Accepted but Unacceptable: Peripheral IV Catheter Failure
The DOI matches its Crossref record, with a small difference in title or year; 144 of the 148 references it cites were found in a registry or an index.
Abstract
Peripheral intravenous (IV) catheter insertion, the most common invasive hospital procedure performed worldwide, is associated with a variety of complications and an unacceptably high overall failure rate of 35% to 50% in even the best of hands. Catheter failure is costly to patients, caregivers, and the health care system. Although advances have been made, analysis of the mechanisms underlying the persistent high rate of peripheral IV failure reveals opportunities for improvement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although peripheral intravenous cannulation is the most common invasive hospital procedure performed worldwide, it is associated with an unacceptable high overall failure rate [5,6].”
Citations
Cites
Horan, T. C., Andrus, M., & Dudeck, M. A. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2008.03.002 · Cited by 6,626
Wisplinghoff, H., Bischoff, T., Tallent, S. M., Seifert, H., Wenzel, R. P., & Edmond, M. B. (2004) · Clinical Infectious Diseases · doi:10.1086/421946 · Cited by 4,496
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Biofilms and Device-Associated Infections
Donlan, R. M. (2001) · Emerging Infectious Diseases · doi:10.3201/eid0702.010226 · Cited by 1,504
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W. J., Veeh, R., Shirtliff, M. E., Pasmore, M. E., Post, C., & Ehrlich, G. D. (2003) · Journal of Clinical Investigation · doi:10.1172/jci20365 · Cited by 649
How Staphylococcus aureus biofilms develop their characteristic structure
Periasamy, S., Joo, H.-S., Duong, A. C., Bach, T.-H. L., Tan, V. Y., Chatterjee, S. S., Cheung, G. Y. C., & Otto, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1115006109 · Cited by 640
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W., Veeh, R., Shirtliff, M., Pasmore, M., Post, C., & Ehrlich, G. (2003) · Journal of Clinical Investigation · doi:10.1172/jci200320365 · Cited by 630
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Research works printed but not linked: 3
- Carlquist, 1981, Understanding the psychological needs of the patient on IV therapy: a stress-reducing approach., NITA, 4, 368
- Sarafzadeh, 2012, Evaluation of the severity of peripheral intravenous catheter related phlebitis during one year in an Iranian educational hospital, Kerman, Iran., Ann Biol Res, 3, 4741
- Ryder, 2005, Catheter related infections: its all about biofilm., Top Adv Pract Nurs e-J, 5, 1
Cited by
Items 201–300 of 481
Sharma, M., Paudel, S., Shrestha, U., & Sitaula, B. (2022) · Journal of Nepal Medical Association · doi:10.31729/jnma.7222 · Cited by 8
Implementation of a Vascular Access Experience Program to Train Unit-Based Vascular Access Champions
Goodfriend, L., Kennedy, S., Hein, A., & Baker, R. (2020) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000373 · Cited by 11
“Finally, Glover et al7 stated there are 4 types of learning: (1) experiential, hands-on simulated practice (body/kinesthetic learners); (2) text-based and narrated online instruction (verbal/linguistic learners); (3) animations and videos (visual learners); and (4) classroom facilitation that emphasizes individual lea…”
BackgroundMielke, N., O’Sullivan, C., Xing, Y., & Bahl, A. (2024) · International Journal for Equity in Health · doi:10.1186/s12939-024-02213-4 · Cited by 7
“These failures cause immediate patient discomfort and increased clinical workload and have broader implications, such as prolonged hospital stays and delays in critical treatments [2].”
BackgroundYasuda, H., Rickard, C. M., Mimoz, O., Marsh, N. M., Schults, J. A., Drugeon, B., Kashiura, M., Kishihara, Y., Shinzato, Y., Koike, M., et al. (2024) · The Journal of Critical Care Medicine · doi:10.2478/jccm-2024-0028 · Cited by 7
“However, given that phlebi-tis has resulted in a need for skin grafting, progressed to necrosis, and increased the risk of death in severe cases [11], a predictive model for phlebitis would aid in the removal of PIVCs when clinically indicated rather than at predesignated time periods.”
