Bioengineering an electro-mechanically functional miniature ventricular heart chamber from human pluripotent stem cells

Open access
Li, Ronald A., Keung, Wendy, Cashman, Timothy J., Backeris, Peter C., Johnson, Bryce V., Bardot, Evan S., Wong, Andy O.T., Chan, Patrick K.W. +2 more·2018·Biomaterials

Abstract

Tissue engineers and stem cell biologists have made exciting progress toward creating simplified models of human heart muscles or aligned monolayers to help bridge a longstanding gap between experimental animals and clinical trials. However, no existing human in vitro systems provide the direct measures of cardiac performance as a pump. Here, we developed a next-generation in vitro biomimetic model of pumping human heart chamber, and demonstrated its capability for pharmaceutical testing. From human pluripotent stem cell (hPSC)-derived ventricular cardiomyocytes (hvCM) embedded in collagen-based extracellular matrix hydrogel, we engineered a three-dimensional (3D) electro-mechanically coupled, fluid-ejecting miniature human ventricle-like cardiac organoid chamber (hvCOC). Structural characterization showed organized sarcomeres with myofibrillar microstructures. Transcript and RNA-seq analyses revealed upregulation of key Ca 2+-handling, ion channel, and cardiac-specific proteins in hvCOC compared to lower-order 2D and 3D cultures of the same constituent cells. Clinically-important, physiologically complex contractile parameters such as ejection fraction, developed pressure, and stroke work, as well as electrophysiological properties including action potential and conduction velocity were measured: hvCOC displayed key molecular and physiological characteristics of the native ventricle, and showed expected mechanical and electrophysiological responses to a range of pharmacological interventions (including positive and negative inotropes). We conclude that such "human-heart-in-a-jar" technology could facilitate the drug discovery process by providing human-specific preclinical data during early stage drug development.

Integrity signals

Registry

Crossref · 10.1016/j.biomaterials.2018.02.024

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

52 of 74 cited sources checked · 30 supported · 0 flagged · accuracy not yet measured

  • Premisecitation

    Engineered cardiac thin films, micro-tissues, and strips permit measurement of twitch force.

    “engineered cardiac thin films, micro-tissues and strips allow the assessment of twitch force [9,12–19]”
    Quote in the paperSubstantial claim7 of 9 sources checked
    • cites [9] Tulloch, 2011, Growth of engineered human myocardium with mechanical loading and vascular coculture, Circ. Res. source
      Experimental — accuracy not yet measured
    • cites [12] Hansen, 2010, Development of a drug screening platform based on engineered heart tissue, Circ. Res. source
    • cites [13] Thavandiran, 2013, Design and formulation of functional pluripotent stem cell-derived cardiac microtissues, Proc. Natl. Acad. Sci. U. S. A. source
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source
      Experimental — accuracy not yet measured
    • cites [15] Huang, 2007, Contractile three-dimensional bioengineered heart muscle for myocardial regeneration, J. Biomed. Mater. Res. source
      Experimental — accuracy not yet measured
    • cites [16] Schaaf, 2011, Human engineered heart tissue as a versatile tool in basic research and preclinical toxicology, PLoS One source
      Experimental — accuracy not yet measured
    • cites [17] Wang, 2014, Modeling the mitochondrial cardiomyopathy of Barth syndrome with induced pluripotent stem cell and heart-on-chip technologies, Nat. Med. source

      The Abstract (page unavailable) describes engineered muscular thin films and calculates twitch stress from their contraction, supporting the thin-film part of the claim. The passages do not establish that this paper used micro-tissues or strips to assess twitch force. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [18] Chen, 2015, Phospholamban as a crucial determinant of the inotropic response of human pluripotent stem cell-derived ventricular cardiomyocytes and engineered 3-dimensional tissue constructs, Circ. Arrhythm. Electrophysiol. source

      The Methods section on microtissue force quantification describes measuring forces from engineered cardiac microtissues, and the Results report their measured twitch tension. The Results also describe twitch-force measurements in engineered cardiac tissue strips. Our copy does not address cardiac thin films, so it supports only two of the three formats listed. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [19] Kensah, 2013, Murine and human pluripotent stem cell-derived cardiac bodies form contractile myocardial tissue in vitro, Eur. Heart J. source
      Experimental — accuracy not yet measured
  • Premisecitation

    Those constructs do not permit pressure- and volume-based measures that directly reflect pump performance.

