Agreement between ambulatory, home, and office blood pressure variability
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Objective Ambulatory, home, and office blood pressure (BP) variability are often treated as a single entity. Our aim was to assess the agreement between these three methods for measuring BP variability. Methods Twenty-four-hour ambulatory BP monitoring, 28 home BP measurements, and eight office BP measurements were performed on 461 population-based or hypertensive participants. Five variability indices were calculated for all measurement methods: SD, coefficient of variation, maximum-minimum difference, variability independent of the mean, and average real variability. Pearson's correlation coefficients were calculated for indices measured with different methods. The agreement between different measurement methods on the diagnoses of extreme BP variability (participants in the highest decile of variability) was assessed with kappa (κ) coefficients. Results SBP/DBP variability was greater in daytime (coefficient of variation: 9.8 ± 2.9/11.9 ± 3.6) and night-time ambulatory measurements (coefficient of variation: 8.6 ± 3.4/12.1 ± 4.5) than in home (coefficient of variation: 4.4 ± 1.8/4.7 ± 1.9) and office (coefficient of variation: 4.6 ± 2.4/5.2 ± 2.6) measurements (P Conclusion Shorter-term and longer-term BP variability assessed by different methods of BP measurement seem to correlate only weakly with each other. Our study suggests that BP variability measured by different methods and timeframes may reflect different phenomena, not a single entity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of note, although all types of BPV have a certain degree of clinical relevance and prognostic value, the association between the indices of different types of BPV, as well as their agreement in detecting individuals with high BPV, is moderate87,88.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [87]
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Lim, S. S., Vos, T., Flaxman, A. D., Danaei, G., Shibuya, K., Adair-Rohani, H., AlMazroa, M. A., Amann, M., Anderson, H. R., Andrews, K. G., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61766-8 · Cited by 11,805 · cited 1×
“H igh blood pressure (BP) is a well known risk factor for cardiovascular morbidity and mortality [1,2].”
BackgroundRothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784 · cited 3×
“In the Anglo-Scandinavian Cardiac Outcomes Trial-Blood Pressure Lowering Arm study, visit-to-visit variability of SBP was related to age, female sex, diabetes, and peripheral vascular disease, whereas its effect on stroke risk was greatest at young ages [5].”
BackgroundRapsomaniki, E., Timmis, A., George, J., Pujades-Rodriguez, M., Shah, A. D., Denaxas, S., White, I. R., Caulfield, M. J., Deanfield, J. E., Smeeth, L., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60685-1 · Cited by 1,643 · cited 1×
“H igh blood pressure (BP) is a well known risk factor for cardiovascular morbidity and mortality [1,2].”
BackgroundAssessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Poulter, N. R., & Sever, P. S. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70066-1 · Cited by 690 · cited 1×
“VIM is a transformation of SD that is defined to be uncorrelated with average levels [5,20,21].”
Pickering, T. G. (1982) · JAMA · doi:10.1001/jama.247.7.992 · Cited by 526
A reliable index for the prognostic significance of blood pressure variability
Mena, L., Pintos, S., Queipo, N. V., Aizpúrua, J. A., Maestre, G., & Sulbarán, T. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000160205.81652.5a · Cited by 523 · cited 2×
“These indices define BP variability on a different basis, causing further discrepancies in the interpretation of BP variability [14].”
BackgroundHansen, T. W., Thijs, L., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.140798 · Cited by 480 · cited 1×
“ARV is the average of the differences between consecutive BP measurements [5,6,14].”
BackgroundMuntner, P., Shimbo, D., Tonelli, M., Reynolds, K., Arnett, D. K., & Oparil, S. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162255 · Cited by 440 · cited 1×
“C-reactive protein, a history of myocardial infarction or stroke, and the use of antihypertensive medication [36].”
BackgroundO'Brien, E. T., Mee, F. I., Atkins, N., & Thomas (1996) · PubMed · Cited by 409
Kikuya, M., Ohkubo, T., Metoki, H., Asayama, K., Hara, A., Obara, T., Inoue, R., Hoshi, H., Hashimoto, J., Totsune, K., et al. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.104620 · Cited by 402 · cited 1×
“VIM is a transformation of SD that is defined to be uncorrelated with average levels [5,20,21].”
BackgroundMancia, G., Bombelli, M., Facchetti, R., Madotto, F., Corrao, G., Trevano, F. Q., Grassi, G., & Sega, R. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.088708 · Cited by 376
Ambulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317 · cited 1×
“Ambulatory BP, on the other hand, measures shorter-term variability and reflects daytime and night-time BP during normal activities [10].”
BackgroundJohansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.178657 · Cited by 240
Self-citationMancia, G., Facchetti, R., Parati, G., & Zanchetti, A. (2012) · Circulation · doi:10.1161/circulationaha.112.107565 · Cited by 156
Blood pressure variability: Its measurement and significance in hypertension
Parati, G., Faini, A., & Valentini, M. (2006) · Current Hypertension Reports · doi:10.1007/s11906-006-0051-6 · Cited by 152
Factors That Affect Blood Pressure Variability A Community-Based Study in Ohasama, Japan
Imai, Y. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00277-x · Cited by 143 · cited 1×
“In addition to diminished baroreflex function, increased stiffness and decreased compliance of large arteries have been shown to account for longer-term BP variability [32,33].”
BackgroundWei, F.-F., Li, Y., Zhang, L., Xu, T.-Y., Ding, F.-H., Wang, J.-G., & Staessen, J. A. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02681 · Cited by 142 · cited 1×
“with 256 untreated Chinese participants also investigated the associations between beat-to-beat, ambulatory, and home measurement using VIM, MMD, and ARV as variability indices [25].”
MethodVirtanen, R., Jula, A., Salminen, J. K., Voipio-Pulkki, L.-M., Helenius, H., Kuusela, T., & Airaksinen, J. (2003) · Psychosomatic Medicine · doi:10.1097/01.psy.0000088760.65046.cf · Cited by 140 · cited 1×
“An individual’s mood is also a determinant of shorter-term BP variability; anger and anxiety are associated with significant increases [30,31] whereas happiness is associated with decreases in BP variability [31].”
BackgroundSelf-citationHome Blood Pressure Variability as Cardiovascular Risk Factor in the Population of Ohasama
Asayama, K., Kikuya, M., Schutte, R., Thijs, L., Hosaka, M., Satoh, M., Hara, A., Obara, T., Inoue, R., Metoki, H., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00138 · Cited by 131 · cited 2×
“There is some evidence that other indices such as coefficient of variation, maximum–minimum difference (MMD), variability independent of the mean (VIM), and average real variability (ARV) could be more informative [15].”
BackgroundMultiple Clinic and Home Blood Pressure Measurements Versus Ambulatory Blood Pressure Monitoring
Jula, A., Puukka, P., & Karanko, H. (1999) · Hypertension · doi:10.1161/01.hyp.34.2.261 · Cited by 122 · cited 2×
“43 DBP 18, the reading was excluded [17].”
BackgroundSelf-citationSchutte, R., Thijs, L., Liu, Y.-P., Asayama, K., Jin, Y., Odili, A., Gu, Y.-M., Kuznetsova, T., Jacobs, L., & Staessen, J. A. (2012) · Hypertension · doi:10.1161/hypertensionaha.112.202143 · Cited by 121
Blood pressure variability assessed by home measurements: a systematic review
Stergiou, G. S., Ntineri, A., Kollias, A., Ohkubo, T., Imai, Y., & Parati, G. (2014) · Hypertension Research · doi:10.1038/hr.2014.2 · Cited by 102
Does Blood Pressure Variability Modulate Cardiovascular Risk?
Rothwell, P. M. (2011) · Current Hypertension Reports · doi:10.1007/s11906-011-0201-3 · Cited by 78
Kato, T., Kikuya, M., Ohkubo, T., Satoh, M., Hara, A., Obara, T., Metoki, H., Asayama, K., Hirose, T., Inoue, R., et al. (2010) · American Journal of Hypertension · doi:10.1038/ajh.2010.94 · Cited by 63 · cited 1×
“Increased day-to-day variability of home BP, defined as SD and coefficient of variation of home BP, was associated with older age, female sex, higher SBP level, and alcohol consumption in a Japanese unselected population [34].”
BackgroundJohansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833b6c8a · Cited by 48 · cited 1×
“In the Finnish Finn-Home study, older age, higher BP, and excessive alcohol use were associated with higher day-to-day BP variability [35].”
BackgroundSelf-citationTaylor, R., Chidley, K., Goodwin, J., Broeders, M., & Kirby, B. (1993) · Journal of Hypertension · doi:10.1097/00004872-199311000-00016 · Cited by 41 · cited 2×
“Blood pressure measurements We recorded ambulatory BP with an auscultatory device (Suntech Accutracker II; Suntech Medical Instruments, Raleigh, North Carolina, USA) that was validated according to the Association for the Advancement of Medical Instrumentation and British Hypertension Society protocols [18].”
MethodStergiou, G. S., & Parati, G. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.172924 · Cited by 37 · cited 1×
“The concept of BP variability is ambiguous, because BP can be measured using different methods, protocols, timings, and indices [16].”
MethodBrueren, M. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00125-8 · Cited by 35 · cited 1×
“One challenge in assessing BP variability is that the repeatability of measurements is often poor with all measurement methods [37].”