BackgroundFerraz‐Torres, M., Sancho-Sena, E., Corcuera-Martinez, M. I., Martínez-García, O., & Suárez-Mier, M. B. (2024) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000561 · Cited by 7
“9,10 Numerous established guides have identified the best evidence for the development of universal measures for the care of PIVCs, such as inserting the device in the upper extremity, preparing the skin with alcoholic chlorhexidine >0.5%, maintaining aseptic technique when inspecting and caring…”
InfluentialKleidon, T. M., Takashima, M., Rickard, C. M., Schults, J. A., Bulmer, A. C., & Ullman, A. J. (2025) · Journal of Advanced Nursing · doi:10.1111/jan.16795 · Cited by 8
“In addition to the increased clinical workload and healthcare costs (Goff et al. 2013; Helm et al. 2015; Kleidon et al. 2019), these insertion failures result in immeasurable patient harm, including increased complications (extravasation and infection) (Kleidon et al. 2019; Morrell 2020; Reigart et…”
Corley, A., Ullman, A. J., Marsh, N. M., Larsen, E. N., Mihala, G., Harris, P. N. A., & Rickard, C. M. (2020) · British Journal of Nursing · doi:10.12968/bjon.2020.29.19.s40 · Cited by 7
“Furthermore, PIVC failure is costly to the healthcare institution due to the human and material resources required to replace failed PIVCs, in addition to the cost of treating PIVC complications and any sequelae (Helm et al., 2015).”
BackgroundCline, G. J., Pohlod, V., Burger, K. J., & Amankwah, E. K. (2021) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000431 · Cited by 7
Kristoff, K. C., Wang, R., Munson, D., Dysart, K., Stracuzzi, L. A., Wade, K., & Birnbaum, S. (2021) · Advances in Neonatal Care · doi:10.1097/anc.0000000000000941 · Cited by 7
Pre-hospital peripheral intravenous catheter insertion practice: An integrative review
Golling, E., van de Mortel, T., Barr, N., & Zimmerman, P.-A. P. (2022) · Australasian Emergency Care · doi:10.1016/j.auec.2022.08.006 · Cited by 8
Peripheral intravenous catheter insertion and therapy administration: simulator learning.
Simeone, S., Gargiulo, G., Bosco, V., Mercuri, C., Botti, S., Candido, S., Paonessa, G., Bruni, D., Serra, N., & Doldo, P. (2023) · PubMed Central · doi:10.23750/abm.v94i3.14079 · Cited by 11
Guillén, M. B., Rodríguez, J. T., Alfonsel, J. N., Cárdenas‐Rebollo, J. M., & Ayuso‐Sacido, Á. (2024) · Healthcare · doi:10.3390/healthcare12161558 · Cited by 7
Vascular access device selection: Optimizing patient outcomes - Part 1
Nickel, B. (2024) · Nursing · doi:10.1097/nsg.0000000000000050 · Cited by 7
Quici, M., Martini, E., Giustivi, D., Calloni, M. V., Cogliati, C. B., Taino, A., Foschi, A., Gori, A., Zappa, P., Casella, F., et al. (2025) · Scientia Pharmaceutica · doi:10.3390/scipharm93010013 · Cited by 9
“Repeated contact of the infusate with a specific point of the venous wall can lead to inflammation (phlebitis), thrombosis, and leakage of the infusate into extravascular tissues (infiltration) [3].”
PUNÇÃO VENOSA PERIFÉRICA GUIADA POR ULTRASSONOGRAFIA: PREVALÊNCIA DE SUCESSO E FATORES ASSOCIADOS
de Oliveira, A. M., Danski, M. T. R., & Pedrolo, E. (2017) · Cogitare Enfermagem · doi:10.5380/ce.v22i3.49599 · Cited by 12
Higgins, N., Iu, P., Carr, P. J., Ware, R. S., & van Zundert, A. A. J. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.15654 · Cited by 7
“A PIVC sited in the forearm is 60% less likely to fail due to accidental dislodgement than if the back of the hand is selected, it is also easier to secure and is more comfortable (Alexander et al., 2011; Carr et al., 2018; Dillon et al., 2008; Helm et al., 2015; Marsh et al., 2017; Wallis et al., 2014).”
