Robotic-assisted surgery in ophthalmology
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. RECENT FINDINGS: Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. SUMMARY: Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The grand challenges of Science Robotics
Yang, G.-Z., Bellingham, J., Dupont, P. E., Fischer, P., Floridi, L., Full, R., Jacobstein, N., Kumar, V., McNutt, M., Merrifield, R., et al. (2018) · Science Robotics · doi:10.1126/scirobotics.aar7650 · Cited by 1,177
Resilient Machines Through Continuous Self-Modeling
Bongard, J., Zykov, V., & Lipson, H. (2006) · Science · doi:10.1126/science.1133687 · Cited by 709
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
New steady-hand Eye Robot with micro-force sensing for vitreoretinal surgery
Uneri, A., Balicki, M. A., Handa, J., Gehlbach, P., Taylor, R. H., & Iordachita, I. (2010) · 2010 3rd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics · doi:10.1109/biorob.2010.5625991 · Cited by 291
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Feasibility study of intraocular robotic surgery with the da Vinci surgical system
BOURLA, D. H., HUBSCHMAN, J. P., CULJAT, M., TSIRBAS, A., GUPTA, A., & SCHWARTZ, S. D. (2008) · Retina · doi:10.1097/iae.0b013e318068de46 · Cited by 106
Da Vinci Xi robot-assisted penetrating keratoplasty
Chammas, J., Sauer, A., Pizzuto, J., Pouthier, F., Gaucher, D., Marescaux, J., Mutter, D., & Bourcier, T. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.3.21 · Cited by 52
Cited by
First-in-Human robot-assisted subretinal drug delivery under local anesthesia
Cehajic-Kapetanovic, J., Xue, K., Edwards, T. L., Meenink, T. C., Beelen, M. J., Naus, G. J., de Smet, M. D., & MacLaren, R. E. (2022) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.11.011 · Cited by 78
Self-citationSurgical technique for subretinal gene therapy in humans with inherited retinal degeneration
Davis, J. L., Gregori, N. Z., MacLaren, R. E., & Lam, B. L. (2019) · Retina · doi:10.1097/iae.0000000000002609 · Cited by 72
Subretinal therapy: technological solutions to surgical and immunological challenges
Ladha, R., Caspers, L. E., Willermain, F., & de Smet, M. D. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.846782 · Cited by 54
“Robotic systems specifically designed for intraocular surgery fall in three main categories: smart surgical tools, comanipulation and telemanipulation which are described more extensively in a review from 2018 (71).”
BackgroundLadha, R., Meenink, T., Smit, J., & de Smet, M. D. (2023) · Gene Therapy · doi:10.1038/s41434-021-00262-w · Cited by 42
Human/robotic interaction: vision limits performance in simulated vitreoretinal surgery
de Smet, M. D., de Jonge, N., Iannetta, D., Faridpooya, K., van Oosterhout, E., Naus, G., Meenink, T. C. M., Mura, M., & Beelen, M. J. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14003 · Cited by 13
Self-citation
Metadata
- Authors
- de Smet, M. D., Naus, G. J. L., Faridpooya, K., & Mura, M.
- Venue
- Current Opinion in Ophthalmology
- Published
- 2018-05
- Volume
- 29
- Issue
- 3
- Pages
- 248-253
- ISSN
- 1040-8738 (ISSN-L)
- OpenAlex
- W2789716155
- Cited by
- 83
- References
- 7
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robotic-assisted surgery in ophthalmology. https://app.cochat.ai/papers/10.1097/icu.0000000000000476
- The paper
- de Smet, M. D., Naus, G. J. L., Faridpooya, K., & Mura, M. (2018). Robotic-assisted surgery in ophthalmology. Current Opinion in Ophthalmology. https://doi.org/10.1097/icu.0000000000000476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.