    “but not pressure- and volume-based metrics directly representing pump performance of the heart”
    Quote in the paperSubstantial claim7 of 9 sources checked
    • cites [9] Tulloch, 2011, Growth of engineered human myocardium with mechanical loading and vascular coculture, Circ. Res. source
      Experimental — accuracy not yet measured
    • cites [12] Hansen, 2010, Development of a drug screening platform based on engineered heart tissue, Circ. Res. source
    • cites [13] Thavandiran, 2013, Design and formulation of functional pluripotent stem cell-derived cardiac microtissues, Proc. Natl. Acad. Sci. U. S. A. source
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source

      Materials and Methods and Results describe force and twitch-stress measurements on engineered cardiac tissues, rather than pressure–volume measures of heart-pump performance. The paper does not explicitly establish that these constructs cannot permit pressure- or volume-based measurements, so the categorical limitation goes beyond what our copy states. (LLM, conf=0.78)

      Experimental — accuracy not yet measured
    • cites [15] Huang, 2007, Contractile three-dimensional bioengineered heart muscle for myocardial regeneration, J. Biomed. Mater. Res. source
      Experimental — accuracy not yet measured
    • cites [16] Schaaf, 2011, Human engineered heart tissue as a versatile tool in basic research and preclinical toxicology, PLoS One source

      The Discussion (page unavailable) says the hEHT assay measures contraction frequency, force, timing and velocity, rather than pressure or volume. It does not establish the stronger claim that the constructs cannot permit pressure- or volume-based measures of pump performance. (LLM, conf=0.82)

      Experimental — accuracy not yet measured
    • cites [17] Wang, 2014, Modeling the mitochondrial cardiomyopathy of Barth syndrome with induced pluripotent stem cell and heart-on-chip technologies, Nat. Med. source

      The Abstract and the MTF stress-quantitation passage (no page given) describe laminar thin-film constructs whose curvature is used to calculate contractile stress, rather than pressure or volume. The paper does not explicitly state that these constructs cannot provide pressure- and volume-based measures of cardiac pump performance. (LLM, conf=0.78)

      Experimental — accuracy not yet measured
    • cites [18] Chen, 2015, Phospholamban as a crucial determinant of the inotropic response of human pluripotent stem cell-derived ventricular cardiomyocytes and engineered 3-dimensional tissue constructs, Circ. Arrhythm. Electrophysiol. source
      Experimental — accuracy not yet measured
    • cites [19] Kensah, 2013, Murine and human pluripotent stem cell-derived cardiac bodies form contractile myocardial tissue in vitro, Eur. Heart J. source
      Experimental — accuracy not yet measured
  • Findingcitation

    Upon 1-Hz electrical stimulation, AP initiation was followed by Ca2+ transient initiation after a systematic and reproducible delay.

    “Furthermore, Fig. 5c shows the immediate initiation of an AP (black tracing) upon 1-Hz electrical stimulation (black arrows at 0 and 1000 ms) followed by Ca2+ transient initiation (blue tracing) after a systematic and reproducible delay, as anticipated from Ca2+-induced-Ca2+-release upon Ca2+ influx via L-type Ca2+ channels [28] that subsequently lead to cardiac contractions.”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [28] Li, 2014, Mechanistic basis of excitation-contraction coupling in human pluripotent stem cell-derived ventricular cardiomyocytes revealed by Ca2+ spark characteristics: direct evidence of functional Ca2+-induced Ca2+ release, Heart Rhythm source
  • Findingown data

    As pacing frequency increased, APD50 and conduction velocity decreased in hvCOC, indicating rate-adaptation.

    “As the pacing frequency was increased (Fig. 5c) (i.e., shorter basic cycle length, BCL), the AP duration at 50% amplitude (APD50) (Fig. 5d) and the conduction velocity (CV) (Fig. 5e) decreased, indicating the ability of hvCOC to rate-adapt, another key physiological feature of native cardiac cells and tissues [40,41].”
    Quote in the paperSubstantial claim1 of 2 sources checked
    • cites [40] Bass, 1975, Some electrical and mechanical effects of strontium on toad ventricular muscle: comparison to calcium, J. Physiol. source
    • cites [41] Boyett, 1980, Analysis of the effects of changes in rate and rhythm upon electrical activity in the heart, Prog. Biophys. Mol. Biol. source
  • Findingown data

    Transcript analysis of hvCOC and other engineered constructs showed changes consistent with prior maturation studies.

