Oscillometric sphygmomanometers: a critical appraisal of current technology

Amoore, John Nicholas · 2012 · Blood Pressure Monitoring

The DOI matches its Crossref record.

Abstract

AIM: Blood pressure (BP), a key vital sign, monitors general health. Oscillometric devices are increasingly used for measurement, although their accuracy continues to be critically debated. A functional block diagram is used to review the components that affect accuracy. METHODS: A block diagram is presented covering the components from cuff to algorithm. The oscillometric waveform is described, considering factors that can alter its shape. Methods used to assess accuracy, including the potential use of simulators, are described. RESULTS AND DISCUSSION: The block diagram focuses attention on cuff, amplifier, signal processing and algorithm. The importance of correct cuff size is emphasized. Accuracy can be affected by the extraction of the oscillometric pulses and the interpolation to compensate for higher deflation rates. Modern electronic amplifiers are assumed to be stable and do not drift, an assumption largely untested. Crucial to accuracy is the algorithm, but there is no standard algorithm and limited theoretical basis, leading to significant measurement errors in groups of patients, even by approved devices. The causes are not well understood, but differences in oscillometric waveform shape between patient groups have been observed and may explain auscultatory-oscillometric differences. The ability of theoretical models to explain the effects of arterial stiffness on BP measurements is discussed. Validation remains statistical though steps have been taken to improve it. CONCLUSION: The indirect nature of BP measurement poses particularly problems for ensuring accuracy. Critical assessment has done much to improve standards, but a solid theoretical understanding of the technique has not been formulated and further work is required.

Overview

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e32835026b0

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Still being checked.

Cited by

See all 50

Metadata

Authors
Amoore, J. N.
Affiliations
University Hospital Crosshouse (GB)
Corresponding author
Amoore, John Nicholas
Venue
Blood Pressure Monitoring
Published
2012-04
Volume
17
Issue
2
Pages
80-88
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2001232250
Cited by
49
References
0
Citations by year
2026: 2 · 2024: 3 · 2023: 2 · 2022: 3 · 2021: 4 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 6 · 2015: 2 · 2014: 4 · 2013: 6 · 2012: 3
FWCI
2.73
Type
journal article
Language
en
Open access
closed
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
blood pressure measurement accuracy, cuff size, measurement algorithm, arterial stiffness, measurement error
MeSH terms
Blood Pressure, Blood Pressure Determination, Humans, Sphygmomanometers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oscillometric sphygmomanometers: a critical appraisal of current technology. https://app.cochat.ai/papers/10.1097/mbp.0b013e32835026b0
The paper
Amoore, J. N. (2012). Oscillometric sphygmomanometers: a critical appraisal of current technology. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e32835026b0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.