BackgroundShrestha, S., Vieler, J., Haug, N. J., Afset, J. E., Høvik, L. H., Lydersen, S., & Gustad, L. T. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-048370 · Cited by 7
The use of heat to deliver fentanyl via pulmonary drug delivery
Vazda, A., Xia, W., & Engqvist, H. (2021) · International Journal of Pharmaceutics X · doi:10.1016/j.ijpx.2021.100096 · Cited by 7
“Particles with a size greater than 5 μm tend not to pass the oropharyngeal cavity (Heyder et al., 1986).”
BackgroundSantos‐Costa, P., Sousa, L. B., Marques, I. A., Salgueiro‐Oliveira, A., Parreira, P., Vieira, M. M. D. S., & Graveto, J. (2020) · Revista de Enfermagem Referência · doi:10.12707/rv20004 · Cited by 7
Poormohamadi, M., Farsi, Z., & Rajai, N. (2017) · Military Caring Sciences · doi:10.29252/mcs.4.1.19 · Cited by 7
Ford, C. (2019) · British Journal of Nursing · doi:10.12968/bjon.2019.28.13.838 · Cited by 7
Vancomycin infusion methods on phlebitis prevention in children
Talakoub, S., Tork-Torabi, M., Namnabati, M., & Allameh, Z. S. (2019) · Iranian Journal of Nursing and Midwifery Research · doi:10.4103/ijnmr.ijnmr_149_18 · Cited by 7
Fabrication And Evaluation Of Simple Tissue-Mimicking Phantoms For Electrical Impedance Sensing
Goehring, C., Liu, J., Schiele, F., Möeller, K., & Pott, P. P. (2021) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes48179.2021.9398842 · Cited by 7
Taşdelen, Y., & Çağlar, S. (2020) · Journal of Nursing Care Quality · doi:10.1097/ncq.0000000000000511 · Cited by 6
A Critical Appraisal of Variability in Informed Consent for Vascular Access Procedures
Hotchkiss, J. B., & Thompson, J. (2021) · Journal of the Association for Vascular Access · doi:10.2309/java-d-21-00007 · Cited by 6
The Clinical Nurse Specialist Role and its Relevance to Vascular Access: A Canadian Perspective
Raynak, A., & Wood, B. (2021) · Journal of the Association for Vascular Access · doi:10.2309/java-d-21-00014 · Cited by 6
Extravasation Screening and Severity Prediction from Skin Lesion Image using Deep Neural Networks
Munthuli, A., Intanai, J., Tossanuch, P., Pooprasert, P., Ingpochai, P., Boonyasatian, S., Kittithammo, K., Thammarach, P., Boonmak, T., Khaengthanyakan, S., et al. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871115 · Cited by 7
“However, extravasation occurs when fluid is a vesicant and may spread to nerves, ligaments, and joints of organs, causing irritation and injury [5], [6].”
BackgroundIori, M., Grassi, E., Piergallini, L., Meglioli, G., Botti, A., Sceni, G., Cucurachi, N., Verzellesi, L., Finocchiaro, D., Versari, A., et al. (2023) · EJNMMI Physics · doi:10.1186/s40658-023-00556-5 · Cited by 6
“Although rare, extravasation events can occur during administration due to improper placement of the IV access device or by a failure of the vessel wall [6, 7].”
BackgroundEducating for capability and preparing for practice: Integrating theory and skills
Carter, H., Hanks, S., Johnson, R., & Gale, T. C. E. (2024) · The Clinical Teacher · doi:10.1111/tct.13725 · Cited by 6
“7 The needs assessment was led by two highly experienced, master ’ s level clinical educators, based on their experience of teaching skills such as cannulation.”
BackgroundOptimizing peripheral I.V. access outcomes – Part 2
Nickel, B. (2024) · Nursing · doi:10.1097/nsg.0000000000000069 · Cited by 6
Technical Note: Characterization of technology to detect residual injection site radioactivity
Knowland, J., Lipman, S. L., Lattanze, R., Kingg, J., Ryan, K. A., & Perrin, S. (2019) · Medical Physics · doi:10.1002/mp.13536 · Cited by 6
“During the intravenous access or injection, radiotracer can be inadvertently deposited into the tissue surrounding the vein.(49) This is known as an infiltration and can affect the net activity available for circulation or alter the kinetics of availability.”