    “Transcript analysis of 2D-cultured clusters [24] and alternative engineered constructs, including human ventricular cardiac micro-tissues (hvCMT; ~1000 cells) [18], tissue strips (hvCTS; ~106 cells) [14] and hvCOC made of identical constituent hPSC-vCMs, revealed changes consistent with our previous maturation studies [18,24–28].”
    Quote in the paperSubstantial claim4 of 6 sources checked
    • cites [18] Chen, 2015, Phospholamban as a crucial determinant of the inotropic response of human pluripotent stem cell-derived ventricular cardiomyocytes and engineered 3-dimensional tissue constructs, Circ. Arrhythm. Electrophysiol. source

      The Results identify hvCMTs as engineered microtissues of approximately 1,000 ventricular cardiomyocytes, so the source supports that part of the citing sentence. The Transcriptomic Analysis methods describe RNA analysis of hES2-vCMs, not of hvCMTs; the Discussion says their global transcriptome was unchanged after PLB overexpression. This source therefore does not establish transcript changes in the engineered constructs consistent with maturation studies. No page numbers are available in our copy. (LLM, conf=0.86)

      Experimental — accuracy not yet measured
    • cites [24] Li, 2013, Calcium signalling of human pluripotent stem cell-derived cardiomyocytes, J. Physiol. source
    • cites [25] Liu, 2007, Functional sarcoplasmic reticulum for calcium handling of human embryonic stem cell-derived cardiomyocytes: insights for driven maturation, Stem Cell. source
    • cites [26] Liu, 2009, Facilitated maturation of Ca2+ handling properties of human embryonic stem cell-derived cardiomyocytes by calsequestrin expression, Am. J. Physiol. Cell Physiol. source
    • cites [27] Lieu, 2009, Absence of transverse tubules contributes to non-uniform Ca(2+) wavefronts in mouse and human embryonic stem cell-derived cardiomyocytes, Stem Cell. Dev. source
    • cites [28] Li, 2014, Mechanistic basis of excitation-contraction coupling in human pluripotent stem cell-derived ventricular cardiomyocytes revealed by Ca2+ spark characteristics: direct evidence of functional Ca2+-induced Ca2+ release, Heart Rhythm source

      The Conclusions (page unavailable) describe developmentally immature hESC-derived ventricular cardiomyocytes and suggest that the findings may inform maturation strategies. But this paper studies calcium sparks and excitation–contraction coupling; it does not report transcript changes in hvCOC or the other engineered constructs, so it cannot establish the claimed consistency at the transcript level. (LLM, conf=0.75)

      Experimental — accuracy not yet measured
  • Classified as probably not a substantial claim. 15
  • May combine two claims. 17
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    Prior studies have arranged hPSC-derived ventricular cardiomyocytes as monolayers and patches for electrophysiology and for surgical implantation.

    “Although hPSC-vCMs have been organized as monolayers and patches for electrophysiological assessment [6–8] and even surgical engraftment [9–11]”
    Quote in the paperSubstantial claim5 of 6 sources checked
    • cites [6] Chen, 2011, Shrink-film configurable multiscale wrinkles for functional alignment of human embryonic stem cells and their cardiac derivatives, Adv. Mater. source

      The paper’s Experimental Section reports optical mapping of action-potential propagation in aligned hESC-derived cardiomyocyte monolayers, supporting the electrophysiology portion. It does not identify those cells specifically as ventricular cardiomyocytes or report patches or surgical implantation. The citing sentence assigns surgical engraftment to a separate citation group [9–11]. (LLM, conf=0.87)

      Experimental — accuracy not yet measured
    • cites [7] Wang, 2013, Effect of engineered anisotropy on the susceptibility of human pluripotent stem cell-derived ventricular cardiomyocytes to arrhythmias, Biomaterials source
    • cites [8] Zhang, 2013, Tissue-engineered cardiac patch for advanced functional maturation of human ESC-derived cardiomyocytes, Biomaterials source
    • cites [9] Tulloch, 2011, Growth of engineered human myocardium with mechanical loading and vascular coculture, Circ. Res. source
    • cites [10] Caspi, 2007, Tissue engineering of vascularized cardiac muscle from human embryonic stem cells, Circ. Res. source

      The Generation of the Engineered Human Cardiac Tissue section describes hESC-derived cardiomyocytes seeded on three-dimensional scaffolds, and Impulse Propagation reports electrical activity in those constructs. The paper does not report surgical implantation or engraftment; it presents tissue replacement as a potential application. It also does not describe its constructs as monolayers. (LLM, conf=0.86)

      Experimental — accuracy not yet measured
    • cites [11] Wendel, 2015, Functional effects of a tissue-engineered cardiac patch from human induced pluripotent stem cell-derived cardiomyocytes in a rat infarct model, Stem Cells Trans. Med. source
  • Classified as probably not a substantial claim.

    Premisecitation

    Human pluripotent stem cells can be differentiated into ventricular cardiomyocytes that prior work has characterized thoroughly at the single-cell level.

