Validation of brachial artery pressure reconstruction from finger arterial pressure
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Measurement of finger artery pressure with Finapres offers noninvasive continuous blood pressure, which, however, differs from brachial artery pressure. Generalized waveform filtering and level correction may convert the finger artery pressure waveform to a brachial waveform. An upper-arm cuff return-to-flow measurement may be used to calibrate the blood pressure on an individual basis. We tested these corrective methods as implemented in the Finometer device. METHODS: Intrabrachial artery pressure (BAP) and finger artery pressures were recorded simultaneously in 37 cardiac patients, aged 41-83 years, who underwent a cardiac catheterization procedure. Finger artery pressures were compared after waveform filtering and level correction and after an additional return-to-flow calibration. Measurements were performed in supine and sitting positions. Accuracy and precision were considered clinically acceptable if the mean and standard deviation of the return-to-flow intrabrachial artery pressure (reBAP)-BAP differences were smaller than 5 +/- 8 mmHg (Association for the Advancement of Medical Instrumentation requirements). RESULTS: Finger artery systolic, diastolic and mean pressures for the group differed from that of intrabrachial artery pressure by -10 +/- 13, -12 +/- 8 and -16 +/- 8 mmHg, respectively. After waveform filtering and level correction the filtered level corrected arterial pressure differed by -1 +/- 11, -0 +/- 7 and -2 +/- 7 mmHg. After individual calibration, reBAP differed by 3 +/- 8, 4 +/- 6 and 3 +/- 5 mmHg. Comparable results were found in the sitting position but only when the supine return-to-flow calibration was used. CONCLUSION: Reconstruction of intrabrachial artery pressure from finger artery pressure with waveform filtering and level correction reduces the pressure differences substantially, with diastolic and mean within Association for the Advancement of Medical Instrumentation requirements. After one supine return-to-flow calibration, all pressure differences meet the requirements. Return-to-flow calibration should not be repeated in sitting position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Cited by
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Self-citationThe relationship between cortisol responses to laboratory stress and cortisol profiles in daily life
Kidd, T., Carvalho, L. A., & Steptoe, A. (2014) · Biological Psychology · doi:10.1016/j.biopsycho.2014.02.010 · Cited by 88
Huisman, H. W., Schutte, A. E., Schutte, R., van Rooyen, J. M., Fourie, C. M. T., Mels, C. M. C., Smith, W., Malan, N. T., & Malan, L. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hps007 · Cited by 32
Metadata
- Authors
- Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W.
- Venue
- Journal of Hypertension
- Published
- 2008-07
- Volume
- 26
- Issue
- 7
- Pages
- 1321-1327
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1985227030
- Cited by
- 186
- References
- 4
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.