Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record.

The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension*

Mahjoub, Yazine, Touzeau, Jérémie, Airapetian, Norair, Lorne, Emmanuel, Hijazi, Mustapha, Zogheib, Elie, Tinturier, François, Slama, Michel, Dupont, Hervé · 2010 · Critical Care Medicine

Abstract

OBJECTIVES: The passive leg-raising maneuver is a reversible fluid-loading procedure used to predict fluid responsiveness in mechanically ventilated patients. The aim of the present study was to determine whether intra-abdominal hypertension (which impairs venous return) reduces the ability of passive leg raising to detect fluid responsiveness in critically ill ventilated patients. DESIGN: A prospective study. SETTING: The medical and surgical intensive care unit of a university medical center. PATIENTS: Forty-one mechanically ventilated patients with a pulse pressure variation of >12%. INTERVENTIONS: Stroke volume was continuously monitored by esophageal Doppler. Intra-abdominal pressure was measured via bladder pressure. After a passive leg-raising maneuver and a return to baseline, fluid loading with 500 mL of saline was performed. Hemodynamic parameters were recorded at each step. Nonresponders to volume loading were not analyzed (10 patients). Thirty-one patients were classified into two groups according to their response to passive leg raising: responders to passive leg raising (at least a 12% increase in stroke volume) and nonresponders to passive leg raising. MEASUREMENTS AND MAIN RESULTS: Sixteen patients (52%) were responders to passive leg raising, and 15 (48%) were nonresponders to passive leg raising (i.e., false negatives). At baseline, the median intra-abdominal pressure was significantly higher in the nonresponders to passive leg raising than in the responders to passive leg raising (20 [6.5] vs. 11.5 [5.5], respectively; p < .0001). The area under the receiver-operating characteristic curve was 0.969 +/- 0.033. An intra-abdominal pressure cutoff value of 16 mm Hg discriminated between responders to passive leg raising and nonresponders to passive leg raising with a sensitivity of 100% (confidence interval, 78-100) and a specificity of 87.5% (confidence interval, 61.6-98.1). An intra-abdominal pressure of > or =16 mm Hg was the only independent predictor of nonresponse to passive leg raising in a multivariate analysis (odds ratio, 2.6 [confidence interval, 1.1-6.6]; p = .04). CONCLUSIONS: An intra-abdominal pressure of > or =16 mm Hg seems to be responsible for false negatives to passive leg raising. Hence, the intra-abdominal pressure should be measured in critically ill ventilated patients, especially before performing passive leg raising.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181eb3c21

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Mahjoub, Y., Touzeau, J., Airapetian, N., Lorne, E., Hijazi, M., Zogheib, E., Tinturier, F., Slama, M., & Dupont, H.
Venue
Critical Care Medicine
Published
2010-09
Volume
38
Issue
9
Pages
1824-1829
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1988786183
Cited by
184
References
0
FWCI
13.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.