Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 26

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis

Mellia, Joseph A., Othman, Sammy, Naga, Hani I., Messa, Charles A., Elfanagely, Omar, Byrnes, Yasmeen M., Basta, Marten N., Fischer, John P. · 2020 · Plastic and Reconstructive Surgery - Global Open

Abstract

Background: Within the past decade, poly-4-hydroxybutyrate (P4HB) biosynthetic mesh has been introduced as a potential alternative to traditional biologic and synthetic mesh in ventral hernia repair (VHR). The aim of this study was to systematically assess clinical outcomes with the P4HB in VHR. Methods: A literature search identified all articles published in 2000 involving the use of P4HB in VHR. Descriptive statistics were used to synthesize collective data points, including postoperative outcomes. A pooled analysis of postoperative outcomes was performed using chi-square test and Fisher exact test. Results: Across 7 studies, the P4HB was used in 453 patients. The mean rate of surgical site infection (SSI) was 6.8% (31/453), reoperation 10.7% (30/281), and recurrence 9.1% (41/453). At an average follow-up of 26.8 months, the incidence of recurrence was 10.4% (28/270). Onlay was significantly associated with increased recurrence (14.2% versus 4.4%, P = 0.001). Among sublay placements, there was no difference in recurrence in clean (Center for Disease Control [CDC] 1) or contaminated (CDC >1) wounds (2.7% versus 6.1%, P = 0.585), but contaminated wounds were associated with increased SSI (2.7% versus 15.2%, P = 0.028). Ventral Hernia Working Group grade 2 and 3 did not have different incidences of recurrence (8.0% versus 5.1%, P = 0.526) nor SSI (5.1% versus 14.6%, P = 0.265). Conclusions: Overall, clinical outcomes of the P4HB mesh in VHR are acceptable. The P4HB mesh serves as a reliable alternative to traditional synthetic and biologic mesh across a range of defect characteristics and patient health conditions. Further research is needed to better understand the conditions in which it may provide a clinical benefit over traditional mesh types.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/gox.0000000000003158

