Accepted but Unacceptable: Peripheral IV Catheter Failure
The DOI matches its Crossref record, with a small difference in title or year; 144 of the 148 references it cites were found in a registry or an index.
Abstract
Peripheral intravenous (IV) catheter insertion, the most common invasive hospital procedure performed worldwide, is associated with a variety of complications and an unacceptably high overall failure rate of 35% to 50% in even the best of hands. Catheter failure is costly to patients, caregivers, and the health care system. Although advances have been made, analysis of the mechanisms underlying the persistent high rate of peripheral IV failure reveals opportunities for improvement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although peripheral intravenous cannulation is the most common invasive hospital procedure performed worldwide, it is associated with an unacceptable high overall failure rate [5,6].”
Citations
Cites
Horan, T. C., Andrus, M., & Dudeck, M. A. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2008.03.002 · Cited by 6,626
Wisplinghoff, H., Bischoff, T., Tallent, S. M., Seifert, H., Wenzel, R. P., & Edmond, M. B. (2004) · Clinical Infectious Diseases · doi:10.1086/421946 · Cited by 4,496
An Intervention to Decrease Catheter-Related Bloodstream Infections in the ICU
Pronovost, P., Needham, D., Berenholtz, S., Sinopoli, D., Chu, H., Cosgrove, S., Sexton, B., Hyzy, R., Welsh, R., Roth, G., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061115 · Cited by 4,387
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Biofilms and Device-Associated Infections
Donlan, R. M. (2001) · Emerging Infectious Diseases · doi:10.3201/eid0702.010226 · Cited by 1,504
Hemodynamic parameters to guide fluid therapy
Marik, P. E., Monnet, X., & Teboul, J.-L. (2011) · Annals of Intensive Care · doi:10.1186/2110-5820-1-1 · Cited by 686
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W. J., Veeh, R., Shirtliff, M. E., Pasmore, M. E., Post, C., & Ehrlich, G. D. (2003) · Journal of Clinical Investigation · doi:10.1172/jci20365 · Cited by 649
How Staphylococcus aureus biofilms develop their characteristic structure
Periasamy, S., Joo, H.-S., Duong, A. C., Bach, T.-H. L., Tan, V. Y., Chatterjee, S. S., Cheung, G. Y. C., & Otto, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1115006109 · Cited by 640
The application of biofilm science to the study and control of chronic bacterial infections
Costerton, W., Veeh, R., Shirtliff, M., Pasmore, M., Post, C., & Ehrlich, G. (2003) · Journal of Clinical Investigation · doi:10.1172/jci200320365 · Cited by 630
Intravascular-catheter-related infections
Raad, I. (1998) · The Lancet · doi:10.1016/s0140-6736(97)10006-x · Cited by 627
Research works printed but not linked: 3
- Carlquist, 1981, Understanding the psychological needs of the patient on IV therapy: a stress-reducing approach., NITA, 4, 368
- Sarafzadeh, 2012, Evaluation of the severity of peripheral intravenous catheter related phlebitis during one year in an Iranian educational hospital, Kerman, Iran., Ann Biol Res, 3, 4741
- Ryder, 2005, Catheter related infections: its all about biofilm., Top Adv Pract Nurs e-J, 5, 1
Cited by
Use of Short Peripheral Intravenous Catheters: Characteristics, Management, and Outcomes Worldwide
Alexandrou, E., Ray‐Barruel, G., Carr, P. J., Frost, S. A., Inwood, S., Higgins, N., Lin, F., Alberto, L., Mermel, L., Rickard, C. M., et al. (2018) · Journal of Hospital Medicine · doi:10.12788/jhm.3039 · Cited by 430
“Africa 2813 (7) Asia 6428 (16) Australia / New Zealand 5855 (14) Europe 17223 (42) Middle East 529 (1) North America 5258 (13) South America 2384 (6) South Pacific 130 (1) Total 40620 (100)”
Marsh, N., Webster, J., Larsen, E., Cooke, M., Mihala, G., & Rickard, C. M. (2018) · Journal of Hospital Medicine · doi:10.12788/jhm.2867 · Cited by 267
“Hair unclipped at insertion 609 (39) 75 (12) 73 (12) 58 (10)”
Cooke, M., Ullman, A. J., Ray-Barruel, G., Wallis, M., Corley, A., & Rickard, C. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193436 · Cited by 233
Marsh, N., Webster, J., Ullman, A. J., Mihala, G., Cooke, M., Chopra, V., & Rickard, C. M. (2020) · Journal of Advanced Nursing · doi:10.1111/jan.14565 · Cited by 186
“It has also been suggested that variable phlebitis rates could reflect overlapping complications, such as occlusion, infiltration and early signs of infection (Helm et al., 2015).”
