Agreement between ambulatory, home, and office blood pressure variability
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Objective Ambulatory, home, and office blood pressure (BP) variability are often treated as a single entity. Our aim was to assess the agreement between these three methods for measuring BP variability. Methods Twenty-four-hour ambulatory BP monitoring, 28 home BP measurements, and eight office BP measurements were performed on 461 population-based or hypertensive participants. Five variability indices were calculated for all measurement methods: SD, coefficient of variation, maximum-minimum difference, variability independent of the mean, and average real variability. Pearson's correlation coefficients were calculated for indices measured with different methods. The agreement between different measurement methods on the diagnoses of extreme BP variability (participants in the highest decile of variability) was assessed with kappa (κ) coefficients. Results SBP/DBP variability was greater in daytime (coefficient of variation: 9.8 ± 2.9/11.9 ± 3.6) and night-time ambulatory measurements (coefficient of variation: 8.6 ± 3.4/12.1 ± 4.5) than in home (coefficient of variation: 4.4 ± 1.8/4.7 ± 1.9) and office (coefficient of variation: 4.6 ± 2.4/5.2 ± 2.6) measurements (P Conclusion Shorter-term and longer-term BP variability assessed by different methods of BP measurement seem to correlate only weakly with each other. Our study suggests that BP variability measured by different methods and timeframes may reflect different phenomena, not a single entity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of note, although all types of BPV have a certain degree of clinical relevance and prognostic value, the association between the indices of different types of BPV, as well as their agreement in detecting individuals with high BPV, is moderate87,88.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [87]
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Lim, S. S., Vos, T., Flaxman, A. D., Danaei, G., Shibuya, K., Adair-Rohani, H., AlMazroa, M. A., Amann, M., Anderson, H. R., Andrews, K. G., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61766-8 · Cited by 11,805 · cited 1×
“H igh blood pressure (BP) is a well known risk factor for cardiovascular morbidity and mortality [1,2].”
BackgroundRothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784 · cited 3×
“In the Anglo-Scandinavian Cardiac Outcomes Trial-Blood Pressure Lowering Arm study, visit-to-visit variability of SBP was related to age, female sex, diabetes, and peripheral vascular disease, whereas its effect on stroke risk was greatest at young ages [5].”
BackgroundRapsomaniki, E., Timmis, A., George, J., Pujades-Rodriguez, M., Shah, A. D., Denaxas, S., White, I. R., Caulfield, M. J., Deanfield, J. E., Smeeth, L., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60685-1 · Cited by 1,643 · cited 1×
“H igh blood pressure (BP) is a well known risk factor for cardiovascular morbidity and mortality [1,2].”
BackgroundAssessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Poulter, N. R., & Sever, P. S. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70066-1 · Cited by 690 · cited 1×
“VIM is a transformation of SD that is defined to be uncorrelated with average levels [5,20,21].”
Pickering, T. G. (1982) · JAMA · doi:10.1001/jama.247.7.992 · Cited by 526
A reliable index for the prognostic significance of blood pressure variability
Mena, L., Pintos, S., Queipo, N. V., Aizpúrua, J. A., Maestre, G., & Sulbarán, T. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160205.81652.5a · Cited by 523 · cited 2×
“These indices define BP variability on a different basis, causing further discrepancies in the interpretation of BP variability [14].”
BackgroundHansen, T. W., Thijs, L., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.140798 · Cited by 480 · cited 1×
“ARV is the average of the differences between consecutive BP measurements [5,6,14].”
BackgroundMuntner, P., Shimbo, D., Tonelli, M., Reynolds, K., Arnett, D. K., & Oparil, S. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162255 · Cited by 440 · cited 1×
“C-reactive protein, a history of myocardial infarction or stroke, and the use of antihypertensive medication [36].”
Background
Research works printed but not linked: 1
- Nasothimiou, 2011, Blood pressure variability assessed by clinic, home and ambulatory measurements abstract., J Hypertens, 29, e448
Cited by
Diabetes and hypertension: a position statement by the American Diabetes Association
de Boer, I. H., Bangalore, S., Benetos, A., Davis, A. M., Michos, E. D., Muntner, P., Rossing, P., Zoungas, S., & Bakris, G. (2017) · Diabetes Care · doi:10.2337/dci17-0026 · Cited by 714
“Furthermore, evidence suggests home blood pressure monitoring is as accurate as 24-h ambulatory blood pressure monitoring (96,97) and may better correlate with ASCVD risk than office measurements (98,99).”
BackgroundBlood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Parati, G., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Castiglioni, P., Stergiou, G. S., Mancia, G., Asayama, K., Asmar, R., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003363 · Cited by 220
Self-citationHypertension, Blood Pressure Variability, and Target Organ Lesion
Irigoyen, M. C., Angelis, K. D., dos Santos, F., Dartora, D. R., Rodrigues, B., & Consolim‐Colombo, F. M. (2016) · Current Hypertension Reports · doi:10.1007/s11906-016-0642-9 · Cited by 93
Giorno, R. D., Balestra, L., Heiniger, P. S., & Gabutti, L. (2019) · Medicine · doi:10.1097/md.0000000000016347 · Cited by 50
Metadata
- Authors
- Juhanoja, E. P., Niiranen, T. J., Johansson, J. K., Puukka, P. J., & Jula, A. M.
- Affiliations
- Turku University Hospital (FI)
- Corresponding author
- Juhanoja, Eeva P.
- Venue
- Journal of Hypertension
- Published
- 2016-01
- Volume
- 34
- Issue
- 1
- Pages
- 61-67
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2342649031
- Cited by
- 36
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 6 · 2021: 3 · 2020: 2 · 2019: 6 · 2018: 4 · 2017: 5 · 2016: 3
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) (submittedVersion)
- Funders
- Kela
- Varsinais-Suomen Sairaanhoitopiiri
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- blood pressure variability, ambulatory blood pressure monitoring, home blood pressure monitoring, office blood pressure measurement, measurement agreement, hypertension, systolic blood pressure, diastolic blood pressure, coefficient of variation, variability indices
- MeSH terms
- Adult, Blood Pressure, Diastole, Female, Humans, Hypertension, Male, Middle Aged, Office Visits, Self Care, Systole, Time Factors, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Agreement between ambulatory, home, and office blood pressure variability. https://app.cochat.ai/papers/10.1097/hjh.0000000000000772
- The paper
- Juhanoja, E. P., Niiranen, T. J., Johansson, J. K., Puukka, P. J., & Jula, A. M. (2016). Agreement between ambulatory, home, and office blood pressure variability. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000772
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.