Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Cuff blood pressure (BP) is the reference standard for management of high BP, but the method is inaccurate and can lead to BP misclassification. The aims of this study were to determine whether distinctive BP phenotypes exist based on BP transmission (amplification) variability from central-to-peripheral arteries and whether applying one standard cuff BP measurement approach (eg, oscillometry) to all people could discriminate the BP phenotypes. Intra-arterial BP was measured at the ascending aorta and brachial and radial arteries in 126 participants (61±10 years; 69% male) after coronary angiography. Central-to-peripheral systolic BP (SBP) transmission (SBP amplification) was defined by ≥5 mm Hg SBP increase between the aorta-to-brachial or brachial-to-radial arteries. Standard cuff BP was measured 4 different times using 3 different devices. Three independent investigators also provided data (n=255 from 4 studies) using another 3 separate cuff BP devices. Four distinct BP phenotypes were discovered based on variability in SBP amplification: phenotype 1, both aortic-to-brachial and brachial-to-radial SBP amplification; phenotype 2, only aortic-to-brachial SBP amplification; phenotype 3, only brachial-to-radial SBP amplification; and phenotype 4, neither aortic-to-brachial nor brachial-to-radial SBP amplification. Aortic SBP was significantly higher among phenotypes 3 and 4 compared with phenotypes 1 and 2 ( P =0.00074), but this was not discriminated using any standard cuff BP measures ( P =0.31). Data from independent investigators confirmed the key findings. This is the first-in-human discovery of BP phenotypes that have significantly different BPs, but which are not discriminated by standard cuff BP devices used in daily clinical practice. Improved BP device accuracy may be achieved by considering individual phenotypic BP differences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Global, Regional, and National Burden of Cardiovascular Diseases for 10 Causes, 1990 to 2015
Roth, G. A., Johnson, C., Abajobir, A., Abd-Allah, F., Abera, S. F., Abyu, G., Ahmed, M., Aksut, B., Alam, T., Alam, K., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.04.052 · Cited by 3,791
Ettehad, D., Emdin, C. A., Kiran, A., Anderson, S. G., Callender, T., Emberson, J., Chalmers, J., Rodgers, A., & Rahimi, K. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01225-8 · Cited by 3,755
Zhou, B., Bentham, J., Di Cesare, M., Bixby, H., Danaei, G., Cowan, M. J., Paciorek, C. J., Singh, G., Hajifathalian, K., Bennett, J. E., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(16)31919-5 · Cited by 2,579
Self-citationPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Vlachopoulos, C., Aznaouridis, K., O'Rourke, M. F., Safar, M. E., Baou, K., & Stefanadis, C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq024 · Cited by 1,363
Systolic versus diastolic blood pressure and risk of coronary heart disease
Kannel, W. B., Gordon, T., & Schwartz, M. J. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90428-0 · Cited by 925
Kollias, A., Lagou, S., Zeniodi, M. E., Boubouchairopoulou, N., & Stergiou, G. S. (2016) · Hypertension · doi:10.1161/hypertensionaha.115.06066 · Cited by 287
Recommendations for Human Blood Pressure Determinations by Sphygmomanometers
BORDLEY, J., CONNOR, C. A. R., HAMILTON, W. F., KERR, W. J., & WIGGERS, C. J. (1951) · Circulation · doi:10.1161/01.cir.4.4.503 · Cited by 262
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
Self-citation
Cited by
Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84
Self-citationArmstrong, M. K., Schultz, M. G., Picone, D. S., Black, J. A., Dwyer, N., Roberts-Thomson, P., & Sharman, J. E. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12674 · Cited by 59
Self-citationMeasurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Self-citation
Metadata
- Authors
- Picone, D. S., Schultz, M. G., Peng, X., Black, J. A., Dwyer, N., Roberts-Thomson, P., Chen, C.-H., Cheng, H.-M., Pucci, G., Wang, J.-G., & Sharman, J. E.
- Venue
- Hypertension
- Published
- 2018-06
- Volume
- 71
- Issue
- 6
- Pages
- 1239-1247
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2797238620
- Cited by
- 47
- References
- 12
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice. https://app.cochat.ai/papers/10.1161/hypertensionaha.117.10696
- The paper
- Picone, D. S., Schultz, M. G., Peng, X., Black, J. A., Dwyer, N., Roberts-Thomson, P., Chen, C.-H., Cheng, H.-M., Pucci, G., Wang, J.-G., & Sharman, J. E. (2018). Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice. Hypertension. https://doi.org/10.1161/hypertensionaha.117.10696
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.