CoChat

Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability

Palatini, Paolo, Asmar, Roland, O’Brien, Eoin, Padwal, Raj, Parati, Gianfranco, Sarkis, Josh, Stergiou, George · 2020 · Journal of Hypertension
Cited by 48

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Blood pressure measurement in obese individuals can be challenging because of the difficulty in properly cuffing large upper arms. Achieving a proper cuff fit can be problematic especially in people with a shorter arm length relative to circumference. This expert statement provides recommendations on blood pressure measurement in large arms for clinical use and research purposes. Tronco-conically shaped cuffs should be used in people with large arms, especially with arm circumferences greater than 42 cm as they better fit on the conical arm shape. Cuffs with frustum of the cone slant angle of 85° should satisfy most conditions. In individuals with short upper-arm that does not allow application of a properly sized cuff, wrist or forearm measurement might be used in clinical practice, but not for validation of automatic devices. Wide-range cuffs coupled to oscillometric devices provided with special software algorithms can also be used as alternatives to standard cuff measurement, provided they are independently validated per AAMI/ISO 81060-2 protocol. For validation studies, the intraarterial measurement is generally considered as the gold standard, yet for possible methodological pitfalls and ethical concerns, it is not recommended as the method of choice. Tronco-conical cuffs with inflatable bladder dimensions of 37–50 × 75–100% arm circumference should be used for reference auscultatory blood pressure measurement wherever the upper arm length allows a proper fit. There is a need for future studies that help identify the optimal shape of cuffs and bladders investigating the influence of sex, age, arm physical properties, and artery characteristics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000002399

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 48

Metadata

Authors
Palatini, P., Asmar, R., O’Brien, E., Padwal, R., Parati, G., Sarkis, J., & Stergiou, G.
Venue
Journal of Hypertension
Published
2020-03-03
Volume
38
Issue
7
Pages
1244-1250
ISSN
  • 0263-6352 (ISSN-L)
  • 1473-5598
OpenAlex
W3009631168
Cited by
48
References
11
FWCI
3.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability. https://app.cochat.ai/papers/10.1097/hjh.0000000000002399
The paper
Palatini, P., Asmar, R., O’Brien, E., Padwal, R., Parati, G., Sarkis, J., & Stergiou, G. (2020). Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000002399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.