Evaluation of the Use of Open Versus Closed Short Peripheral Catheters on Catheter Dwell Time
Penoyer, D., Fowler, S. A., & Bennett, M. (2019) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000345 · Cited by 6
Optimizing the Effectiveness of Short Peripheral Catheters
Kollar, C. (2021) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000426 · Cited by 7
“The 2016 Standards recommended the following: (1) insert an SPC in the forearm and/or nondominant extremity, (2) avoid areas of flexion, (3) choose a 20- to 24-gauge catheter for most IV therapies, (4) select an adequate length catheter for deeper veins, and (5) consider using an ESD.”
BackgroundMethodInfluentialSolving the problem of IV dislodgement
Munoz-Mozas, G. (2022) · British Journal of Nursing · doi:10.12968/bjon.2022.31.2.s4 · Cited by 6
Schettini, F., Ferrario, L. B., Foglia, E., Garagiola, E., Parodi, L., Cavagnaro, P., Garra, L., Valeri, A., Cirone, M., & Rapetti, R. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263227 · Cited by 7
Torossian, K., Benayoun, S., Otténio, M., & Brulez, A. (2019) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411919864786 · Cited by 7
“Helm et al. 2 observed a PVCI failure rate of 35% to 50%, leading to a premature removal before the intended dwell time of the catheter.”
Marsh, N. M., Larsen, E. N., O’Brien, C., Peach, H., Keogh, S. J., Davies, K. M., Mihala, G., Hewer, B., Booker, C., McCarthy, A. L., et al. (2023) · Journal of Clinical Nursing · doi:10.1111/jocn.16852 · Cited by 6
“This causes discomfort to the patient and increased cost (both in products and in staff time) to organisations (Cooke et al., 2018 ; Helm et al., 2015 ).”
BackgroundBahl, A., Clement, V., DiLoreto, E., Mielke, N., Carr, A., Panza, G. A., & Gibson, S. M. (2024) · The Journal of Vascular Access · doi:10.1177/11297298231222052 · Cited by 5
“1,10 While a minority of failure is related to improper flushing (i.e. occlusion) or kinking (i.e. mechanical failure) of the PIVC, a major contributor to the more frequently occurring complications may be related to the PIVC movement and injury to the vein wall.”
Mielke, N., Xing, Y., Gibson, S. M., DiLoreto, E., & Bahl, A. (2023) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s435628 · Cited by 5
“5 In contrast, the strong results of this study emphasized the vital importance of proper education and training in shaping frontline ED clinicians to deliver the best vascular access outcomes for patients throughout their hospital stay.”
ResultPiekiełko, P., Mucha, A., Stawowczyk, E., & Wójkowska‐Mach, J. (2024) · Antibiotics · doi:10.3390/antibiotics13070664 · Cited by 5
Performance and safety of PowerPICC catheters and accessories: a prospective observational study
Troubil, M., Capozzoli, G., Mussa, B., Hodne, M. J., Hoerauf, K. H., & Alsbrooks, K. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-081288 · Cited by 5
Periferik İntravenöz Kateter Uygulamasında Hemşirelik Bakımı: Kanıta Dayalı Uygulamalar
ÇELİK, Ş., & Avşar, G. (2021) · Sağlık Bilimleri Üniversitesi Hemşirelik Dergisi · doi:10.48071/sbuhemsirelik.962136 · Cited by 7
Smith, E., & Irimia, V. (2023) · British Journal of Nursing · doi:10.12968/bjon.2023.32.14.s14 · Cited by 5
Masamoto, T., & Yano, R. (2020) · Japan Journal of Nursing Science · doi:10.1111/jjns.12379 · Cited by 5
Effective utilisation of rapid infusion catheters in perioperative care: a narrative review
Scorer, A., Chahal, R., Ellard, L. M., Myles, P. S., & Bradley, W. P. L. (2025) · BJA Open · doi:10.1016/j.bjao.2024.100365 · Cited by 5
Yasuda, H., Rickard, C. M., Schults, J. A., Marsh, N. M., Kashiura, M., Kishihara, Y., Shinzato, Y., Amagasa, S., Moriya, T., Kotani, Y., et al. (2025) · Emergency Medicine International · doi:10.1155/emmi/4457109 · Cited by 8
Hartley, T., Kluszczynski, J., & Broadhurst, D. (2025) · British Journal of Nursing · doi:10.12968/bjon.2025.0546 · Cited by 4
Drugeon, B., Marjanovic, N. S., Mihala, G., Seguin, S., Batiot, G., Rouschmeyer, V., Gerlier, C., Peyrony, O., Lefebvre, S., Guénézan, J., et al. (2026) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2026.101674 · Cited by 4
Peripheral intravenous catheter-induced phlebitis in a tertiary hospital of Karachi: a cohort study
Yaqoob, M., Masih, S., Rasheed, A., Shah, Y., Uddin, N., Siddiqui, F., Rehan, M., Khan, R. A., Ahmed, F., Rehan, M., et al. (2024) · British Journal of Nursing · doi:10.12968/bjon.2024.0235 · Cited by 4
Peralta, M., Nichelason, A. E., & Trepanier, L. A. (2025) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x251334279 · Cited by 4
Hu, A.-Z., Yin, X., Chen, L., Lu, L.-A., Lai, H.-L., & Liu, L. (2025) · Scientific Reports · doi:10.1038/s41598-025-03430-9 · Cited by 4
“International studies indicate that the overall incidence of PIVC failure ranges from 35 to 50% 8 , underscoring the imperative for increased clinical management and monitoring protocols aimed at reducing complications rates while improving patient safety and satisfaction.”