    “Human pluripotent stem cells (hPSC) can be specified into ventricular cardiomyocytes (vCM) that have been robustly characterized at the single-cell level [2–5].”
    Quote in the paperSubstantial claim2 of 4 sources checked
    • cites [2] Mummery, 2003, Differentiation of human embryonic stem cells to cardiomyocytes: role of coculture with visceral endoderm-like cells, Circulation source
    • cites [3] He, 2003, Human embryonic stem cells develop into multiple types of cardiac myocytes: action potential characterization, Circ. Res. source
    • cites [4] Xue, 2005, Functional integration of electrically active cardiac derivatives from genetically engineered human embryonic stem cells with quiescent recipient ventricular cardiomyocytes: insights into the development of cell-based pacemakers, Circulation source
    • cites [5] Lieu, 2013, Mechanism-based facilitated maturation of human pluripotent stem cell-derived cardiomyocytes, Circ. Arrhyth. Electrophysiol. source
  • May combine two claims.

    Findingown data

    The sarcomeric organization of hvCOC resembled other human engineered cardiac tissue constructs and differed from random clusters.

    “with sarcomeric arrangements similar to other human engineered cardiac tissue constructs [14,21–23] but distinct from random clusters.”
    Quote in the paperNot a substantial claim4 of 4 sources checked
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source
    • cites [21] Boudou, 2012, A microfabricated platform to measure and manipulate the mechanics of engineered cardiac microtissues, Tissue Eng. Part A source

      The Results (page not provided) describe engineered cardiac microtissues developing aligned, parallel cross-striations after an initially almost random cellular arrangement. That supports the contrast with random clusters, but this paper used neonatal rat heart cells and does not establish a comparison with human engineered cardiac tissue constructs. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [22] Kerscher, 2016, Direct hydrogel encapsulation of pluripotent stem cells enables ontomimetic differentiation and growth of engineered human heart tissues, Biomaterials source
    • cites [23] Nunes, 2013, Biowire: a platform for maturation of human pluripotent stem cell-derived cardiomyocytes, Nat. Methods source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    The weak β-adrenergic response is thought to result from immature adrenergic and Ca2+ signaling pathways, such as lowered phospholamban expression.

    “The weak response is thought to be due to immature adrenergic and Ca2+ signaling pathways such as lowered phospholamban expression compared to their adult counterparts [14].”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source

      The Results report a weak sustained inotropic response to β-adrenergic stimulation and suggest immature sarcoplasmic-reticulum function or reduced β-receptor sensitivity as possible explanations. The Discussion also raises differences in β-signaling maturity. Our copy does not support the specific example of lowered phospholamban expression compared with adult tissue. (LLM, conf=0.87)

      Experimental — accuracy not yet measured
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    We previously reported a linear relationship between developed stress and axial stretch in hvCTS.

    “Similarly, we have reported a linear relationship between the developed stress and axial stretch in hvCTS [14].”
    Quote in the paperNot a substantial claim1 of 1 sources checked
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source

      The Results (page not provided) report that developed stress increased with axial stretch in hECTs, supporting the relationship's direction. They do not describe it as linear and say stress reached a plateau at Lmax; the Methods specify linear regression for the force-frequency relationship, not the stretch relationship. (LLM, conf=0.87)

      Experimental — accuracy not yet measured
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Engineered tissues with contractile forces and conduction properties approaching native myocardium have been reported by several groups.

    “A number of groups have reported engineered tissues with contractile forces and conduction properties approaching physiologic levels observed in native myocardium [8,13,31,32].”
    Quote in the paperNot a substantial claim3 of 4 sources checked
    • cites [8] Zhang, 2013, Tissue-engineered cardiac patch for advanced functional maturation of human ESC-derived cardiomyocytes, Biomaterials source
    • cites [13] Thavandiran, 2013, Design and formulation of functional pluripotent stem cell-derived cardiac microtissues, Proc. Natl. Acad. Sci. U. S. A. source
    • cites [31] Guyette, 2016, Bioengineering human myocardium on native extracellular matrix, Circ. Res. source

      The Results (Recellularization of myocardial slices and fibers; page unavailable) report contractile force and a conduction velocity of 32 ± 56 cm/s in engineered tissue. But the reported slice force reached 33.8% of native murine embryonic heart tissue, slice strain was below normal adult myocardium, and the copy gives no native-myocardium benchmark for conduction velocity. It therefore supports the presence of mechanical and electrical function, but not the full claim that both properties approached physiologic levels. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [32] Herron, 2016, Extracellular matrix-mediated maturation of human pluripotent stem cell-derived cardiac monolayer structure and electrophysiological function, Circ Arrhythm. Electrophysiol source

      The Results (ECM Effects on iCell hiPSC-CM Monolayer Impulse Propagation; page unavailable) report engineered cardiac monolayers with conduction velocities as high as 55 cm/s, approaching the adult-heart range described in the Introduction. The Discussion says their myofilament changes may promote greater tension development, but the paper does not report contractile-force measurements approaching native myocardium. This citation therefore supports the conduction part, not the force part of the sentence. (LLM, conf=0.88)

      Experimental — accuracy not yet measured
  • May combine two claims.