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 38

  1. Franz, 2008, The biology of hernia formation., Surg Clin North Am, 88, 1, 10.1016/j.suc.2007.10.007 · DOI · Paper page
  2. Xing, 2013, Early laparotomy wound failure as the mechanism for incisional hernia formation., J Surg Res, 182, e35, 10.1016/j.jss.2012.09.009 · DOI
  3. Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia., Ann Surg, 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
  4. Luijendijk, 2000, A comparison of suture repair with mesh repair for incisional hernia., N Engl J Med, 343, 392, 10.1056/NEJM200008103430603 · DOI · Paper page
  5. Snyder, 2011, Effect of mesh type and position on subsequent abdominal operations after incisional hernia repair., J Am Coll Surg, 212, 496, 10.1016/j.jamcollsurg.2010.12.004 · DOI
  6. Park, 2006, Abdominal wall hernia., Curr Probl Surg, 43, 326, 10.1067/j.cpsurg.2006.02.004 · doi:10.1067/j.cpsurg.2006.02.004
  7. Petro, 2018, A current review of long-acting resorbable meshes in abdominal wall reconstruction., Plast Reconstr Surg, 142, 84S, 10.1097/PRS.0000000000004859 · doi:10.1097/prs.0000000000004859
  8. Darehzereshki, 2014, Biologic versus nonbiologic mesh in ventral hernia repair: a systematic review and meta-analysis., World J Surg, 38, 40, 10.1007/s00268-013-2232-1 · doi:10.1007/s00268-013-2232-1
  9. Burns, 2010, Non-cross-linked porcine acellular dermal matrices for abdominal wall reconstruction., Plast Reconstr Surg, 125, 167, 10.1097/PRS.0b013e3181c2a6ed · doi:10.1097/prs.0b013e3181c2a6ed
  10. Huntington, 2016, Biologic mesh in ventral hernia repair: outcomes, recurrence, and charge analysis., Surgery, 160, 1517, 10.1016/j.surg.2016.07.008 · doi:10.1016/j.surg.2016.07.008
  11. Totten, 2016, Cost of ventral hernia repair using biologic or synthetic mesh., J Surg Res, 203, 459, 10.1016/j.jss.2016.02.040 · doi:10.1016/j.jss.2016.02.040
  12. Stroup, 2000, Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group., JAMA, 283, 2008, 10.1001/jama.283.15.2008 · DOI · Paper page
  13. Stoikes, 2017, Characterization of host response, resorption, and strength properties, and performance in the presence of bacteria for fully absorbable biomaterials for soft tissue repair., Hernia, 21, 771, 10.1007/s10029-017-1638-3 · doi:10.1007/s10029-017-1638-3
  14. Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX Mesh) in a porcine model of hernia repair., ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
  15. Martin, 2013, Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications., J Surg Res, 184, 766, 10.1016/j.jss.2013.03.044 · DOI · Paper page
  16. Williams, 2013, Poly-4-hydroxybutyrate (P4HB): a new generation of resorbable medical devices for tissue repair and regeneration., Biomed Tech (Berl), 58, 439, 10.1515/bmt-2013-0009 · DOI · Paper page
  17. Buell, 2017, Initial experience with biologic polymer scaffold (Poly-4-hydroxybuturate) in complex abdominal wall reconstruction., Ann Surg, 266, 185, 10.1097/SLA.0000000000001916 · DOI
  18. Roth, 2018, Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up., Surg Endosc, 32, 1929, 10.1007/s00464-017-5886-1 · DOI · Paper page
  19. Sahoo, 2017, Early wound morbidity after open ventral hernia repair with biosynthetic or polypropylene mesh., J Am Coll Surg, 225, 472.e1, 10.1016/j.jamcollsurg.2017.07.1067 · DOI · Paper page
  20. Plymale, 2018, Ventral hernia repair with poly-4-hydroxybutyrate mesh., Surg Endosc, 32, 1689, 10.1007/s00464-017-5848-7 · DOI · Paper page
  21. Messa, 2019, When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair., Plast Reconstr Surg Glob Open, 7, e2576, 10.1097/GOX.0000000000002576 · DOI
  22. Pakula, 2020, Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh., Surg Innov, 27, 32, 10.1177/1553350619881066 · doi:10.1177/1553350619881066
  23. Levy, 2020, Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair., Surg Endosc, 13, 12.4
  24. Rognoni, 2020, Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian Hernia Club” registry., Sci Rep, 10, 10706, 10.1038/s41598-020-67821-w · DOI
  25. Weissler, 2017, Development of a clinically actionable incisional hernia risk model after colectomy using the healthcare cost and utilization project., J Am Coll Surg, 225, 274.e1, 10.1016/j.jamcollsurg.2017.04.007 · doi:10.1016/j.jamcollsurg.2017.04.007
  26. Tedelind, 2007, Anti-inflammatory properties of the short-chain fatty acids acetate and propionate: a study with relevance to inflammatory bowel disease., World J Gastroenterol, 13, 2826, 10.3748/wjg.v13.i20.2826 · DOI · Paper page
  27. Wang, 2017, The inflammation induced by lipopolysaccharide can be mitigated by short-chain fatty acid, butyrate, through upregulation of IL-10 in septic shock., Scand J Immunol, 85, 258, 10.1111/sji.12515 · DOI
  28. Ortega, 2012, An evaluation of surgical site infections by wound classification system using the ACS-NSQIP., J Surg Res, 174, 33, 10.1016/j.jss.2011.05.056 · DOI · Paper page
  29. Kummerow Broman, 2017, Hidden morbidity of ventral hernia repair with mesh: as concerning as common bile duct injury?, J Am Coll Surg, 224, 35, 10.1016/j.jamcollsurg.2016.09.016 · doi:10.1016/j.jamcollsurg.2016.09.016
  30. Liang, 2014, Abdominal reoperation and mesh explantation following open ventral hernia repair with mesh., Am J Surg, 208, 670, 10.1016/j.amjsurg.2013.10.024 · DOI
  31. Cobb, 2015, Open retromuscular mesh repair of complex incisional hernia: predictors of wound events and recurrence., J Am Coll Surg, 220, 606, 10.1016/j.jamcollsurg.2014.12.055 · DOI · Paper page
  32. Millikan, 2003, Incisional hernia repair., Surg Clin North Am, 83, 1223, 10.1016/S0039-6109(03)00129-4 · doi:10.1016/s0039-6109(03)00129-4
  33. Molina, 2019, Comparison of the host macrophage response to synthetic and biologic surgical meshes used for ventral hernia repair., J Immunol Regen Med, 3, 13
  34. Sailes, 2010, Synthetic and biological mesh in component separation: a 10-year single institution review., Ann Plast Surg, 64, 696, 10.1097/SAP.0b013e3181dc8409 · DOI
  35. Albino, 2013, Does mesh location matter in abdominal wall reconstruction? A systematic review of the literature and a summary of recommendations., Plast Reconstr Surg, 132, 1295, 10.1097/PRS.0b013e3182a4c393 · DOI · Paper page
  36. Shankaran, 2011, A review of available prosthetics for ventral hernia repair., Ann Surg, 253, 16, 10.1097/SLA.0b013e3181f9b6e6 · DOI · Paper page
  37. Breuing, 2010, Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair., J Surg, 148, 544
  38. Itani, 2012, Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study., Surgery, 152, 498, 10.1016/j.surg.2012.04.008 · DOI · Paper page

Cited by

See all 26

Metadata

Authors
Mellia, J. A., Othman, S., Naga, H. I., Messa, C. A., Elfanagely, O., Byrnes, Y. M., Basta, M. N., & Fischer, J. P.
Affiliations
  • Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pa.
  • Department of Plastic and Reconstructive Surgery, Brown University, Providence, R.I.
Venue
Plastic and Reconstructive Surgery - Global Open
Published
2020-12
Volume
8
Issue
12
Pages
e3158
ISSN
2169-7574
Cited by
26
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis. https://app.cochat.ai/papers/10.1097/gox.0000000000003158
The paper
Mellia, J. A., Othman, S., Naga, H. I., Messa, C. A., Elfanagely, O., Byrnes, Y. M., Basta, M. N., & Fischer, J. P. (2020). Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis. Plastic and Reconstructive Surgery - Global Open. https://doi.org/10.1097/gox.0000000000003158

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.