Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: A prospective cohort study*

Cloostermans, Marleen C., van Meulen, Fokke B., Eertman, Carin J., Hom, Harold W., van Putten, Michel J. A. M.·2012·Critical Care Medicine

Abstract

OBJECTIVE: To evaluate the value of continuous electroencephalography in early prognostication in patients treated with hypothermia after cardiac arrest. DESIGN: Prospective cohort study. SETTING: Medical intensive care unit. PATIENTS: Sixty patients admitted to the intensive care unit for therapeutic hypothermia after cardiac arrest. INTERVENTION: None. MEASUREMENTS AND MAIN RESULTS: In all patients, continuous electroencephalogram and daily somatosensory evoked potentials were recorded during the first 5 days of admission or until intensive care unit discharge. Neurological outcomes were based on each patient's best achieved Cerebral Performance Category score within 6 months. Twenty-seven of 56 patients (48%) achieved good neurological outcome (Cerebral Performance Category score 1-2).At 12 hrs after resuscitation, 43% of the patients with good neurological outcome showed continuous, diffuse slow electroencephalogram rhythms, whereas this was never observed in patients with poor outcome.The sensitivity for predicting poor neurological outcome of low-voltage and isoelectric electroencephalogram patterns 24 hrs after resuscitation was 40% (95% confidence interval 19%-64%) with a 100% specificity (confidence interval 86%-100%), whereas the sensitivity and specificity of absent somatosensory evoked potential responses during the first 24 hrs were 24% (confidence interval 10%-44%) and 100% (confidence interval: 87%-100%), respectively. The negative predictive value for poor outcome of low-voltage and isoelectric electroencephalogram patterns was 68% (confidence interval 50%-81%) compared to 55% (confidence interval 40%-60%) for bilateral somatosensory evoked potential absence, both with a positive predictive value of 100% (confidence interval 63%-100% and 59%-100% respectively). Burst-suppression patterns after 24 hrs were also associated with poor neurological outcome, but not inevitably so. CONCLUSIONS: In patients treated with hypothermia, electroencephalogram monitoring during the first 24 hrs after resuscitation can contribute to the prediction of both good and poor neurological outcome. Continuous patterns within 12 hrs predicted good outcome. Isoelectric or low-voltage electroencephalograms after 24 hrs predicted poor outcome with a sensitivity almost two times larger than bilateral absent somatosensory evoked potential responses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e31825b94f0

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 278

Metadata

Authors
Cloostermans, M. C., van Meulen, F. B., Eertman, C. J., Hom, H. W., & van Putten, M. J. A. M.
Venue
Critical Care Medicine
Published
2012-10
Volume
40
Issue
10
Pages
2867-2875
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2154664063
Cited by
278
References
26
FWCI
28.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: A prospective cohort study*. https://app.cochat.ai/papers/10.1097/ccm.0b013e31825b94f0
The paper
Cloostermans, M. C., van Meulen, F. B., Eertman, C. J., Hom, H. W., & van Putten, M. J. A. M. (2012). Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: A prospective cohort study*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e31825b94f0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.