    Findingown data

    hvCOC showed augmented sensitivity to adrenergic stimulation and both chronotropic and inotropic effects compared with hvCTS and hvCMT systems constructed with the same hPSC-vCMs.

    “Functionally, we observed an augmented sensitivity of the hvCOC to adrenergic stimulation and the presence of both chronotropic and inotropic effects when compared with the hvCTS and hvCMT systems constructed with the same hPSC-vCMs [14,18].”
    Quote in the paperSubstantial claim2 of 2 sources checked
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source

      The Results (page not provided) report a strong chronotropic response but a negligible sustained inotropic response to isoproterenol in the paper’s hECTs. This supports part of the comparison, but the paper does not assess hvCOC or establish that its tissues were made from the same cardiomyocytes as the citing authors’ systems, so it cannot substantiate the claimed relative sensitivity. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [18] Chen, 2015, Phospholamban as a crucial determinant of the inotropic response of human pluripotent stem cell-derived ventricular cardiomyocytes and engineered 3-dimensional tissue constructs, Circ. Arrhythm. Electrophysiol. source

      The Results section reports that β-adrenergic stimulation increased beating frequency but not twitch tension in hvCMTs, and says cardiac tissue strips likewise showed a positive chronotropic but negligible inotropic response. The paper therefore supports the comparator response described in the citing sentence, but it does not assess hvCOC or establish its greater sensitivity; the citing authors present that as their own observation. No page number is available in our copy. (LLM, conf=0.84)

      Experimental — accuracy not yet measured
  • May combine two claims.

    Findingown data

    Verapamil decreased stroke volume, cardiac output, and developed pressure, with P-V loops showing decreases in end-systolic pressure and stroke work.

    “Consistent with a negative inotropic effect resulting from reduced Ca2+ entry that we reported in our previous studies with hvCTS and hvCMT [14,18], the stroke volume, cardiac output, and developed pressure decreased (shown in Fig. 4a) with the P-V loops likewise exhibiting decreases in end-systolic pressure and stroke work (Fig. 4b).”
    Quote in the paperSubstantial claim2 of 2 sources checked
    • cites [14] Turnbull, 2014, Advancing functional engineered cardiac tissues toward a preclinical model of human myocardium, Faseb. J. source
    • cites [18] Chen, 2015, Phospholamban as a crucial determinant of the inotropic response of human pluripotent stem cell-derived ventricular cardiomyocytes and engineered 3-dimensional tissue constructs, Circ. Arrhythm. Electrophysiol. source

      The Results section reports reduced twitch tension in hvCMTs after PLB transduction, supporting a negative inotropic effect. But the Results on Ca²⁺ transients say PLB transduction did not alter L-type Ca²⁺ current; the paper does not report verapamil treatment or the cited pressure–volume measures. In the citing sentence, those measures are presented as the citing authors’ own Fig. 4 results, while the citation is attached to the prior-study comparison. (LLM, conf=0.82)

      Experimental — accuracy not yet measured
  • May combine two claims.

    Findingown data

    Electron microscopy showed Z-lines, other sub-sarcomeric structures, and myofibrils interspersed with mitochondria in hvCOC.

    “Electron microscopy further revealed clearly visible Z-lines and other sub-sarcomeric structures and myofibrils intercalated with mitochondria (Fig. 1i)”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    After 10 days of incubation, hvCOCs had a hollow chamber shape and a wall thickness of about 100 μm.

    “Following incubation for 10 days, the resulting hvCOCs exhibited a hollow chamber geometry (Fig. 1f) with cells distributed across a wall thickness of approximately 100 μm (Fig. 1g).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingcitation

    Verapamil initially increased and then at higher concentrations decreased APD50, with shortened plateau phase and reduced amplitudes, secondarily increasing firing frequency.

    “As described in guinea pig ventricular myocytes [42], the L-type Ca2+ channel blocker verapamil initially increased and then at higher concentrations decreased the APD50, with a shortened plateau phase and reduced amplitudes, thereby secondarily increasing the firing frequency (Fig. 6a, d).”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [42] Zhang, 1997, Multiple modulations of action potential duration by different calcium channel blocking agents in Guinea pig ventricular myocytes, J. Cardiovasc. Pharmacol. source
  • Classified as probably not a substantial claim.

