Development of an accurate oscillometric blood pressure device for low resource settings
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess and develop an accurate blood pressure measurement device for use in low resource settings and by untrained staff, according to the World Health Organisation guidelines. METHODS: Ninety-nine adults were recruited to validate the device according to the International Protocol of the European Society of Hypertension. All participants provided written informed consent. Patients with an arrhythmia or unclear Korotkoff sounds were excluded. Nine sequential same-arm measurements were taken from each participant alternating between the test device and mercury sphygmomanometry. Differences between the test device and observers were evaluated according to the criteria of the International Protocol and the Association for the Advancement of Medical Instrumentation. RESULTS: The device failed the first assessment of the oscillometric function and required modification to both the deflation rate and the algorithm to fulfil the International Protocol criteria. It then achieved an acceptable mean difference of -0.7 (4.7) mmHg for systolic and -2.0 (4.6) mmHg for diastolic pressure (oscillometric function) and -1.9 (3.8) mmHg and -0.9 (3.3) mmHg for systolic and diastolic pressures, respectively (auscultatory function). CONCLUSION: The Microlife 3AS1-2 is a semi-automated upper arm device with features consistent with low resource requirements. We successfully developed this device for accurate blood pressure measurement in adults according to the International Protocol, through adjustment of the deflation rate and algorithm. The accuracy and user-friendly design of this low-cost device makes it a highly valuable monitor in clinical practice, particularly in low resource settings and for use by untrained staff.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The device fulfils the World Health Organization requirements for low-resource settings [24].”
In the citing paper
“The device has undergone extensive testing for accuracy and is one of few BP devices to have been validated as accurate in pregnancy (including pre-eclampsia and hypotension) and in non-pregnant adults [11, 23, 24].”
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
OʼBrien, E., Pickering, T., Asmar, R., Myers, M., Parati, G., Staessen, J., Mengden, T., Imai, Y., Waeber, B., Palatini, P., et al. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200202000-00002 · Cited by 744
Prevalence, awareness, treatment and control of hypertension in North America, North Africa and Asia
Whelton, P. K., He, J., & Muntner, P. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001701 · Cited by 170
Reliability of patients measuring blood pressure at home: prospective observational study
Nordmann, A., Frach, B., Walker, T., Martina, B., & Battegay, E. (1999) · BMJ · doi:10.1136/bmj.319.7218.1172 · Cited by 74
Recommendations for blood pressure measuring devices for office/clinic use in low resource settings
Parati, G., Mendis, S., Abegunde, D., Asmar, R., Mieke, S., Murray, A., Shengelia, B., Steenvoorden, G., Van Montfrans, G., & O??Brien, E. (2005) · Blood Pressure Monitoring · doi:10.1097/00126097-200502000-00002 · Cited by 60
Self measured and ambulatory blood pressure in assessing the ‘white-coat’ phenomenon
Parati, G., & Stergiou, G. S. (2003) · Journal of Hypertension · doi:10.1097/00004872-200304000-00005 · Cited by 51
Cited by
Shock index: an effective predictor of outcome in postpartum haemorrhage?
Nathan, H., El Ayadi, A., Hezelgrave, N., Seed, P., Butrick, E., Miller, S., Briley, A., Bewley, S., & Shennan, A. (2015) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.13206 · Cited by 161
Self-citationA core outcome set for pre‐eclampsia research: an international consensus development study
Duffy, J., Cairns, A., Richards‐Doran, D., van 't Hooft, J., Gale, C., Brown, M., Chappell, L., Grobman, W., Fitzpatrick, R., Karumanchi, S., et al. (2020) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.16319 · Cited by 154
“Researchers were recruited through participation in ongoing pre-eclampsia research studies including: (1) community blood pressure monitoring in rural Africa and Asia;(13) (2) detection of underlying pre-eclampsia study, development and validation of a prediction model for risk of complications in early-onset preeclam…”
MethodEl Ayadi, A. M., Nathan, H. L., Seed, P. T., Butrick, E. A., Hezelgrave, N. L., Shennan, A. H., & Miller, S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148729 · Cited by 121
Self-citationPadwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
The assessment of blood pressure in pregnant women: pitfalls and novel approaches
Hurrell, A., Webster, L., Chappell, L. C., & Shennan, A. H. (2021) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2020.10.026 · Cited by 81
Self-citationNathan, H. L., Seed, P. T., Hezelgrave, N. L., de Greeff, A., Lawley, E., Anthony, J., Steyn, W., Hall, D. R., Chappell, L. C., & Shennan, A. H. (2019) · Acta Obstetricia Et Gynecologica Scandinavica · doi:10.1111/aogs.13626 · Cited by 76
Self-citationPoint-of-care diagnostics to improve maternal and neonatal health in low-resource settings
Majors, C. E., Smith, C. A., Natoli, M. E., Kundrod, K. A., & Richards-Kortum, R. R. (2017) · Lab on a Chip · doi:10.1039/c7lc00374a · Cited by 57
Vousden, N., Lawley, E., Nathan, H. L., Seed, P. T., Gidiri, M. F., Goudar, S., Sandall, J., Chappell, L. C., Shennan, A. H., Kachinjika, M., et al. (2019) · The Lancet Global Health · doi:10.1016/s2214-109x(18)30526-6 · Cited by 48
Self-citationthe CLIP Working Group, Nathan, H. L., Boene, H., Munguambe, K., Sevene, E., Akeju, D., Adetoro, O. O., Charanthimath, U., Bellad, M. B., de Greeff, A., et al. (2018) · Reproductive Health · doi:10.1186/s12978-017-0450-y · Cited by 41
“It meets the World Health Organization’s criteria for low-resource settings, being robust and portable, having low power requirements (charging through a microUSB port), requiring minimal calibration, and being affordable at $25 USD per unit [5].”
