CoChat

Comparisons of auscultatory hybrid and automated sphygmomanometers with mercury sphygmomanometry in hypertensive and normotensive pregnant women: parallel validation studies

Davis, Gregory K., Roberts, Lynne M., Mangos, George J., Brown, Mark A. · 2015 · Journal of Hypertension
Cited by 29

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To find a suitable replacement for mercury sphygmomanometry to measure blood pressure (BP) accurately in normal and hypertensive pregnancy. METHODS: Two parallel validation studies were carried out in 340 pregnant women, 170 with a hypertensive disorder and 170 normotensive women. An auscultatory hybrid sphygmomanometer, A&D UM-101, and a professional automated oscillometric device for office and clinic use, Omron HEM-907, were tested. Using a modified British Hypertension Society (BHS) Protocol, nine sequential BP recordings were taken alternating between the mercury sphygmomanometer and the study device. The first readings for each device were discarded, and three differences between mercury and study device were calculated for each woman for SBP and DBP. Main outcome measures were the percentages of BP readings that were within 5, 10 and 15 mmHg absolute difference from mercury sphygmomanometry. RESULTS: Women in both studies were an average of 34 weeks' gestation and of similar ethnicity, age and BMI. In hypertensive women, 29% had preeclampsia and 73% were receiving antihypertensives. Amongst hypertensive women, SBP was within 5 mmHg of mercury BP in 94% of readings with the auscultatory device and 75% with the automated device (P = 0.021); DBP was within 5 mmHg in 97 and 61% readings, respectively (P = 0.001). Results were similar amongst normotensive pregnant women. Both devices achieved an A/A rating according to the BHS protocol. CONCLUSION: The auscultatory hybrid sphygmomanometer is more accurate than the automated oscillometric device in pregnancy, specifically in hypertensive pregnancies. It is an acceptable replacement for mercury sphygmomanometry in pregnancy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000000420

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 29

Metadata

Authors
Davis, G. K., Roberts, L. M., Mangos, G. J., & Brown, M. A.
Venue
Journal of Hypertension
Published
2015-03
Volume
33
Issue
3
Pages
499-506
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2095316572
Cited by
29
References
3
FWCI
2.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparisons of auscultatory hybrid and automated sphygmomanometers with mercury sphygmomanometry in hypertensive and normotensive pregnant women: parallel validation studies. https://app.cochat.ai/papers/10.1097/hjh.0000000000000420
The paper
Davis, G. K., Roberts, L. M., Mangos, G. J., & Brown, M. A. (2015). Comparisons of auscultatory hybrid and automated sphygmomanometers with mercury sphygmomanometry in hypertensive and normotensive pregnant women: parallel validation studies. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000420

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.