    Findingown data

    Over 10 days, the tissue compacted around the balloon core to form a human engineered cardiac organoid.

    “during which time the tissue compacted around the balloon core to form a human engineered cardiac organoid.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    In hvCOC, cyclical pressure and volume changes were out-of-phase, and reconstructed PV loops progressed counter-clockwise.

    “Mechanically, cyclical changes in pressure (P) and volume (V) were out-of-phase such that an increase in chamber pressure was accompanied by a decrease in volume, and vice versa; as a result, the reconstructed PV loops exhibited a counter-clockwise progression throughout the beating cycle (see Fig. 3b–c for a representative experiment).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    At selected loading pressures, reconstructed P-V loops progressed counter-clockwise, indicating positive stroke work that increased with mean pressure.

    “At selected loading pressures the reconstructed P-V loops progressed counter-clockwise (Fig. 3h), indicating positive stroke work that increased with mean pressure.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    EC50 values for cardiac output were 61.7 ± 6.6 nM for verapamil, 15.4 ± 9.4 nM for nifedipine, and 354.5 ± 42.7 nM for disopyramide.

    “The EC50 values for their cardiac outputs were 61.7 ± 6.6 nM, 15.4 ± 9.4 nM and 354.5 ± 42.7 nM, respectively, which are in the range of those previously reported with Langendorff heart experiments [38,39].”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [38] Hugtenburg, 1989, The differential effect of calcium antagonists on the positive inotropic effects induced by calcium and monensin in cardiac preparations of rats and Guinea-pigs, Naunyn-Schmiedeberg’s Arch. Pharmacol. source
    • cites [39] Matsumoto, 1993, Relationship between negative inotropic and chronotropic effects of tocainide and five class I antiarrhythmic drugs in the coronary perfused Guinea-pig heart, Gen. Pharmacol. source
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Findingown data

    The tissue mixture contained about 90% cTNT+MLC2v+ cells and 1 million cells/mL human dermal fibroblasts.

    “10 million cells/mL tissue mixture of which about 90% were cTNT+MLC2v+ (Supplemental Fig. 1), with an additional 1 million cells/mL human dermal fibroblasts to aid in tissue compaction”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Connexin-43 was elevated in hvCOC compared to other engineered constructs, but not different from 2D culture.

    “Connexin-43 was elevated in hvCOC compared to the other engineered constructs, though not different from 2D culture.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    This observation was consistent with upregulation of PLB as demonstrated by qPCR and ranking of cGMP-PKG and calcium signaling pathways among top 10 upregulated pathways.

    “This observation was consistent with an upregulation of PLB as demonstrated by our qPCR and the ranking of the pathways ‘cGMP-PKG signaling pathway’ and ‘calcium signaling pathway’ among the top 10 pathways with the highest number of upregulated genes in KEGG pathway analysis of the RNA-sequencing data (Supplemental Fig. 4a).”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingreasoning

    The bioreactor design enables a single researcher to assemble 8-10 hvCOCs per week with a success rate of about 70-80%.

    “in particular, our bioreactor design enables a single researcher to assemble 8–10 hvCOCs per week with a success rate of about 70–80%.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Isoproterenol dose-dependently increased spontaneous AP firing with concomitant increases in CV and decreases in APD50.

    “As for positive inotropic interventions, the addition of isoproterenol dose-dependently increased spontaneous AP firing with concomitant increases in CV and decreases in APD50 (Fig. 6a and b), consistent with an intact chronotropic response and mirroring the increased spontaneous beating rate already presented in Fig. 4a.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Findingown data

    Approximately 50% increase in pressure and ejection fraction and 100% increase in stroke work could be achieved by prolonging culture time to Day 20.

    “Indeed, approximately 50% increase in pressure and ejection fraction and 100% increase in stroke work could be achieved by prolonging the culture time to Day 20 (data not shown).”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationown data

    The authors created a 3D miniature ventricle-like cardiac organoid chamber (hvCOC) that is electro-mechanically coupled and ejects fluid, and that reproduces key molecular, physiological, and pharmacological features of the native ventricle.

    “we engineered a three-dimensional (3D) electro-mechanically coupled, fluid-ejecting miniature human ventricle-like cardiac organoid chamber (hvCOC).”
    • Also stated in: § Introduction · plain
      “herein we describe the engineering of a 3D electro-mechanically coupled, fluid-ejecting human ventricle-like cardiac organoid chamber (hvCOC) that recapitulates key molecular, physiological and pharmacological features of the native ventricle.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Existing human in vitro systems do not directly measure how the heart performs as a pump.
    • Rests on an assumption: Monolayer and patch constructs are not intended for contractile characterization.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    During optical mapping, the silicone balloon inside the hvCOC stayed inflated to prevent spontaneous movement and motion artifacts.