Strategically Applying New Criteria for Use Improves Management of Peripheral Intravenous Catheters
Loudermilk, R. A., Steffen, L. E., & McGarvey, J. (2018) · Journal for Healthcare Quality · doi:10.1097/jhq.0000000000000148 · Cited by 4
A device for improving the visual clarity and dimension of veins
Asrar, M., Al‐Habaibeh, A., Shakmak, B., & Shaw, S. J. (2018) · British Journal of Nursing · doi:10.12968/bjon.2018.27.19.s26 · Cited by 4
Lešnik, A., Gorenjak, M., Žumer, S., Zorčič, V., Mišanović, Ž., Majhenič, M., Podstenšek, A., Toplak, M., Fekonja, U., & Markota, A. (2021) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2021.01.088 · Cited by 4
Impacting Neonatal Patient Care: Reducing Needle Sticks, with an Extended Dwell CatheterCE
Daly, T. M., & Girgenti, C. (2021) · Journal of the Association for Vascular Access · doi:10.2309/java-d-21-00008 · Cited by 4
Collaborative Nurse–Engineer Product Innovation
Giuliano, K. K., & Landsman, K. (2022) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000842268.38546.af · Cited by 4
İbil, N., & Uysal, N. (2021) · Celal Bayar Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi · doi:10.34087/cbusbed.772071 · Cited by 4
Drugeon, B., Schults, J. A., Ray‐Barruel, G., Xu, G. (., Ball, D., Yasuda, H., Drugeon, R., Mercier, J., Mihala, G., Barker, N., et al. (2026) · Journal of Advanced Nursing · doi:10.1111/jan.17007 · Cited by 3
Peripheral Intravenous Cannula Usage in the Emergency Department
Stanley, A. K., Barnett‐Vanes, A., & Reed, M. J. (2020) · Emergency Care Journal · doi:10.4081/ecj.2020.9205 · Cited by 3
Implementing a Midline Catheter Program in an Acute Care Hospital: Process and Outcomes
Keleekai-Brapoh, N., Fernandes, N., Richards, A., & Gilpin, C. (2021) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000437 · Cited by 3
Doyle, B. J., Kelsey, L. J., Shelverton, C., Abbate, G., Ainola, C., Sato, N., Livingstone, S., Bouquet, M., Passmore, M. R., Wilson, E., et al. (2022) · The Journal of Vascular Access · doi:10.1177/11297298221127760 · Cited by 3
“1,5 Commercially, there are a plethora of differently designed PIVCs available to clinicians.”
