Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Automated drug dispensing system reduces medication errors in an intensive care setting

Open access
Chapuis, Claire, Roustit, Matthieu, Bal, Gaëlle, Schwebel, Carole, Pansu, Pascal, David-Tchouda, Sandra, Foroni, Luc, Calop, Jean, Timsit, Jean-François, Allenet, Benoît, Bosson, Jean-Luc, Bedouch, Pierrick·2010·Critical Care Medicine

Abstract

OBJECTIVES: We aimed to assess the impact of an automated dispensing system on the incidence of medication errors related to picking, preparation, and administration of drugs in a medical intensive care unit. We also evaluated the clinical significance of such errors and user satisfaction. DESIGN: Preintervention and postintervention study involving a control and an intervention medical intensive care unit. SETTING: Two medical intensive care units in the same department of a 2,000-bed university hospital. PATIENTS: Adult medical intensive care patients. INTERVENTIONS: After a 2-month observation period, we implemented an automated dispensing system in one of the units (study unit) chosen randomly, with the other unit being the control. MEASUREMENTS AND MAIN RESULTS: The overall error rate was expressed as a percentage of total opportunities for error. The severity of errors was classified according to National Coordinating Council for Medication Error Reporting and Prevention categories by an expert committee. User satisfaction was assessed through self-administered questionnaires completed by nurses. A total of 1,476 medications for 115 patients were observed. After automated dispensing system implementation, we observed a reduced percentage of total opportunities for error in the study compared to the control unit (13.5% and 18.6%, respectively; p<.05); however, no significant difference was observed before automated dispensing system implementation (20.4% and 19.3%, respectively; not significant). Before-and-after comparisons in the study unit also showed a significantly reduced percentage of total opportunities for error (20.4% and 13.5%; p<.01). An analysis of detailed opportunities for error showed a significant impact of the automated dispensing system in reducing preparation errors (p<.05). Most errors caused no harm (National Coordinating Council for Medication Error Reporting and Prevention category C). The automated dispensing system did not reduce errors causing harm. Finally, the mean for working conditions improved from 1.0±0.8 to 2.5±0.8 on the four-point Likert scale. CONCLUSIONS: The implementation of an automated dispensing system reduced overall medication errors related to picking, preparation, and administration of drugs in the intensive care unit. Furthermore, most nurses favored the new drug dispensation organization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181f8569b

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 159

Metadata

Authors
Chapuis, C., Roustit, M., Bal, G., Schwebel, C., Pansu, P., David-Tchouda, S., Foroni, L., Calop, J., Timsit, J.-F., Allenet, B., Bosson, J.-L., & Bedouch, P.
Venue
Critical Care Medicine
Published
2010-12
Volume
38
Issue
12
Pages
2275-2281
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2316494080
Cited by
159
References
5
FWCI
11.21
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated drug dispensing system reduces medication errors in an intensive care setting. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181f8569b
The paper
Chapuis, C., Roustit, M., Bal, G., Schwebel, C., Pansu, P., David-Tchouda, S., Foroni, L., Calop, J., Timsit, J.-F., Allenet, B., Bosson, J.-L., & Bedouch, P. (2010). Automated drug dispensing system reduces medication errors in an intensive care setting. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181f8569b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.