    “Throughout the optical mapping experiment, the silicone balloon inside the hvCOC remained inflated to impede spontaneous movement of the hvCOC to avoid motion artifacts.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    The study included only hPSC-CM batches in which more than 70% of cells expressed cardiac troponin-T.

    “Only batches of hPSC-CMs with >70% of cells positively expressing cardiac troponin-T (cTnT) were included in the study.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    At least three hvCOC were analyzed for each pharmacological intervention.

    “data from at least n = 3 hvCOC were collected for each intervention.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisecitation

    The Frank-Starling mechanism is a hallmark of cardiac physiology: ventricular stroke volume increases with filling blood volume.

    “A hallmark characteristic of cardiac physiology is the Frank-Starling mechanism by which the ventricular stroke volume increases as the volume of filling blood increases. In native cardiac muscle experiments, this translates into the generation of stronger twitch forces with increasing preload or stretch [35].”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [35] Allen, 1985, The cellular basis of the length-tension relation in cardiac muscle, J. Mol. Cell. Cardiol. source
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Preparations with spontaneous reentrant arrhythmia at baseline, about 20% of the total, were excluded from further analysis.

    “preparations demonstrating spontaneous reentrant arrhythmia in baseline condition (~20% of total preparations) were excluded from further analysis.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    The hvCOC system is complementary to other existing tools for drug discovery and disease modeling, and allows organ-level measurements of cardiac pump performance not previously possible with human in vitro systems.

    “The hvCOC system is complementary to other existing tools for drug discovery and disease modeling, and allows organ-level measurements of cardiac pump performance that have not been previously possible with human in vitro systems.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Interpretationreasoning

    In combination with somatic reprogramming of induced hPSC and control of cellular composition and external milieu, the 'human-heart-in-a-jar' system offers an advanced biomaterial platform for next-generation drug discovery, cardiotoxicity screening, disease modeling and other applications.

    “In combination with somatic reprogramming of induced hPSC and the control of cellular composition as well as the external milieu, such a “human-heart-in-a-jar” system offers an advanced biomaterial platform representing the upper end of a tiered screening approach for next-generation drug discovery, cardiotoxicity screening, disease modeling and other ethnicity-, sex- and patient-specific”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    The ability to measure both mechanical and electrical properties in a simplified yet biomimetic model of a human ventricle offers new avenues to bridge the gap between traditional cell culture systems, in vivo animal models and clinical trials.

    “Combined, the ability to measure both mechanical and electrical properties in a simplified yet biomimetic model of a human ventricle offers new avenues to help bridge the longstanding gap between traditional cell culture systems, in vivo animal models and clinical trials.”
    Quote in the paperNot a substantial claim
30 of 30
  • The paper relies on this without support.

    Existing human in vitro systems do not directly measure how the heart performs as a pump.

    “However, no existing human in vitro systems provide the direct measures of cardiac performance as a pump.”
  • The paper relies on this without support.

    Monolayer and patch constructs are not intended for contractile characterization.

    “such constructs are not designed for contractile characterization”
  • The authors state this as an assumption.

    Chamber volume can be estimated by treating the chamber as a sphere with the same cross-sectional area.

    “Chamber volume was estimated by assuming an equivalent sphere with the same cross-sectional area.”
3 of 3

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Engineered cardiac organoid chambers made of cardiomyocytes in isotropic hydrogels showed promise for intra-ventricular pressure measurements, but lack of scaffold hampers formation of organized tissues recapitulating native myocardial laminar architecture.

    “Engineered cardiac organoid chambers comprised of cardiomyocytes embedded in isotropic hydrogels showed significant promise for obtaining intra-ventricular pressure measurements26–29 but the lack of a scaffold to guide cell assembly hampers the formation of organized tissues that recapitulate the laminar architecture30,31 of the native myocardium.”

    From A tissue-engineered scale model of the heart ventricle (2018) · cites this paper as [29]

    Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • Methods such as microcontact printing, photolithography, directional freeze drying, fiber spinning, and microphysiological chip fabrication are limited in producing tissues on complex geometries that fully replicate cardiac function.

    “These methods are however limited in their ability to produce tissues on complex geometries that fully replicate cardiac function.”