BackgroundCan nurses remain relevant in a technologically advanced future?
Pepito, J. A., & Locsin, R. (2019) · International Journal of Nursing Sciences · doi:10.1016/j.ijnss.2018.09.013 · Cited by 221
Pittiruti, M., Van Boxtel, T., Scoppettuolo, G., Carr, P., Konstantinou, E., Ortiz Miluy, G., Lamperti, M., Goossens, G. A., Simcock, L., Dupont, C., et al. (2023) · The Journal of Vascular Access · doi:10.1177/11297298211023274 · Cited by 188
“• • search was initially limited to 6 years (from Jan 2013 to Dec 2018), considering that many interesting studies had already been incorporated in some very good guidelines and evidence-based consensus documents published in 2013–2014;9,22 an update of the literature from Jan 2019 till Jan 2021 was added later, due t…”
BackgroundInfluentialPeripheral intravenous catheter failure: A secondary analysis of risks from 11,830 catheters
Marsh, N. M., Larsen, E. N., Takashima, M., Kleidon, T. M., Keogh, S. J., Ullman, A. J., Mihala, G., Chopra, V., & Rickard, C. M. (2021) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2021.104095 · Cited by 205
“( Helm et al., 2015 ; Royer, 2003 ) In addition, repeated peripheral intravenous catheter replacements can result in venous access depletion for patients, needle-phobia, hospital avoidance, and an increased likelihood of requiring a central venous access device, which is a more costly device with a…”
BackgroundResultInfluentialThe Midline Catheter: A Clinical Review
Adams, D. Z., Little, A., Vinsant, C., & Khandelwal, S. (2016) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2016.05.029 · Cited by 165
“children) and average dwell time of 44 h potentially requiring repeated cannulation for venous access during a prolonged hospitalization will quickly account for a single well-placed MC at the time of hospital admission (8,19,23).”
Keleekai, N. L., Schuster, C. A., Murray, C. L., King, M. A., Stahl, B. R., Labrozzi, L. J., Gallucci, S., LeClair, M. W., & Glover, K. R. (2016) · Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare · doi:10.1097/sih.0000000000000186 · Cited by 162
“After a PIVC has been placed, each removal due to complication and subsequent reinsertion progressively increases procedural costs and may lead to the use of more invasive vascular access devices.(7) The national financial burden for premature PIVC removal can be conservatively estimated at US $1.”
BackgroundInfluentialNeoh, K. G., Li, M., Kang, E.-T., Chiong, E., & Tambyah, P. A. (2017) · Journal of Materials Chemistry B · doi:10.1039/c6tb03280j · Cited by 169
Simin, D., Milutinović, D., Turkulov, V., & Brkic, S. V. (2019) · Journal of Clinical Nursing · doi:10.1111/jocn.14760 · Cited by 196
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020144 · Cited by 157
“Although peripheral intravenous cannulation is the most common invasive hospital procedure performed worldwide, it is associated with an unacceptable high overall failure rate [5,6].”
BackgroundPeripheral intravenous catheter infection and failure: A systematic review and meta-analysis
Marsh, N. M., Larsen, E. N., Ullman, A. J., Mihala, G., Cooke, M. L., Chopra, V., Ray‐Barruel, G., & Rickard, C. M. (2023) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2023.104673 · Cited by 160
Indications for peripheral, midline and central catheters: summary of the MAGIC recommendations
Moureau, N., & Chopra, V. (2016) · British Journal of Nursing · doi:10.12968/bjon.2016.25.8.s15 · Cited by 160
“Bedside nurses are more likely to request a PICC order after having difficulty establishing peripheral access rather than considering all options and appropriateness of central access (Chopra et al, 2015b; Helm et al, 2015; Woller et al, 2015).”
BackgroundVascular access specialist teams for device insertion and prevention of failure
Carr, P. J., Higgins, N. S., Cooke, M. L., Mihala, G., & Rickard, C. M. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011429.pub2 · Cited by 97
Ullman, A. J., Takashima, M., Kleidon, T. M., Ray‐Barruel, G., Alexandrou, E., & Rickard, C. M. (2019) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2019.09.023 · Cited by 119
Kleidon, T. M., Cattanach, P., Mihala, G., & Ullman, A. J. (2019) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.14384 · Cited by 83
Piper, R., Carr, P. J., Kelsey, L. J., Bulmer, A. C., Keogh, S. J., & Doyle, B. J. (2018) · Scientific Reports · doi:10.1038/s41598-018-21617-1 · Cited by 87
Best practice in the use of peripheral venous catheters: A scoping review and expert consensus
Zingg, W., Barton, A., Bitmead, J., Eggimann, P., Pujol, M., Simon, A., & Tatzel, J. (2023) · Infection Prevention in Practice · doi:10.1016/j.infpip.2023.100271 · Cited by 85
“Aseptic, non-touch technique should be used for insertion or reinsertion of PIVCs and during manipulation of catheter hubs, connectors, and stopcocks [1].”
