Abstract
Background: Within the past decade, poly-4-hydroxybutyrate (P4HB) biosynthetic mesh has been introduced as a potential alternative to traditional biologic and synthetic mesh in ventral hernia repair (VHR). The aim of this study was to systematically assess clinical outcomes with the P4HB in VHR. Methods: A literature search identified all articles published in 2000 involving the use of P4HB in VHR. Descriptive statistics were used to synthesize collective data points, including postoperative outcomes. A pooled analysis of postoperative outcomes was performed using chi-square test and Fisher exact test. Results: Across 7 studies, the P4HB was used in 453 patients. The mean rate of surgical site infection (SSI) was 6.8% (31/453), reoperation 10.7% (30/281), and recurrence 9.1% (41/453). At an average follow-up of 26.8 months, the incidence of recurrence was 10.4% (28/270). Onlay was significantly associated with increased recurrence (14.2% versus 4.4%, P = 0.001). Among sublay placements, there was no difference in recurrence in clean (Center for Disease Control [CDC] 1) or contaminated (CDC >1) wounds (2.7% versus 6.1%, P = 0.585), but contaminated wounds were associated with increased SSI (2.7% versus 15.2%, P = 0.028). Ventral Hernia Working Group grade 2 and 3 did not have different incidences of recurrence (8.0% versus 5.1%, P = 0.526) nor SSI (5.1% versus 14.6%, P = 0.265). Conclusions: Overall, clinical outcomes of the P4HB mesh in VHR are acceptable. The P4HB mesh serves as a reliable alternative to traditional synthetic and biologic mesh across a range of defect characteristics and patient health conditions. Further research is needed to better understand the conditions in which it may provide a clinical benefit over traditional mesh types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In a systematic review and pooled analysis by Mellia et al9 on outcomes of the Phasix mesh following ventral hernia repair, a recurrence rate of 28/270 (10.4%) was observed after 26.8 months, with significantly more frequent recurrences in the onlay position versus the sublay position (14.2% vs 4.4%).”
From Five-Year Follow-Up of a Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) in VHWG Grade 3 Incisional Hernia Repair (2023) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rayyan-a web and mobile app for systematic reviews.
Ouzzani, M., Hammady, H., Fedorowicz, Z., & Elmagarmid, A. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0384-4 · Cited by 26,092
Research works printed but not linked: 38
- Franz, 2008, The biology of hernia formation., Surg Clin North Am, 88, 1, 10.1016/j.suc.2007.10.007 · DOI · Paper page
- Xing, 2013, Early laparotomy wound failure as the mechanism for incisional hernia formation., J Surg Res, 182, e35, 10.1016/j.jss.2012.09.009 · DOI
- Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia., Ann Surg, 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
- Luijendijk, 2000, A comparison of suture repair with mesh repair for incisional hernia., N Engl J Med, 343, 392, 10.1056/NEJM200008103430603 · DOI · Paper page
- Snyder, 2011, Effect of mesh type and position on subsequent abdominal operations after incisional hernia repair., J Am Coll Surg, 212, 496, 10.1016/j.jamcollsurg.2010.12.004 · DOI
- Park, 2006, Abdominal wall hernia., Curr Probl Surg, 43, 326, 10.1067/j.cpsurg.2006.02.004 · doi:10.1067/j.cpsurg.2006.02.004
- Petro, 2018, A current review of long-acting resorbable meshes in abdominal wall reconstruction., Plast Reconstr Surg, 142, 84S, 10.1097/PRS.0000000000004859 · doi:10.1097/prs.0000000000004859
- Darehzereshki, 2014, Biologic versus nonbiologic mesh in ventral hernia repair: a systematic review and meta-analysis., World J Surg, 38, 40, 10.1007/s00268-013-2232-1 · doi:10.1007/s00268-013-2232-1
- Burns, 2010, Non-cross-linked porcine acellular dermal matrices for abdominal wall reconstruction., Plast Reconstr Surg, 125, 167, 10.1097/PRS.0b013e3181c2a6ed · doi:10.1097/prs.0b013e3181c2a6ed
- Huntington, 2016, Biologic mesh in ventral hernia repair: outcomes, recurrence, and charge analysis., Surgery, 160, 1517, 10.1016/j.surg.2016.07.008 · doi:10.1016/j.surg.2016.07.008
- Totten, 2016, Cost of ventral hernia repair using biologic or synthetic mesh., J Surg Res, 203, 459, 10.1016/j.jss.2016.02.040 · doi:10.1016/j.jss.2016.02.040
- Stroup, 2000, Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group., JAMA, 283, 2008, 10.1001/jama.283.15.2008 · DOI · Paper page
- Stoikes, 2017, Characterization of host response, resorption, and strength properties, and performance in the presence of bacteria for fully absorbable biomaterials for soft tissue repair., Hernia, 21, 771, 10.1007/s10029-017-1638-3 · doi:10.1007/s10029-017-1638-3
- Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (Poly-4-hydroxybutyrate-PHASIX Mesh) in a porcine model of hernia repair., ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
- Martin, 2013, Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications., J Surg Res, 184, 766, 10.1016/j.jss.2013.03.044 · DOI · Paper page
