CoChat

Plasma Pharmacokinetics of 3,4-Methylenedioxymethamphetamine After Controlled Oral Administration to Young Adults

Open access
Kolbrich, Erin A, Goodwin, Robert S, Gorelick, David A, Hayes, Robert J, Stein, Elliot A, Huestis, Marilyn A · 2008 · Therapeutic Drug Monitoring
Cited by 124

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

This study examines the plasma pharmacokinetics of 3,4-methylenedioxymethamphetamine (MDMA) and metabolites 4-hydroxy-3-methoxymethamphetamine (HMMA), 3,4-methylenedioxyamphetamine (MDA), and 4-hydroxy-3-methoxyamphetamine (HMA) in young adults for up to 143 hours after drug administration. Seventeen female and male participants (black, white, and Hispanic) received placebo, low (1.0 mg/kg), and high (1.6 mg/kg) oral MDMA doses (comparable to recreational doses) in a double-blind, randomized, balanced, within-subject design while residing on a closed research unit. Doses were separated by 1 week or more. A fully validated two-dimensional gas chromatography/mass spectrometry method simultaneously quantified MDMA, HMMA, MDA, and HMA. Calibration curves were MDA, 1 to 100 ng/mL; HMA, 2.5 to 100 ng/mL; and MDMA and HMMA, 2.5 to 400 ng/mL. Mean +/- standard deviation maximum plasma concentrations (C(max)) of 162.9 +/- 39.8 and 171.9 +/- 79.5 ng/mL were observed for MDMA and HMMA, respectively, after low-dose MDMA. After the high dose, mean MDMA Cmax significantly increased to 291.8 +/- 76.5 ng/mL, whereas mean HMMA C(max) was unchanged at 173.5 +/- 66.3 ng/mL. High intersubject variability in C(max) was observed. Mean MDA C(max) were 8.4 +/- 2.1 (low) and 13.8 +/- 3.8 (high) ng/mL. HMA Cmax were 3.5 +/- 0.4 and 3.9 +/- 0.9 ng/mL after the low and high doses, respectively. AUC infinity displayed similar trends to C(max), demonstrating nonlinear pharmacokinetics. Times of last plasma detection were generally HMA < MDA < MDMA < HMMA. Mean half-lives (t1/2) of MDMA, MDA, and HMMA were approximately 7 to 8 hours, 10.5 to 12.5 hours, and 11.5 to 13.5 hours, respectively. HMA t1/2 showed high variability. Mean MDMA volume of distribution was constant for low and high doses; clearance was significantly higher after the low dose. This study presents MDMA plasma pharmacokinetic data for the first time from blacks and females as well as measurement of HMMA and HMA concentrations after low and high MDMA doses and more frequent and extended plasma sampling than in prior studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ftd.0b013e3181684fa0

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Kolbrich, E. A., Goodwin, R. S., Gorelick, D. A., Hayes, R. J., Stein, E. A., & Huestis, M. A.
Venue
Therapeutic Drug Monitoring
Published
2008-06
Volume
30
Issue
3
Pages
320-332
ISSN
0163-4356 (ISSN-L)
OpenAlex
W1994102540
Cited by
124
References
7
FWCI
17.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.