BackgroundMethodInfluentialSteere, L., Ficara, C., Davis, M., & Moureau, N. (2019) · Journal of the Association for Vascular Access · doi:10.2309/j.java.2019.003.004 · Cited by 69
“8%.(1) To overcome the number one complication failure mode of PIVC occlusions, Hartford chose to incorporate the antireflux NC with proven documented results of 69% reduction in occlusions into the PIV5Rights Bundle.”
BackgroundMethodBlanco‐Mavillard, I., Rodríguez-Calero, M. Á., de Pedro‐Gómez, J. E., Parra-García, G., Fernández‐Fernández, I., & Castro‐Sánchez, E. (2019) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-019-0581-8 · Cited by 69
“Treating each episode of PIVC-BSI costs approximately US$45000 in The excess hospitalization costs associated to the treatment of each episode of PIVC-BSI amount to ~US$45000 [4, 6].”
BackgroundNickel, B. (2019) · Critical Care Nurse · doi:10.4037/ccn2019790 · Cited by 85
Guénézan, J., Marjanovic, N. S., Drugeon, B., Neill, R. O., Liuu, É., Roblot, F., Palazzo, P., Bironneau, V., Prevost, F., Paul, J. A., et al. (2021) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30738-6 · Cited by 68
“Minor skin reactions were uncommon (16 [2”
InfluentialRay‐Barruel, G., Cooke, M. L., Mitchell, M. L., Chopra, V., & Rickard, C. M. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-021290 · Cited by 69
Phlebitis Signs and Symptoms With Peripheral Intravenous Catheters: Incidence and Correlation Study
Mihala, G., Ray‐Barruel, G., Chopra, V., Webster, J., Wallis, M. C., Marsh, N. M., McGrail, M. R., & Rickard, C. M. (2018) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000288 · Cited by 73
Rodriguez-Calero, M. A., de Pedro-Gomez, J. E., Molero-Ballester, L. J., Fernandez-Fernandez, I., Matamalas-Massanet, C., Moreno-Mejias, L., Blanco-Mavillard, I., Moya-Suarez, A. B., Personat-Labrador, C., & Morales-Asencio, J. M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030799 · Cited by 60
“The quality of healthcare can be significantly improved by designing interventions to improve the efficacy of the first puncture, selecting the most appropriate catheter and reducing the pain of peripheral cannulation, thus minimising its adverse effects [10,15,33].”
BackgroundCorley, A., Ullman, A. J., Mihala, G., Ray‐Barruel, G., Alexandrou, E., & Rickard, C. M. (2019) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2019.103409 · Cited by 68
Risk factors for peripheral venous catheter failure: A prospective cohort study of 5345 patients
Chen, Y., Fan, X., Liu, M.-H., Wang, J., Yang, Y., & Su, Y. (2021) · The Journal of Vascular Access · doi:10.1177/11297298211015035 · Cited by 62
“914 The Journal of Vascular Access 23(6)”
Influentialon behalf of the AMOR-VENUS study group, Yasuda, H., Yamamoto, R., Hayashi, Y., Kotani, Y., Kishihara, Y., Kondo, N., Sekine, K., Shime, N., Morikane, K., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-020-00518-4 · Cited by 68
Peripheral intravenous catheter assessment: beyond phlebitis
Rickard, C. M., & Ray‐Barruel, G. (2017) · The Lancet Haematology · doi:10.1016/s2352-3026(17)30145-x · Cited by 61
Larsen, E. N., Marsh, N. M., O’Brien, C., Monteagle, E., Friese, C. R., & Rickard, C. M. (2020) · Supportive Care in Cancer · doi:10.1007/s00520-020-05643-2 · Cited by 73
“(suspected or laboratory-confirmed local or bloodstream infection [12]); occlusion (device will not infuse) [13]; infiltration (infusate leaking into the interstitial tissue; if with vesicant, this was considered extravasation) [14]; leakage (external); dislodgement (complete or partial removal from the vein); or phle…”
BackgroundLulie, M., Tadesse, A., Tsegaye, T., Yesuf, T., & Asres, M. S. (2021) · Thrombosis Journal · doi:10.1186/s12959-021-00301-x · Cited by 54
(2017) · Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz · doi:10.1007/s00103-016-2488-3 · Cited by 58
Vendramim, P., Avelar, A. F. M., Rickard, C. M., & Pedreira, M. D. L. G. (2020) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2019.103504 · Cited by 58
Improving outcomes of short peripheral vascular access in oncology and chemotherapy administration
Bertoglio, S., van Boxtel, T., Goossens, G. A., Dougherty, L., Furtwängler, R., Lennan, E., Pittiruti, M., Sjövall, K., & Stas, M. (2017) · The Journal of Vascular Access · doi:10.5301/jva.5000668 · Cited by 52
“• Insertion with use of tourniquet (18, 25) o A new single-use tourniquet should be used for each patient (1, 8, 27) • Local warmth application (28, 29) • Vein visualization tools (near-infrared light or ultrasound, as available) (30, 31).”
