CoChat

Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice

Open access
Picone, Dean S., Schultz, Martin G., Peng, Xiaoqing, Black, J. Andrew, Dwyer, Nathan, Roberts-Thomson, Philip, Chen, Chen-Huan, Cheng, Hao-Min, Pucci, Giacomo, Wang, Ji-Guang, Sharman, James E. · 2018 · Hypertension
Cited by 47

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Cuff blood pressure (BP) is the reference standard for management of high BP, but the method is inaccurate and can lead to BP misclassification. The aims of this study were to determine whether distinctive BP phenotypes exist based on BP transmission (amplification) variability from central-to-peripheral arteries and whether applying one standard cuff BP measurement approach (eg, oscillometry) to all people could discriminate the BP phenotypes. Intra-arterial BP was measured at the ascending aorta and brachial and radial arteries in 126 participants (61±10 years; 69% male) after coronary angiography. Central-to-peripheral systolic BP (SBP) transmission (SBP amplification) was defined by ≥5 mm Hg SBP increase between the aorta-to-brachial or brachial-to-radial arteries. Standard cuff BP was measured 4 different times using 3 different devices. Three independent investigators also provided data (n=255 from 4 studies) using another 3 separate cuff BP devices. Four distinct BP phenotypes were discovered based on variability in SBP amplification: phenotype 1, both aortic-to-brachial and brachial-to-radial SBP amplification; phenotype 2, only aortic-to-brachial SBP amplification; phenotype 3, only brachial-to-radial SBP amplification; and phenotype 4, neither aortic-to-brachial nor brachial-to-radial SBP amplification. Aortic SBP was significantly higher among phenotypes 3 and 4 compared with phenotypes 1 and 2 ( P =0.00074), but this was not discriminated using any standard cuff BP measures ( P =0.31). Data from independent investigators confirmed the key findings. This is the first-in-human discovery of BP phenotypes that have significantly different BPs, but which are not discriminated by standard cuff BP devices used in daily clinical practice. Improved BP device accuracy may be achieved by considering individual phenotypic BP differences.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.117.10696

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 47

Metadata

Authors
Picone, D. S., Schultz, M. G., Peng, X., Black, J. A., Dwyer, N., Roberts-Thomson, P., Chen, C.-H., Cheng, H.-M., Pucci, G., Wang, J.-G., & Sharman, J. E.
Venue
Hypertension
Published
2018-06
Volume
71
Issue
6
Pages
1239-1247
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2797238620
Cited by
47
References
12
FWCI
4.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice. https://app.cochat.ai/papers/10.1161/hypertensionaha.117.10696
The paper
Picone, D. S., Schultz, M. G., Peng, X., Black, J. A., Dwyer, N., Roberts-Thomson, P., Chen, C.-H., Cheng, H.-M., Pucci, G., Wang, J.-G., & Sharman, J. E. (2018). Discovery of New Blood Pressure Phenotypes and Relation to Accuracy of Cuff Devices Used in Daily Clinical Practice. Hypertension. https://doi.org/10.1161/hypertensionaha.117.10696

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.