A temperature-sensitive, high-adhesion medical tape: a comparative, single-blind clinical trial
Swanson, S., Luu, V., Smith, R., Gross, A., Tudor, J., MacKenzie, J. D., Taroc, A., Gow, K. W., Nelson, L. Y., & Seibel, E. J. (2023) · Journal of Wound Care · doi:10.12968/jowc.2023.32.10.665 · Cited by 4
Effect of Structured Nursing Education Programs in Prevention of Admitted Patients’ Phlebitis
بقایی, ر., Khalkhali, H. R., & Rezaeifar, P. (2018) · Preventive Care In Nursing and Midwifery Journal · doi:10.29252/pcnm.8.3.42 · Cited by 3
“Jackson's Phlebitis Scale (VIP): degree Symptoms 0 degree IV site appears healthy 1 degree One of the following is evident Slight pain near IV site Slight redness near IV site 2 degree Two of the following are evident Pain at IV site Erythema Swelling 3 degree All of the following signs are evident and extensive Pain…”
BackgroundInfluentialRe‐evaluating expanding intravenous catheters in medical practice
Vazquez, R., Tennankore, R., Shikanov, A., Mermel, L. A., Love, B. J., & Burns, M. L. (2021) · Health Science Reports · doi:10.1002/hsr2.318 · Cited by 3
“The broad goal of any catheter is to not activate platelets and T cells, resulting in clots or triggering inflammation in the catheterized vein.(2) Finally, intravascular devices, especially indwelling catheters, carry nontrivial risks for infection and that risk rises the longer they are inserted.”
BackgroundAkman, Ö., Yıldırım, D., Sarıkaya, A., & Öztürk, C. (2022) · Cyprus Journal of Medical Sciences · doi:10.4274/cjms.2021.2285 · Cited by 3
“It was reported that a factor causing this problem is the lack of knowledge and skills of the nurses applying the catheters.(11) One of the proposed solutions for reducing the failure rate and reducing complications is to enhance the nurses’ training in PIVC placement.”
BackgroundStatistical Analysis of Multispectral NIR Images for Vein Detection
Dave, J., Chand, S., Rahul, G. S., Raj, A., Preejith, S. P., & Sivaprakasam, M. (2023) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea57477.2023.10171947 · Cited by 3
“According to [1], about 60-90% of patients require IV cannulations for providing nutrition as IV fluids, collecting blood samples for diagnostic purposes or administering medicine for procedures like chemotherapy or dialysis.”
BackgroundA guide to cannulation in adults
Ford, C. (2023) · British Journal of Nursing · doi:10.12968/bjon.2023.32.19.s6 · Cited by 3
Multispectral Imaging for Vein Localization and Contrast Enhancement
Dave, J., Chand, S., Rahul, G. S., Raj, A., Preejith, S. P., & Sivaprakasam, M. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341080 · Cited by 3
“Intravenous (IV) catheterization is the most common procedure in hospitals, with 60-90% of inpatients requiring vein puncture [1].”
BackgroundXu, H. G., Corley, A., Ware, R. S., Nghiem, S. H., Stirling, S., Wang, C., & Marsh, N. M. (2024) · British Journal of Nursing · doi:10.12968/bjon.2024.33.7.s28 · Cited by 3
Infection control when delivering intravenous therapy in the community setting
Higginson, R. (2017) · British Journal of Community Nursing · doi:10.12968/bjcn.2017.22.9.426 · Cited by 3
Clinical use of closed-system safety peripheral intravenous cannulas
Barton, A. (2018) · British Journal of Nursing · doi:10.12968/bjon.2018.27.8.s22 · Cited by 3
Biomechanics of the medical gesture for a peripheral venous catheter insertion
Torossian, K., Otténio, M., Brulez, A., Lafon, Y., & Benayoun, S. (2019) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1714918 · Cited by 3
Intervención educativa para la prevención de complicaciones de accesos venosos periféricos
Chumapi, C. M. L. (2021) · Pro Sciences Revista de Producción Ciencias e Investigación · doi:10.29018/issn.2588-1000vol5iss40.2021pp131-150 · Cited by 3
Predicting difficult peripheral venous access in hospitalized adult patients: A scoping review
Nannini, F., Mancin, S., Morales Palomares, S., Pettinari, G., Cosmai, S., Lopane, D., Cattani, D., & Mazzoleni, B. (2026) · The Journal of Vascular Access · doi:10.1177/11297298251374415 · Cited by 2
“11,12 For these reasons, ineffective peripheral venipuncture may necessitate the use of central venous catheters (CVCs), which are associated with higher costs and increased risks of complications.”