Self-citationNathan, H. L., Seed, P. T., Hezelgrave, N. L., De Greeff, A., Lawley, E., Anthony, J., Hall, D. R., Steyn, W., Chappell, L. C., & Shennan, A. H. (2018) · Pregnancy Hypertension · doi:10.1016/j.preghy.2017.11.003 · Cited by 40
Self-citationNathan, H. L., Vousden, N., Lawley, E., de Greeff, A., Hezelgrave, N. L., Sloan, N., Tanna, N., Goudar, S. S., Gidiri, M. F., Sandall, J., et al. (2018) · BMJ Innovations · doi:10.1136/bmjinnov-2017-000235 · Cited by 31
Self-citationon behalf of the CRADLE Trial Collaborative Group, Vousden, N., Lawley, E., Seed, P. T., Gidiri, M. F., Charantimath, U., Makonyola, G., Brown, A., Yadeta, L., Best, R., et al. (2019) · Implementation Science · doi:10.1186/s13012-019-0885-3 · Cited by 31
Self-citationon behalf of the CRADLE Trial Collaborative Group, Vousden, N., Lawley, E., Nathan, H. L., Seed, P. T., Brown, A., Muchengwa, T., Charantimath, U., Bellad, M., Gidiri, M. F., et al. (2018) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-018-1737-x · Cited by 30
Self-citationInnovations in vital signs measurement for the detection of hypertension and shock in pregnancy
Vousden, N., Nathan, H. L., & Shennan, A. H. (2018) · Reproductive Health · doi:10.1186/s12978-018-0533-4 · Cited by 29
“It has been validated as accurate outside of pregnancy [22]”
MethodSelf-citationStergiou, G. S., Karpettas, N., Atkins, N., & O'Brien, E. T. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32834331e7 · Cited by 22
Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings
McLaren, Z. M., Sharp, A. R., Hessburg, J. P., Sarvestani, A. S., Parker, E., Akazili, J., Johnson, T. R. B., & Sienko, K. H. (2017) · Development Engineering · doi:10.1016/j.deveng.2017.06.002 · Cited by 21
and the Community Level Interventions for Pre-eclampsia (CLIP) India Feasibility Working Group, Charantimath, U., Vidler, M., Katageri, G., Ramadurg, U. Y., Karadiguddi, C., Kavi, A. J., Joshi, A. M., Mungarwadi, G., Bannale, S., et al. (2018) · Reproductive Health · doi:10.1186/s12978-018-0532-5 · Cited by 23
“This handheld device can be used effectively by unskilled personnel after minimal training [20, 21].”
BackgroundNathan, H. L., Duhig, K. E., Vousden, N., Lawley, E., Seed, P. T., Sandall, J., Bellad, M. B., Brown, A. C., Chappell, L. C., Goudar, S. S., et al. (2018) · Trials · doi:10.1186/s13063-018-2581-z · Cited by 20
“The device fulfils the World Health Organisation requirements for automated devices used in low-resource settings [13].”
MethodSelf-citationGiblin, L., Vousden, N., Nathan, H. L., Gidiri, F., Goudar, S. S., Charantimath, U., Sandall, J., Seed, P. T., Chappell, L. C., & Shennan, A. H. (2021) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-021-03796-4 · Cited by 17
Self-citationvon Dadelszen, P., Magee, L. A., Payne, B. A., Dunsmuir, D. T., Drebit, S. K., Dumont, G. A., Miller, S., Norman, J. E., Pyne‐Mercier, L., Shennan, A. H., et al. (2015) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2015.02.008 · Cited by 15
Self-citationAdepoju, A., Vidler, M., Akadri, A. A., Jaiyesimi, E., Nwankpa, C. C., Odubena, O. O., Sharma, S., Li, L., Tu, D. K., Drebit, S. K., et al. (2021) · Pregnancy Hypertension · doi:10.1016/j.preghy.2021.05.005 · Cited by 12
Self-citationLombardi, C., Picone, D. S., Sharman, J. E., Campbell, N. R. C., Farias, R. F., Guerre, S., Gittens, A., Paccot, M., Villacres, N., González, Y. V., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00706-9 · Cited by 12
“The search led to choosing a validated semiautomatic BPMD with rechargeable batteries that is accurate in pregnancy and meets the WHO criteria for use in a low-resource setting [19].”
