Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Comparison of delirium assessment tools in a mixed intensive care unit*

van Eijk, Maarten M. J., van Marum, Rob J., Klijn, Ine A. M., de Wit, Nelleke, Kesecioglu, Jozef, Slooter, Arjen J. C. · 2009 · Critical Care Medicine

Abstract

OBJECTIVE: Delirium is a frequent problem in the intensive care unit (ICU) associated with poor prognosis. Delirium in the ICU is underdiagnosed by nursing and medical staff. Several detection methods have been developed for use in ICU patients. The aim of this study was to compare the value of three detection methods (the Confusion Assessment Method for the ICU [CAM-ICU], the Intensive Care Delirium Screening Checklist [ICDSC] and the impression of the ICU physician with the diagnosis of a psychiatrist, neurologist, or geriatrician). DESIGN: Prospective study. SETTING AND PATIENTS: During an 8-month period, 126 patients (mean age 62.4 years, sd 15.0; mean Acute Physiology and Chronic Health Evaluation II score 20.9, sd 7.5) admitted to a 32-bed mixed medical and surgical ICU were studied. MEASUREMENTS: The included patients were assessed independently by trained ICU nurses using either the CAM-ICU or the ICDSC. Furthermore, the ICU physician was asked whether a patient was delirious or not. A psychiatrist, geriatrician, or neurologist serving as reference rater diagnosed delirium using established criteria. MAIN RESULTS: The CAM-ICU showed superior sensitivity and negative predictive value (64% and 83%) compared with the ICDSC (43% and 75%). The ICDSC showed higher specificity and positive predictive value (95% and 82% vs. 88% and 72%). The sensitivity of the physicians view was only 29%. CONCLUSIONS: ICU physicians underdiagnose delirium in the ICU, which underlines the necessity of standard evaluation in all critically ill patients. In our mixed ICU population, the CAM-ICU had a higher sensitivity than the ICDSC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181a00118

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 333

Metadata

Authors
van Eijk, M. M. J., van Marum, R. J., Klijn, I. A. M., de Wit, N., Kesecioglu, J., & Slooter, A. J. C.
Venue
Critical Care Medicine
Published
2009-06
Volume
37
Issue
6
Pages
1881-1885
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2047716792
Cited by
333
References
24
FWCI
15.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of delirium assessment tools in a mixed intensive care unit*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181a00118
The paper
van Eijk, M. M. J., van Marum, R. J., Klijn, I. A. M., de Wit, N., Kesecioglu, J., & Slooter, A. J. C. (2009). Comparison of delirium assessment tools in a mixed intensive care unit*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181a00118

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.