BackgroundImai, Y., Ohkubo, T., Tsuji, I., Hozawa, A., Nagai, K., Kikuya, M., Aihara, A., Sekino, M., Michimata, M., Matsubara, M., et al. (1999) · Hypertension Research · doi:10.1291/hypres.22.261 · Cited by 34 · cited 1×
“14) in the untreated participants and comparable with those found in our study [24].”
ResultLow correlation between visit-to-visit variability and 24-h variability of blood pressure
Muntner, P., Shimbo, D., Diaz, K. M., Newman, J. D., Sloan, R. P., & Schwartz, J. E. (2013) · Hypertension Research · doi:10.1038/hr.2013.58 · Cited by 28 · cited 1×
“13 between ARV of day–night and visit-to-visit variability, respectively [26].”
BackgroundMechanisms Concerned with Blood Pressure Variability Throughout the Day
Conway, J., Boon, N. A., Jones, J. V., & Sleight, P. (1985) · Clinical and Experimental Hypertension · doi:10.3109/10641968509073534 · Cited by 25 · cited 1×
“In addition to diminished baroreflex function, increased stiffness and decreased compliance of large arteries have been shown to account for longer-term BP variability [32,33].”
BackgroundDeterminants of ambulatory blood pressure response to physical activity
Cavelaars, M., Tulen, J. H. M., van Bemmel, J. H., ter Borg, M. J., Mulder, P. G. H., & van den Meiracker, A. H. (2002) · Journal of Hypertension · doi:10.1097/00004872-200210000-00020 · Cited by 18 · cited 1×
“[29], the effect of physical activity was 11.”
BackgroundBehavioral Determinants of 24-Hour Blood Pressure Patterns in Borderline Hypertension
Pickering, T. G., Harshfield, G. A., Blank, S. G., James, G. D., Laragh, J. H., Clark, L. A., Denby, L., & Pregibon, D. (1986) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-198608005-00017 · Cited by 13 · cited 1×
“An individual’s mood is also a determinant of shorter-term BP variability; anger and anxiety are associated with significant increases [30,31] whereas happiness is associated with decreases in BP variability [31].”
Background
Research works printed but not linked: 1
- Nasothimiou, 2011, Blood pressure variability assessed by clinic, home and ambulatory measurements abstract., J Hypertens, 29, e448
Cited by
Diabetes and hypertension: a position statement by the American Diabetes Association
de Boer, I. H., Bangalore, S., Benetos, A., Davis, A. M., Michos, E. D., Muntner, P., Rossing, P., Zoungas, S., & Bakris, G. (2017) · Diabetes Care · doi:10.2337/dci17-0026 · Cited by 714
“Furthermore, evidence suggests home blood pressure monitoring is as accurate as 24-h ambulatory blood pressure monitoring (96,97) and may better correlate with ASCVD risk than office measurements (98,99).”
BackgroundBlood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Parati, G., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Castiglioni, P., Stergiou, G. S., Mancia, G., Asayama, K., Asmar, R., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003363 · Cited by 220
Self-citationHypertension, Blood Pressure Variability, and Target Organ Lesion
Irigoyen, M. C., Angelis, K. D., dos Santos, F., Dartora, D. R., Rodrigues, B., & Consolim‐Colombo, F. M. (2016) · Current Hypertension Reports · doi:10.1007/s11906-016-0642-9 · Cited by 93
Giorno, R. D., Balestra, L., Heiniger, P. S., & Gabutti, L. (2019) · Medicine · doi:10.1097/md.0000000000016347 · Cited by 50
Metadata
- Authors
- Juhanoja, E. P., Niiranen, T. J., Johansson, J. K., Puukka, P. J., & Jula, A. M.
- Affiliations
- Turku University Hospital (FI)
- Corresponding author
- Juhanoja, Eeva P.
- Venue
- Journal of Hypertension
- Published
- 2016-01
- Volume
- 34
- Issue
- 1
- Pages
- 61-67
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2342649031
- Semantic Scholar
- 94c9022ac42fe60522598e001dfa64ebd7e28bd3
- Cited by
- 36
- References
- 35
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 6 · 2021: 3 · 2020: 2 · 2019: 6 · 2018: 4 · 2017: 5 · 2016: 3
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Hypertension (publishedVersion)
- PubMed (publishedVersion)
- STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) (submittedVersion)
- Funders
- Kela
- Varsinais-Suomen Sairaanhoitopiiri
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- blood pressure variability, ambulatory blood pressure monitoring, home blood pressure monitoring, office blood pressure measurement, measurement agreement, hypertension, systolic blood pressure, diastolic blood pressure, coefficient of variation, variability indices
- MeSH terms
- Adult, Blood Pressure, Diastole, Female, Humans, Hypertension, Male, Middle Aged, Office Visits, Self Care, Systole, Time Factors, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.