    From Fibre-infused gel scaffolds guide cardiomyocyte alignment in 3D-printed ventricles (2023) · cites this paper as [10]

    The Introduction (page not provided) says earlier cardiac monolayers, patches, thin films, micro-tissues and strips could not provide direct pressure- and volume-based measures of heart-pump performance. It does not assess the five named fabrication methods or establish that they are limited in producing tissues on complex geometries. The paper discusses recapitulating key cardiac features, not fully replicating cardiac function. (LLM, conf=0.85)

    Experimental — accuracy not yet measured
  • These volume-handling models are limited to a single ventricle and lack perfusion capacity.

    “However, these tissues are limited to a single ventricle model and thus lack the capacity for perfusion.”

    From In situ expansion, differentiation, and electromechanical coupling of human cardiac muscle in a 3D bioprinted, chambered organoid (2020) · cites this paper as [6]

    The Introduction and Discussion describe a simplified, single ventricle-like chamber, supporting the single-ventricle part of the claim. The Discussion contrasts the model with native heart tissue that has integrated vasculature, but the paper does not establish that being a single-ventricle model causes a lack of perfusion capacity. The Results also report that the chamber pumps fluid, so lack of perfusion should not be read as lack of fluid movement. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • The thinnest hChaMP walls match prior literature values, while the thickest walls greatly exceed existing tissue models.

    “Wall thicknesses on the low end of this spectrum match what has been previously demonstrated in the literature, and the high end of the spectrum far exceeds existing tissue models6–8.”

    From In situ expansion, differentiation, and electromechanical coupling of human cardiac muscle in a 3D bioprinted, chambered organoid (2020) · cites this paper as [6]

    The Results section (Bioengineering hvCOC; page unavailable) reports a wall thickness of approximately 100 μm. It does not compare that thickness with prior wall-thickness values or establish that thicker hChaMP walls exceed existing tissue models. The cited paper also studies hvCOCs, not the citing document’s hChaMPs. (LLM, conf=0.78)

    Experimental — accuracy not yet measured
  • The hChaMP maintained its functions for at least six weeks, whereas most comparable models have been characterized only up to two weeks after fabrication.

    “Notably, we show that the hChaMP can maintain these functions for at least 6 weeks, while most similar models have been characterized only up to 2 weeks after fabrication6–8, 18.”

    From In situ expansion, differentiation, and electromechanical coupling of human cardiac muscle in a 3D bioprinted, chambered organoid (2020) · cites this paper as [6]

    The Materials and methods describe functional testing of this paper’s ventricular chamber after 10–12 days in culture, which supports it as an example of a model characterized around two weeks. The Discussion also describes improved function with culture extended to day 20. Neither passage establishes that most comparable models were characterized only up to two weeks; the six-week result is the citing authors’ own finding, not a claim attributed to this source. (LLM, conf=0.75)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

  • Stimulus strength does not match the stated voltage and electrode spacing

    Major

    The field strength and hardware values given here are not mutually consistent. A 10 V stimulus across 19 cm corresponds to about 52.6 mV/mm, not 63 mV/mm.

    Reported 63 · recomputed 0.526316

1 of 1

Cites

Flagged first, then by citations

2 of the 51 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Li, R. A., Keung, W., Cashman, T. J., Backeris, P. C., Johnson, B. V., Bardot, E. S., Wong, A. O. T., Chan, P. K. W., Chan, C. W. Y., & Costa, K. D.
Affiliations
  • Karolinska Institutet (SE)
  • Icahn School of Medicine at Mount Sinai (US)
  • University of Hong Kong (HK)
Corresponding author
  • Li, Ronald A.
  • Costa, Kevin D.
Venue
Biomaterials
Publisher
Elsevier BV
Published
2018-05
Volume
163
Pages
116-127
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2791886935
Cited by
175
References
51
Citations by year
2026: 12 · 2025: 13 · 2024: 14 · 2023: 23 · 2022: 30 · 2021: 23 · 2020: 32 · 2019: 20 · 2018: 8
FWCI
7.38
Type
journal article
Language
en
Open access
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
Funders
  • National Heart, Lung, and Blood Institute (F30HL118923, HHSN268201000045C)
  • National Institute of General Medical Sciences (T32GM008553)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (T32HD075735)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Pluripotent Stem Cells Research
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
Keywords
human pluripotent stem cells, ventricular myocytes, collagen gel, extracellular matrix, cardiac contractility, ejection fraction, action potential, conduction velocity, inotropic agents, drug screening, cardiac electrophysiology
MeSH terms
Action Potentials, Cell Differentiation, Collagen, Heart Ventricles, Humans, Myocardial Contraction, Myocardium, Ventricular Function, Cell Culture Techniques, Hydrogels, Tissue Engineering, Myocytes, Cardiac, Pluripotent Stem Cells, Biomimetic Materials, Electrophysiological Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-09-28.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-09-28.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review