Comparing Midline and Peripherally Inserted Central Catheters: A Randomized Feasibility Trial
Burek, A. G., Porada, K., Plunk, M. R., Bauer, S. C., Liegl, M., Pan, A. Y., Flynn, K. E., Brousseau, D. C., Gedeit, R., & Ullman, A. J. (2025) · Hospital Pediatrics · doi:10.1542/hpeds.2024-007894 · Cited by 2
İncekar, M. Ç., Yıldız, S., Gül, Y., & Uzunhan, O. (2025) · Enfermería Clínica (English Edition) · doi:10.1016/j.enfcle.2025.102147 · Cited by 2
Sakakida, T., Fukahori, S., Mizuno, T., Ishizuka, Y., Wakabayashi, M., Kodama, H., Narita, Y., Masuishi, T., Honda, K., Kadowaki, S., et al. (2025) · The Oncologist · doi:10.1093/oncolo/oyaf108 · Cited by 2
Drugeon, B., Rickard, C. M., Peters, N., Chopra, V., & Mimoz, O. (2025) · Journal of Advanced Nursing · doi:10.1111/jan.70347 · Cited by 2
“However, its insertion is not without risk, with first-attempt failure rates reaching 40% and post-complications occurring in 50% of cases (Witting 2012; Helm et al. 2015; Paterson et al. 2022; Sebbane et al. 2013; Lapostolle et al. 2007).”
Hartley, T., Kluszczynski, J., & Broadhurst, D. (2024) · Vascular Access · doi:10.5737/va.v18.i3.49 · Cited by 2
Indian Expert Consensus on the Selection of Vascular Access Devices in Oncology Patients
Somashekhar, S. P., Gupta, B., Vijay, D. G., Kadayaprath, G., Somashekhar, M., Rao, M., Chowdhary, R., Prasad, R., Patni, S., Alurkar, S. S., et al. (2025) · Indian Journal of Surgical Oncology · doi:10.1007/s13193-025-02466-7 · Cited by 2
“[44–47] Frequent PIVC replacements add significant expenses, each costing up to US$35 in the US and €10.84 in Europe .”
InfluentialFibroblastic sleeve and short peripheral catheter failures: Impact of risk factors
Meschia, A., Giustivi, D., Celano, R., Cattalani, M., Camilli, C., Bartoli, A., Urso, F., Calloni, M. V., Cirigliano, F., Taino, A., et al. (2025) · The Journal of Vascular Access · doi:10.1177/11297298251395371 · Cited by 2
Moon, J. T., Li, H., Patel, E., Zhang, N., Naidu, S., Ma, Q., Zhou, C. R., Newsome, J. M., Chen, Y., & Bercu, Z. L. (2025) · npj Biomedical Innovations. · doi:10.1038/s44385-025-00049-3 · Cited by 2
Olivares, A., Schuhler‐Husson, C., Zine, Y., & Drouin, S. (2026) · Healthcare Technology Letters · doi:10.1049/htl2.70040 · Cited by 2
Chaerunnisa, A., Madhuvu, A., Najm, D., Fooladi, E., & Victoria Team (2026) · International Wound Journal · doi:10.1111/iwj.70875 · Cited by 2
Improving the Competency of Nurses
Porte, P. J., Verweij, L. M., Collares, C. F., de Bruijne, M. C., van der Vleuten, C. P. M., & Wagner, C. (2020) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000395 · Cited by 2
“13,14 Although training could reduce the numbers of errors, it is resource intensive in an environment with an increasing number of medical devices, while less time is available for training.”
BackgroundGood, R. J., Diaz, E., Thomas, R., Wathen, B., & Carpenter, T. C. (2021) · The Journal of Vascular Access · doi:10.1177/11297298211024805 · Cited by 2
“Nurses first performed TA of the PIV which included (1) ability to flush, (2) ability to aspirate, (3) presence of swelling, (4) comparison to the contralateral side.”
