Electroretinography in glaucoma diagnosis
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Electrophysiological measures of vision function have for decades generated interest among glaucoma researchers and clinicians alike because of their potential to help elucidate pathophysiological processes and sequence of glaucomatous damage, as well as to offer a potential complementary metric of function that might be more sensitive than standard automated perimetry. The purpose of this article is to review the recent literature to provide an update on the role of the electroretinogram (ERG) in glaucoma diagnosis. RECENT FINDINGS: The pattern reversal ERG (PERG) and the photopic negative response (PhNR) of the cone-driven full-field, focal or multifocal ERG provide objective measures of retinal ganglion cell function and are all sensitive to glaucomatous damage. Recent studies demonstrate that a reduced PERG amplitude is predictive of subsequent visual field conversion (from normal to glaucomatous) and an increased rate of progressive retinal nerve fiber layer thinning in suspect eyes, indicating a potential role for PERG in risk stratification. Converging evidence indicates that some portion of PERG and PhNR abnormality represents a reversible aspect of dysfunction in glaucoma. SUMMARY: PERG and PhNR responses obtained from the central macula are capable of detecting early-stage, reversible glaucomatous dysfunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The field topography of ERG components in man—I. The photopic luminance response
Sutter, E. E., & Tran, D. (1992) · Vision Research · doi:10.1016/0042-6989(92)90235-b · Cited by 946
Oscillatory potentials in the retina: what do they reveal
Wachtmeister, L. (1998) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(98)00006-8 · Cited by 529 · cited 1×
“The OPs are thought to arise within the inner plexiform layer as a consequence of inhibitory feedback loops involving primarily amacrine cells [2].”
BackgroundAssessing retinal function with the multifocal technique
Hood, D. C. (2000) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00013-6 · Cited by 481 · cited 2×
“There are additional types of ERG recordings based on alternative stimulus and recording paradigms rather than full-field flashes such as the well known pattern reversal ERG (PERG) [22] and multifocal ERG (mfERG) [23], which can also be obtained in a routine clinical setting and offer meaningful objective measurements…”
BackgroundThe photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., Harwerth, R. S., & Smith, E. L. (1999) · PubMed · Cited by 417
Sieving, P. A., Murayama, K., & Naarendorp, F. (1994) · Visual Neuroscience · doi:10.1017/s0952523800002431 · Cited by 388
The topography of visual evoked response properties across the visual field
Baseler, H. A., Sutter, E. E., Klein, S. A., & Carney, T. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90114-7 · Cited by 320
The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse
Saszik, S. M., Robson, J. G., & Frishman, L. J. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2002.019703 · Cited by 295
The photopic negative response of the flash electroretinogram in primary open angle glaucoma.
Viswanáthan, S., Frishman, L. J., Robson, J. G., & Walters, J. W. (2001) · PubMed · Cited by 273
Viswanáthan, S., Frishman, L. J., & Robson, J. G. (2000) · PubMed · Cited by 255
Multifocal VEP and ganglion cell damage: applications and limitations for the study of glaucoma
Hood, D. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(02)00061-7 · Cited by 245 · cited 1×
“Thorough reviews of the clinical applications of multifocal ERG and visual evoked response (VER) were published by Hood in 2000 [23] and 2003 [47], respectively.”
Background
Research works printed but not linked: 2
- Heckenlively JR Arden GB Principles and practice of clinical electrophysiology of vision 2006 Cambridge, MA The MIT Press
- Graham SL Fortune B Shaarawy TM Sherwood MB Hitchings RA Crowston JG Electrophysiology in Glaucoma Assessment Glaucoma 2015 2nd. London Elsevier 149 168
Cited by
Items 101–120 of 120
Diagnóstico e tratamento da síndrome do nistagmo infantil: uma revisão de literatura
Júnior, F. E. A. D. S., de Aguiar, R. G. P., Ferreira, J. D. L. M., & Ribeiro, J. C. M. L. (2023) · eOftalmo · doi:10.17545/eoftalmo/2023.0030
“O ERG é uma técnica minimamente invasiva que fornece uma avaliação direta e objetiva da função da retina 16 .”
Full-Field Electroretinogram Responses in Rodent Models of Ganglion Cell Injury
Zhao, D. Y., Lee, P. Y., Wong, V. H. Y., Hoang, A., Tran, K. K. N., van Koeverden, A. K., Afiat, B. C., Nguyen, C. T. O., & Bui, B. V. (2024) · Methods in molecular biology · doi:10.1007/978-1-0716-4140-8_17
Hua, D., Gu, J., Xie, F., Xu, Y., Li, Z., Zheng, H., & Chen, Z. (2024) · European Journal of Ophthalmology · doi:10.1177/11206721241297023
“23,24 In contrast, PhNR measures the functional activity of RGCs.”
