CoChat

Current assessment of pulse wave velocity: comprehensive review of validation studies

Milan, Alberto, Zocaro, Gaia, Leone, Dario, Tosello, Francesco, Buraioli, Irene, Schiavone, Domenica, Veglio, Franco · 2019 · Journal of Hypertension
Cited by 236

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Carotid-femoral pulse wave velocity (PWV) is considered the gold standard for arterial stiffness assessment in clinical practice. A large number of devices to measure PWV have been developed and validated. We reviewed different validation studies of PWV estimation techniques and assessed their conformity to the Artery Society Guidelines and the American Heart Association recommendations. METHODS: Pubmed and Medline (1995-2017) were searched to identify PWV validation studies. Of the 96 article retrieved, 26 met the inclusion criteria. RESULTS: Several devices had been developed and validated to noninvasively measure arterial stiffness, using applanation tonometry (SphygmoCor, PulsePen), piezoelectric mechanotransducers (Complior), cuff-based oscillometry (Arteriograph, Vicorder and Mobil-O-Graph), photodiode sensors (pOpmètre) and devices assessing brachial-ankle pulse wave velocity and cardiac-ankle PWV. Ultrasound technique and MRI remain confined to clinical research. Good agreement was found with the Artery Society Guidelines. Two studies (Complior, SphygmoCor Xcel) showed best adherence with the guidelines. In Arteriograph, MRI, ultrasound and SphygmoCor Xcel validation studies sample size was smaller than the minimum suggested by the guidelines. High discrepancies between devices were shown in distance estimation: in two studies (Arteriograph, Complior) path length was estimated in conformity to the guidelines. Transit time was calculated using the intersecting tangent method, but in two studies (Vicorder, pOpmètre) best agreement was found using the maximum of the second derivative. Six studies reached the accuracy level 'excellent' defined in the Artery guidelines. CONCLUSION: Method to assess transit time and path length need validation in larger populations. Further studies are required in different risk population to implement clinical applicability of every device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000002081

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 236

Metadata

Authors
Milan, A., Zocaro, G., Leone, D., Tosello, F., Buraioli, I., Schiavone, D., & Veglio, F.
Venue
Journal of Hypertension
Published
2019-08
Volume
37
Issue
8
Pages
1547-1557
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2922842315
Cited by
236
References
7
FWCI
13.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current assessment of pulse wave velocity: comprehensive review of validation studies. https://app.cochat.ai/papers/10.1097/hjh.0000000000002081
The paper
Milan, A., Zocaro, G., Leone, D., Tosello, F., Buraioli, I., Schiavone, D., & Veglio, F. (2019). Current assessment of pulse wave velocity: comprehensive review of validation studies. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000002081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.