BackgroundMethodCost of vascular access devices in public hospitals in Queensland
Tuffaha, H., Marsh, N. M., Byrnes, J., Gavin, N., Webster, J., Cooke, M. L., & Rickard, C. M. (2018) · Australian Health Review · doi:10.1071/ah18102 · Cited by 49
Carr, P. J., Rippey, J. C. R., Cooke, M. L., Higgins, N. S., Trevenen, M., Foale, A., & Rickard, C. M. (2018) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2018.190 · Cited by 48
“This rate is only slightly lower than that of another study reporting 34% failure,(4) and it is in agreement with recent findings from multiple studies that PIF is a highly prevalent problem in healthcare.(3,5) It has been established that first-time insertion success rates are varied and need to improve.”
ResultYasuda, H., Rickard, C. M., Marsh, N. M., Yamamoto, R., Kotani, Y., Kishihara, Y., Kondo, N., Sekine, K., Shime, N., Morikane, K., et al. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01009-5 · Cited by 58
van Loon, F. H., Leggett, T., Bouwman, A. R., & Dierick-van Daele, A. T. (2020) · The Journal of Vascular Access · doi:10.1177/1129729820901653 · Cited by 46
“690 The Journal of Vascular Access 21(5)”
InfluentialReducing Risks and Improving Vascular Access Outcomes
Morrell, E. (2020) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000377 · Cited by 49
Hoskins, M. J., Nolan, B., Evans, K. L., & Phillips, B. (2023) · Medicine · doi:10.1097/md.0000000000033624 · Cited by 49
“[1] Despite this, PIVC failure rates remain unacceptably high, with a first-attempt failure rate of up to 30%.[7,8] Subsequently, these patients are often subject to delayed treatment, multiple puncture sites, increased progression to central venous access and resulting complications.”
BackgroundA Model of Phlebitis Associated with Peripheral Intravenous Catheters in Orthopedic Inpatients
Lee, S.-H., Kim, K., & Kim, J. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16183412 · Cited by 52
“Approximately 60% of hospitalized patients have at least one PIVC [2], and 80.”
BackgroundNursing students’ knowledge on the management of peripheral venous catheters at Wollega University
Etafa, W., Wakuma, B., Tsegaye, R., & Takele, T. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238881 · Cited by 42
Bell, J. A., & Spencer, T. R. (2020) · The Journal of Vascular Access · doi:10.1177/1129729820924554 · Cited by 41
Nurses' knowledge on routine care and maintenance of adult vascular access devices: A scoping review
Raynak, A., Paquet, F., Marchionni, C., Lok, V., Gauthier, M., & Frati, F. Y. E. (2020) · Journal of Clinical Nursing · doi:10.1111/jocn.15419 · Cited by 46
Berger, S. J., Winchester, K., Principe, R. B., & Culverwell, E. (2021) · Journal of Clinical Nursing · doi:10.1111/jocn.16051 · Cited by 47
UK Vessel Health and Preservation (VHP) Framework: a commentary on the updated VHP 2020
Hallam, C., Denton, A., Weston, V., Dunn, H., Jackson, T., Keeling, S., & Hill, S. (2021) · Journal of Infection Prevention · doi:10.1177/1757177420976806 · Cited by 40
“PIVCs have also been found to fail on delivery of courses of treatment in 35%–50% of cases resulting in negative cycle of re-cannulation (Gorski et al., 2016; Helm et al., 2015).”
