Development of an accurate oscillometric blood pressure device for low resource settings

de Greeff, Annemarie, Nathan, Hannah, Stafford, Nina, Liu, Bing, Shennan, Andrew H. · 2008 · Blood Pressure Monitoring

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess and develop an accurate blood pressure measurement device for use in low resource settings and by untrained staff, according to the World Health Organisation guidelines. METHODS: Ninety-nine adults were recruited to validate the device according to the International Protocol of the European Society of Hypertension. All participants provided written informed consent. Patients with an arrhythmia or unclear Korotkoff sounds were excluded. Nine sequential same-arm measurements were taken from each participant alternating between the test device and mercury sphygmomanometry. Differences between the test device and observers were evaluated according to the criteria of the International Protocol and the Association for the Advancement of Medical Instrumentation. RESULTS: The device failed the first assessment of the oscillometric function and required modification to both the deflation rate and the algorithm to fulfil the International Protocol criteria. It then achieved an acceptable mean difference of -0.7 (4.7) mmHg for systolic and -2.0 (4.6) mmHg for diastolic pressure (oscillometric function) and -1.9 (3.8) mmHg and -0.9 (3.3) mmHg for systolic and diastolic pressures, respectively (auscultatory function). CONCLUSION: The Microlife 3AS1-2 is a semi-automated upper arm device with features consistent with low resource requirements. We successfully developed this device for accurate blood pressure measurement in adults according to the International Protocol, through adjustment of the deflation rate and algorithm. The accuracy and user-friendly design of this low-cost device makes it a highly valuable monitor in clinical practice, particularly in low resource settings and for use by untrained staff.

Overview

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e32830fd07c

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 7 references

Cited by

See all 38

Metadata

Authors
de Greeff, A., Nathan, H., Stafford, N., Liu, B., & Shennan, A. H.
Affiliations
St Thomas' Hospital (GB)
Corresponding author
Shennan, Andrew H.
Venue
Blood Pressure Monitoring
Published
2008-12
Volume
13
Issue
6
Pages
342-348
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2095430479
Cited by
38
References
7
Citations by year
2025: 1 · 2023: 3 · 2022: 1 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 6 · 2017: 5 · 2016: 1 · 2015: 2 · 2014: 1 · 2012: 2
FWCI
0.97
Type
journal article
Language
en
Open access
closed
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
  • Research Portal (King's College London) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
oscillometric blood pressure measurement, resource-limited settings, measurement algorithm, low-cost medical device, device accuracy
MeSH terms
Adult, Algorithms, Arm, Blood Pressure Determination, Calibration, Diastole, Equipment Design, Health Resources, Humans, Oscillometry, Societies, Medical, Systole, Transducers, Reproducibility of Results, Practice Guidelines as Topic, Sphygmomanometers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.