti, R., Soldati, G., & Copetti, P. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-16 · Cited by 555
Soummer, A., Perbet, S., Brisson, H., Arbelot, C., Constantin, J.-M., Lu, Q., & Rouby, J.-J. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31824e68ae · Cited by 519
Recruitment Maneuvers for Acute Lung Injury
Fan, E., Wilcox, M. E., Brower, R. G., Stewart, T. E., Mehta, S., Lapinsky, S. E., Meade, M. O., & Ferguson, N. D. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200802-335oc · Cited by 328
Ultrasound for “Lung Monitoring” of Ventilated Patients
Bouhemad, B., Mongodi, S., Via, G., & Rouquette, I. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000558 · Cited by 317
Self-citationon behalf of the investigators of the Acurasys and Proseva trials, Guérin, C., Papazian, L., Reignier, J., Ayzac, L., Loundou, A., & Forel, J.-M. (2016) · Critical Care · doi:10.1186/s13054-016-1556-2 · Cited by 266
Zhao, Z., Jiang, L., Xi, X., Jiang, Q., Zhu, B., Wang, M., Xing, J., & Zhang, D. (2015) · BMC Pulmonary Medicine · doi:10.1186/s12890-015-0091-2 · Cited by 178
Modified Lung Ultrasound Score for Assessing and Monitoring Pulmonary Aeration
Mongodi, S., Bouhemad, B., Orlando, A., Stella, A., Tavazzi, G., Via, G., Iotti, G., Braschi, A., & Mojoli, F. (2017) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0042-120260 · Cited by 178
Self-citationImaging in acute respiratory distress syndrome
Pesenti, A. M., Musch, G., Lichtenstein, D. A., Mojoli, F., Amato, M. B. P., Cinnella, G., Gattinoni, L., & Quintel, M. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4328-1 · Cited by 162
Self-citationChiumello, D., Marino, A., Brioni, M., Cigada, I., Menga, F., Colombo, A., Crimella, F., Algieri, I., Cressoni, M., Carlesso, E., et al. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201507-1413oc · Cited by 161
Self-citationMongodi, S., Pozzi, M., Orlando, A., Bouhemad, B., Stella, A., Tavazzi, G., Via, G., Iotti, G. A., & Mojoli, F. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4941-7 · Cited by 87
Self-citationCressoni, M., Chiumello, D., Carlesso, E., Chiurazzi, C., Amini, M., Brioni, M., Cadringher, P., Quintel, M., & Gattinoni, L. (2014) · Anesthesiology · doi:10.1097/aln.0000000000000373 · Cited by 82
Self-citation
Cited by
Lung Ultrasound for Critically Ill Patients
Mojoli, F., Bouhemad, B., Mongodi, S., & Lichtenstein, D. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0236ci · Cited by 513
Self-citationThoracic ultrasonography: a narrative review
Mayo, P. H., Copetti, R., Feller-Kopman, D., Mathis, G., Maury, E., Mongodi, S., Mojoli, F., Volpicelli, G., & Zanobetti, M. (2019) · Intensive Care Medicine · doi:10.1007/s00134-019-05725-8 · Cited by 266
Self-citationQuantitative Lung Ultrasound: Technical Aspects and Clinical Applications
Mongodi, S., De Luca, D., Colombo, A., Stella, A., Santangelo, E., Corradi, F., Gargani, L., Rovida, S., Volpicelli, G., Bouhemad, B., et al. (2021) · Anesthesiology · doi:10.1097/aln.0000000000003757 · Cited by 242
“Regional scores showed strong correlations with lung density measured by quantitative computed tomography.(22) The global lung ultrasound score is computed as the sum of regional scores; therefore, the total score ranges from 0 to 36.”
BackgroundMethodSelf-citationPersonalized mechanical ventilation in acute respiratory distress syndrome
Pelosi, P., Ball, L., Barbas, C. S. V., Bellomo, R., Burns, K. E. A., Einav, S., Gattinoni, L., Laffey, J. G., Marini, J. J., Myatra, S. N., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03686-3 · Cited by 217
“Notwithstanding, sensitivity of LUS to detect alveolar recruitment is variable across studies [68].”
BackgroundMethodEffect of mechanical power on intensive care mortality in ARDS patients
Coppola, S., Caccioppola, A., Froio, S., Formenti, P., De Giorgis, V., Galanti, V., Consonni, D., & Chiumello, D. (2020) · Critical Care · doi:10.1186/s13054-020-02963-x · Cited by 181
Self-citation
Metadata
- Authors
- Chiumello, D., Mongodi, S., Algieri, I., Vergani, G. L., Orlando, A., Via, G., Crimella, F., Cressoni, M., & Mojoli, F.
- Venue
- Critical Care Medicine
- Published
- 2018-11
- Volume
- 46
- Issue
- 11
- Pages
- 1761-1768
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2883473174
- Cited by
- 308
- References
- 22
- FWCI
- 22.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.