MethodBaker, E. C., Hezelgrave, N. L., Magesa, S., Edmonds, S., de Greeff, A., & Shennan, A. H. (2012) · Tropical Doctor · doi:10.1258/td.2011.110352 · Cited by 9
Self-citationRidout, A. E., Moses, F. L., Herm-Singh, S., Turienzo, C. F., Seed, P. T., Goodhart, V., Vousden, N., Sam, B., Momoh, M., Kamara, D., et al. (2023) · Trials · doi:10.1186/s13063-023-07587-4 · Cited by 8
“The device has undergone extensive testing for accuracy and is one of few BP devices to have been validated as accurate in pregnancy (including pre-eclampsia and hypotension) and in non-pregnant adults [11, 23, 24].”
MethodSelf-citationRidout, A. E., Moses, F., Herm-Singh, S., Beoku-Betts, C., Businge, E., Turienzo, C. F., Goodhart, V., Hurrell, A., Kamara, D., Kamara, J., et al. (2025) · The Lancet Obstetrics Gynaecology & Women s Health · doi:10.1016/j.lanogw.2025.09.003 · Cited by 6
Self-citationDind, A., Short, A. E., Ekholm, J., & Holdgate, A. (2011) · International Journal of Nursing Practice · doi:10.1111/j.1440-172x.2011.01958.x · Cited by 6
Reverse innovation in maternal health
Firoz, T., Makanga, P. T., Nathan, H. L., Payne, B. A., & Magee, L. A. (2017) · Obstetric Medicine · doi:10.1177/1753495x17700515 · Cited by 7
Self-citationde Greeff, A., & Shennan, A. H. (2015) · Tropical Doctor · doi:10.1177/0049475515581542 · Cited by 5
Self-citationPadwal, R. S., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A. O., Cruickshank, J. K., Stergiou, G. S., Rakotz, M., Wozniak, G., et al. (2020) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2020.88 · Cited by 8
Kuhrt, K., Seed, P. T., & Shennan, A. H. (2023) · Tropical Doctor · doi:10.1177/00494755221134975 · Cited by 1
Self-citationThe challenge of measuring blood pressure in low-resource settings
Roberts, J. M., & Assibey‐Mensah, V. (2019) · The Lancet Global Health · doi:10.1016/s2214-109x(19)30019-1 · Cited by 1
Hakim, A., & Karim, A. (2011) · Nottingham ePrints (University of Nottingham) · Cited by 1
Hezelgrave, N., Hamid, F., Solangon, A., Bateman, A., Perry, R., Abid, S., Dempsey, A., Saad, L., Ashraf, D. S., Pearce, A., et al. (2012) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fetalneonatal-2012-301809.121
Self-citationGruterich, M., Aelen, P., Wouters, K., & Dellimore, K. H. J. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037102
“Another solution for reducing both the cost and the power consumption of electronic BP monitors is The Microlife 3AS1-2 [8].”
BackgroundKuhrt, K., Seed, P. T., & Shennan, A. H. (2021) · Research Square · doi:10.21203/rs.3.rs-205157/v1
Self-citationKuhrt, K., Seed, P. T., & Shennan, A. H. (2020) · Research Square · doi:10.21203/rs.3.rs-47471/v1
Self-citationEstudo de validação do aparelho automático para medida da pressão arterial visomat® handy IV
Dordetto, P. R. (2010) · doi:10.47749/t/unicamp.2010.772312 · Cited by 2
Metadata
- Authors
- de Greeff, A., Nathan, H., Stafford, N., Liu, B., & Shennan, A. H.
- Affiliations
- St Thomas' Hospital (GB)
- Corresponding author
- Shennan, Andrew H.
- Venue
- Blood Pressure Monitoring
- Published
- 2008-12
- Volume
- 13
- Issue
- 6
- Pages
- 342-348
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2095430479
- Cited by
- 38
- References
- 7
- Citations by year
- 2025: 1 · 2023: 3 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 6 · 2017: 5 · 2016: 1 · 2015: 2 · 2014: 1 · 2012: 2
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Blood Pressure Monitoring (publishedVersion)
- PubMed (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- oscillometric blood pressure measurement, resource-limited settings, measurement algorithm, low-cost medical device, device accuracy
- MeSH terms
- Adult, Algorithms, Arm, Blood Pressure Determination, Calibration, Diastole, Equipment Design, Health Resources, Humans, Oscillometry, Societies, Medical, Systole, Transducers, Reproducibility of Results, Practice Guidelines as Topic, Sphygmomanometers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.