Neveu, M. M., Chong, V. N., Empeslidis, T., Scholl, H. P. N., & Robson, A. G. (2025) · Ophthalmic Research · doi:10.1159/000544702
“Comparative studies of the PERG and PhNR have shown similar sensitivity in detecting RGC dysfunction in suspected and early glaucoma, with the PhNR ratio reported to have higher sensitivity in pre-perimetric patients [92, 93].”
Moreno-Carmona, F. M. (2025) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.47.2025.tde-31082025-173244
Long, Z., Zhang, J., Feng, J., & He, T. (2025) · Experimental Eye Research · doi:10.1016/j.exer.2025.110649
Short-term variability of the multifocal ERG in clinical settings
Kahlon, S., Ebedes, D. M., & Tzekov, R. T. (2025) · Documenta Ophthalmologica · doi:10.1007/s10633-025-10069-4
Belforte, N., Agostinone, J., Alarcón-Martínez, L., Villafranca‐Baughman, D., Dotigny, F., Vargas, J. C., & Polo, A. D. (2021) · Figshare · doi:10.6084/m9.figshare.14880590
Tanaka, H., Ishida, K., Ozawa, K., Ishihara, T., Sawada, A., Mochizuki, K., & Yamamoto, T. (2021) · Figshare · doi:10.6084/m9.figshare.16305856
Li, Q., Cheng, Y., Zhang, S., Sun, X., & Wu, J. (2021) · Figshare · doi:10.6084/m9.figshare.17037312
Belforte, N., Agostinone, J., Alarcón-Martínez, L., Villafranca‐Baughman, D., Dotigny, F., Vargas, J. C., & Polo, A. D. (2021) · Figshare · doi:10.6084/m9.figshare.14880593
Tanaka, H., Ishida, K., Ozawa, K., Ishihara, T., Sawada, A., Mochizuki, K., & Yamamoto, T. (2021) · Figshare · doi:10.6084/m9.figshare.16305859
Tanaka, H., Ishida, K., Ozawa, K., Ishihara, T., Sawada, A., Mochizuki, K., & Yamamoto, T. (2021) · Figshare · doi:10.6084/m9.figshare.16305853
Sustained-Release Intraocular Implants in Glaucoma: A New Paradigm for Long-Term Pressure Control
Mendiola, C. C., Loza, J. L. J., Ramírez, D. M. T., Guillin, W. R. C., Jiménez, J. M. C., Gutierrez, C. D. S., Espinal, J. A. V., & Andrade, A. F. R. (2025) · International Science Journal · doi:10.64784/089
Ornelas, R., Arquieta, R. A. F., Vásquez, B. A. R., García, M. A., Prado, L. O. N., Cazares, H. E. A., Guillin, W. R. C., & González, R. A. L. (2025) · International Science Journal · doi:10.64784/083
Role of the Glycogen Synthase Kinase 3 for the Retinal Development and Homeostasis
Braginskaja, E. (2018) · theses.fr (ABES) · doi:10.70675/72532a81z164ez4786z8c84zaf55afbdfa1d
Cheng, T., Yao, T., Zhang, D., Zhang, C., & Suo, L. (2026) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2026.03.018
Jamet, A. J. (2026) · DalSpace (Dalhousie University)
Zeidan, O., & Shaaban, O. A. (2026) · Documenta Ophthalmologica · doi:10.1007/s10633-026-10145-3
ERG diabeetikoilla ja glaukoomapotilailla
Ahonen, T. (2021) · UTUPub (University of Turku)
Metadata
- Authors
- Wilsey, L. J., & Fortune, B.
- Affiliations
- Legacy Health (US)
- Corresponding author
- Fortune, Brad
- Venue
- Current Opinion in Ophthalmology
- Published
- 2016-03
- Volume
- 27
- Issue
- 2
- Pages
- 118-124
- ISSN
- 1040-8738 (ISSN-L)
- PMC
- PMC4698880
- OpenAlex
- W2409899358
- Semantic Scholar
- 225289cb32c0b42327b88e6069cba671a4c9c542
- Cited by
- 113
- References
- 72
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 8 · 2023: 11 · 2022: 19 · 2021: 19 · 2020: 10 · 2019: 13 · 2018: 7 · 2017: 8 · 2016: 4
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Current Opinion in Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Eye Institute (R01EY019327)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Health Sciences › Medicine › Ophthalmology › Drug-Induced Ocular Toxicity
- Keywords
- electroretinogram, glaucoma diagnosis, photopic negative response, retinal ganglion cell function, retinal nerve fiber layer thinning, risk stratification, early glaucomatous damage
- MeSH terms
- Animals, Electroretinography, Glaucoma, Humans, Retina, Retinal Ganglion Cells, Visual Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.