CoChat

The impact of an electronic monitoring and reminder device on patient compliance with antihypertensive therapy: a randomized controlled trial

Christensen, Arne, Christrup, Lona Louring, Fabricius, Paul Erik, Chrostowska, Marzena, Wronka, Michal, Narkiewicz, Krzysztof, Hansen, Ebba Holme · 2010 · Journal of Hypertension
Cited by 71

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: High blood pressure (BP) significantly increases overall cardiovascular risk, the incidence of ischemic heart disease and stroke. One of the most important causes of insufficient BP control is low treatment compliance. Reminders and electronic compliance monitoring have been shown to be effective in improving patient compliance to some extent, but the combined effect has not been documented. OBJECTIVE: To assess the impact of an electronic reminder and monitoring device on patient compliance and BP control. METHODS: All patients received medical treatment with telmisartan once daily and were randomized to either electronic compliance monitoring with a reminder and monitoring device or standard therapy for 6 months. Both groups were crossed over after 6 months. Intervention effectiveness was assessed using self-reported compliance and BP. RESULTS: Data from 398 patients were analysed. In the first half of the study, patients using the device reported 91% compliance versus 85% in the control group. This difference diminished after crossover (88 versus 86%). BP was not affected. Electronic monitoring data on compliance revealed taking, dosing and timing compliance between 45 and 52% in study group 1, and between 32 and 38% in study group 2. CONCLUSION: The Helping Hand reminder device was most suitable if used for newly diagnosed hypertensive patients, when it improved compliance by 6%. With the present medical treatment, the device does not have any influence on BP control, but with less forgiving medications, the device might make a significant difference. The use of the device can be an easy and effective way to improve compliance in selected patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e328331b718

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 71

Metadata

Authors
Christensen, A., Christrup, L. L., Fabricius, P. E., Chrostowska, M., Wronka, M., Narkiewicz, K., & Hansen, E. H.
Venue
Journal of Hypertension
Published
2010-01
Volume
28
Issue
1
Pages
194-200
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2006962910
Cited by
71
References
5
FWCI
4.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.