MethodInfluentialThe Role of the Registered Nurse in the Use of Intraosseous Vascular Access Devices
Infusion Nurses Society and Emergency Nurses Association (2020) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000369 · Cited by 2
Murayama, R., Oyama, H., Abe‐Doi, M., Masamoto, Y., Kashiwabara, K., Tobe, H., Komiyama, C., Sanada, H., & Kurokawa, M. (2022) · Drug Discoveries & Therapeutics · doi:10.5582/ddt.2022.01034 · Cited by 2
Leroux, S., Deaner, T. S., Wasser, T., Huey, C., Carr, B., Howard, A., Anspach, C., Conner, J., & Sigal, A. P. (2023) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2023.02.011 · Cited by 2
Granger, K. L., Zersen, K. M., & Guieu, L.-V. (2024) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.23.12.0717 · Cited by 2
Using Implementation Science to Improve Short Peripheral Intravenous Catheter Outcomes
Hook, M. L., Woda, A., Bohr, K., Ford, C., & Singh, M. (2024) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000556 · Cited by 2
Extravasation and infiltration: under-recognised complications of intravenous therapy
Barton, A. (2024) · British Journal of Nursing · doi:10.12968/bjon.2024.33.sup7.s4 · Cited by 2
A Retrospective Look at Peripheral Intravenous Catheter (PIVC) Dwell Times in Pediatric PopulationCE
Wiseman, K. M., Berbert, L., DeGrazia, M., Pilcher, J., Forbes, P. W., & Reed, M. P. (2024) · Journal of the Association for Vascular Access · doi:10.2309/java-d-23-00025 · Cited by 2
Midclavicular tip positioning of midline catheters: a service improvement project
Phelps, J. (2025) · British Journal of Nursing · doi:10.12968/bjon.2022.0236 · Cited by 2
SCOPUS analysis of publications on nursing and phlebitis
Alkan, S., & AKYÜZ, H. Ö. (2023) · Demiroglu Science University Florence Nightingale Journal of Medicine · doi:10.5606/fng.btd.2023.23 · Cited by 3
Insertion and removal of PIVCs: Exploring best practices
Fowler, S. A., Penoyer, D., & Bourgault, A. M. (2018) · Nursing · doi:10.1097/01.nurse.0000534108.88895.e2 · Cited by 2
Dizbay, M., Özger, H. S., Bilgetekin, İ., Başyurt, R., Yurtal, Ö., Simsek, H., & Aksakal, F. N. B. (2019) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000336 · Cited by 2
Ultrasound-Detected Venous Changes Associated with Peripheral Intravenous Placement in Children
Goel, D., Smitthimedhin, A., Yadav, B., Vellody, R., Lele, M., Meagher, E., Yarmolenko, P., & Sharma, K. V. (2020) · Journal of the Association for Vascular Access · doi:10.2309/j.java.2020.001.003 · Cited by 2
Nam, A.-R.-N., Lee, D.-Y., & Jung, G.-H. (2019) · International Journal of Advanced Nursing Education and Research · doi:10.21742/ijaner.2019.4.3.05 · Cited by 2
“if the intravenous injection is not performed correctly, it is important to educate correct intravenous injection method to the nursing student [3] Recently, the medical dispute related to intravenous injection is being increased and the legal responsibility of the nurse is increased in the intravenous injection manag…”
BackgroundPeripheral venous access using devices over needles with and without extension: costs and outcomes
Lima, A. F. C., Saba, A., Filho, A. G. D. N., Couto, K. A., & Silva, L. O. E. (2020) · Revista Brasileira de Enfermagem · doi:10.1590/0034-7167-2018-0921 · Cited by 2
“Studies that analyzed the occurrences associated with PVA residence time indicated, as the most relevant, the presence of phlebitis(1,10,14-15,18,20,22), as well as pain(18), resulting in withdrawal early access, and accidental removal(1,20).”
Background
Metadata
- Authors
- Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E.
- Affiliations
- University of California, Los Angeles (US)
- ORCID
- Klausner, Jeffrey D.
- Venue
- Journal of Infusion Nursing
- Published
- 2015-05
- Volume
- 38
- Issue
- 3
- Pages
- 189-203
- ISSN
- 1533-1458 (ISSN-L)
- OpenAlex
- W2038383229
- Semantic Scholar
- b809150968a99be946adbe1118551f554e8bc00b
- Cited by
- 445
- References
- 148
- Citations by year
- 2026: 32 · 2025: 43 · 2024: 50 · 2023: 45 · 2022: 71 · 2021: 63 · 2020: 49 · 2019: 32 · 2018: 33 · 2017: 19 · 2016: 7
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Infusion Nursing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- peripheral intravenous catheter insertion, catheter failure, catheter-related complications, failure mechanisms, patient safety
- MeSH terms
- Catheterization, Peripheral, Humans, Risk Factors, Time Factors, Treatment Failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.