- Williams, 2013, Poly-4-hydroxybutyrate (P4HB): a new generation of resorbable medical devices for tissue repair and regeneration., Biomed Tech (Berl), 58, 439, 10.1515/bmt-2013-0009 · DOI · Paper page
- Buell, 2017, Initial experience with biologic polymer scaffold (Poly-4-hydroxybuturate) in complex abdominal wall reconstruction., Ann Surg, 266, 185, 10.1097/SLA.0000000000001916 · DOI
- Roth, 2018, Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up., Surg Endosc, 32, 1929, 10.1007/s00464-017-5886-1 · DOI · Paper page
- Sahoo, 2017, Early wound morbidity after open ventral hernia repair with biosynthetic or polypropylene mesh., J Am Coll Surg, 225, 472.e1, 10.1016/j.jamcollsurg.2017.07.1067 · DOI · Paper page
- Plymale, 2018, Ventral hernia repair with poly-4-hydroxybutyrate mesh., Surg Endosc, 32, 1689, 10.1007/s00464-017-5848-7 · DOI · Paper page
- Messa, 2019, When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair., Plast Reconstr Surg Glob Open, 7, e2576, 10.1097/GOX.0000000000002576 · DOI
- Pakula, 2020, Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh., Surg Innov, 27, 32, 10.1177/1553350619881066 · doi:10.1177/1553350619881066
- Levy, 2020, Poly-4-hydroxybutyrate (Phasix™) mesh onlay in complex abdominal wall repair., Surg Endosc, 13, 12.4
- Rognoni, 2020, Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian Hernia Club” registry., Sci Rep, 10, 10706, 10.1038/s41598-020-67821-w · DOI
- Weissler, 2017, Development of a clinically actionable incisional hernia risk model after colectomy using the healthcare cost and utilization project., J Am Coll Surg, 225, 274.e1, 10.1016/j.jamcollsurg.2017.04.007 · doi:10.1016/j.jamcollsurg.2017.04.007
- Tedelind, 2007, Anti-inflammatory properties of the short-chain fatty acids acetate and propionate: a study with relevance to inflammatory bowel disease., World J Gastroenterol, 13, 2826, 10.3748/wjg.v13.i20.2826 · DOI · Paper page
- Wang, 2017, The inflammation induced by lipopolysaccharide can be mitigated by short-chain fatty acid, butyrate, through upregulation of IL-10 in septic shock., Scand J Immunol, 85, 258, 10.1111/sji.12515 · DOI
- Ortega, 2012, An evaluation of surgical site infections by wound classification system using the ACS-NSQIP., J Surg Res, 174, 33, 10.1016/j.jss.2011.05.056 · DOI · Paper page
- Kummerow Broman, 2017, Hidden morbidity of ventral hernia repair with mesh: as concerning as common bile duct injury?, J Am Coll Surg, 224, 35, 10.1016/j.jamcollsurg.2016.09.016 · doi:10.1016/j.jamcollsurg.2016.09.016
- Liang, 2014, Abdominal reoperation and mesh explantation following open ventral hernia repair with mesh., Am J Surg, 208, 670, 10.1016/j.amjsurg.2013.10.024 · DOI
- Cobb, 2015, Open retromuscular mesh repair of complex incisional hernia: predictors of wound events and recurrence., J Am Coll Surg, 220, 606, 10.1016/j.jamcollsurg.2014.12.055 · DOI · Paper page
- Millikan, 2003, Incisional hernia repair., Surg Clin North Am, 83, 1223, 10.1016/S0039-6109(03)00129-4 · doi:10.1016/s0039-6109(03)00129-4
- Molina, 2019, Comparison of the host macrophage response to synthetic and biologic surgical meshes used for ventral hernia repair., J Immunol Regen Med, 3, 13
- Sailes, 2010, Synthetic and biological mesh in component separation: a 10-year single institution review., Ann Plast Surg, 64, 696, 10.1097/SAP.0b013e3181dc8409 · DOI
- Albino, 2013, Does mesh location matter in abdominal wall reconstruction? A systematic review of the literature and a summary of recommendations., Plast Reconstr Surg, 132, 1295, 10.1097/PRS.0b013e3182a4c393 · DOI · Paper page
- Shankaran, 2011, A review of available prosthetics for ventral hernia repair., Ann Surg, 253, 16, 10.1097/SLA.0b013e3181f9b6e6 · DOI · Paper page
- Breuing, 2010, Incisional ventral hernias: review of the literature and recommendations regarding the grading and technique of repair., J Surg, 148, 544
- Itani, 2012, Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study., Surgery, 152, 498, 10.1016/j.surg.2012.04.008 · DOI · Paper page
Cited by
Van den Dop, L. M., Van Rooijen, M. M. J., Tollens, T., Jørgensen, L. N., De Vries-Reilingh, T. S., Piessen, G., Köckerling, F., Miserez, M., Dean, M., Berrevoet, F., et al. (2023) · Annals of Surgery Open · doi:10.1097/as9.0000000000000366 · Cited by 21
Metadata
- Authors
- Mellia, J. A., Othman, S., Naga, H. I., Messa, C. A., Elfanagely, O., Byrnes, Y. M., Basta, M. N., & Fischer, J. P.
- Affiliations
- Division of Plastic Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pa.
- Department of Plastic and Reconstructive Surgery, Brown University, Providence, R.I.
- Venue
- Plastic and Reconstructive Surgery - Global Open
- Published
- 2020-12
- Volume
- 8
- Issue
- 12
- Pages
- e3158
- ISSN
- 2169-7574
- Cited by
- 26
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis. https://app.cochat.ai/papers/10.1097/gox.0000000000003158
- The paper
- Mellia, J. A., Othman, S., Naga, H. I., Messa, C. A., Elfanagely, O., Byrnes, Y. M., Basta, M. N., & Fischer, J. P. (2020). Outcomes of Poly-4-hydroxybutyrate Mesh in Ventral Hernia Repair: A Systematic Review and Pooled Analysis. Plastic and Reconstructive Surgery - Global Open. https://doi.org/10.1097/gox.0000000000003158
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.