BackgroundMarsh, N. M., Larsen, E. N., Genzel, J., Mihala, G., Ullman, A. J., Kleidon, T. M., Cadigan, S., & Rickard, C. M. (2018) · Trials · doi:10.1186/s13063-018-2985-9 · Cited by 40
The Prevalence and Associated Factors of Peripheral Intravenous Complications in a Thai Hospital
Kaphan, K., Auypornsakul, S., Somno, J., Wongwattananan, W., Jamsittikul, K., Baicha, W., Somsri, S., & Sawatrak, T. (2024) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000538 · Cited by 39
Vessel Health and Preservation: a model and clinical pathway for using vascular access devices
Moureau, N., & Carr, P. J. (2018) · British Journal of Nursing · doi:10.12968/bjon.2018.27.8.s28 · Cited by 45
“With reports of 31% of PIVs failing within the first 48 hours and 71% by 72 hours, optimal timing for the first phase of VHP assessment and selection is within the first 2 days of treatment (Helm et al, 2015).”
Does the Midline Peripheral Intravenous Catheter Have a Place in Critical Care?
Nickel, B. (2021) · Critical Care Nurse · doi:10.4037/ccn2021818 · Cited by 38
Prasad, R. O., Chew, T., Giri, J. R., & Hoerauf, K. H. (2022) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000460 · Cited by 37
“The 5 key domains of care, including (1) effectiveness of communication; (2) infection prevention measures; (3) pain management; (4) physical comfort; and (5) health care provider competence, were identified within a patient-centered care framework adapted from Picker’s 8 Principles of Patient Centered Care.”
BackgroundRosenthal, V., Belkebir, S., Zand, F., Afeef, M., Tanzi, V. L., Al-Abdely, H. M., El‐Kholy, A., AlKhawaja, S. A. A., Demiröz, A. P., Sayed, A. F., et al. (2020) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2020.03.012 · Cited by 41
Kleidon, T. M., Schults, J. A., Royle, R. H., Gibson, V., Ware, R. S., Andresen, E., Cattanach, P., Dean, A., Pitt, C., Ramstedt, M., et al. (2025) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/jamapediatrics.2024.5581 · Cited by 40
Blanco‐Mavillard, I., Castro‐Sánchez, E., Parra-García, G., Rodríguez-Calero, M. Á., Bennasar‐Veny, M., Fernández‐Fernández, I., Lorente-Neches, H., & de Pedro‐Gómez, J. E. (2022) · Antimicrobial Resistance and Infection Control · doi:10.1186/s13756-022-01144-5 · Cited by 34
“As seen in PIVC failure [5,6], healthcare organisations can incur unnecessary expenses and waste resources, fostering dissatisfaction among healthcare professionals and impoverishing the experience of care for patients [7,8], who are subject to increased hospital length of stays, morbidity and mortality [9].”
BackgroundEngström, Å. H., & Forsberg, A. (2018) · Journal of Clinical Nursing · doi:10.1111/jocn.14668 · Cited by 37
“Helm et al. (2015) investigated the rate of complications due to the removal of PVCs, which included phlebitis (15.4%), infiltration (23.9%), catheter occlusion (18.8%), catheter dislodgement (6.9”
BackgroundInfluentialSweeny, A. L., Archer‐Jones, A., Watkins, S., Johnson, L., Gunter, A., & Rickard, C. M. (2021) · Australasian Emergency Care · doi:10.1016/j.auec.2021.07.003 · Cited by 34
The state of vascular access teams: Results of a European survey
Rey, N. C., Pinelli, F., van Loon, F. H. J., Caguioa, J., Munoz-Mozas, G., Piriou, V., Teichgräber, U. K.-M., Lepelletier, D., & Mussa, B. (2021) · International Journal of Clinical Practice · doi:10.1111/ijcp.14849 · Cited by 33
Rickard, C. M., Larsen, E. N., Walker, R., Mihala, G., Byrnes, J., Saiyed, M., Cooke, M. L., Finucane, J., Carr, P. J., & Marsh, N. M. (2022) · Journal of Hospital Medicine · doi:10.1002/jhm.12995 · Cited by 33
“” 3,4 As a foreign body, PIVCs irritate the endothelium of the venous tunica intima, triggering thrombi.”
Wong, K., Cooper, A., Brown, J., Boyd, L., & Levinson, M. (2018) · Journal of Clinical Nursing · doi:10.1111/jocn.13961 · Cited by 32
Improving Vascular Access Outcomes and Enhancing Practice
Platt, V., & Osenkarski, S. (2018) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000304 · Cited by 36
“The purposes of this study were (1) to identify any areas of risk associated with PIVC insertion that could lead to needlestick injury, blood exposure, bloodstream infection, or other catheter-related complications; (2) to initiate process improvement projects and strategies to improve infusion practice and related la…”
MethodMoureau, N. (2018) · Journal of the Association for Vascular Access · doi:10.1016/j.java.2018.07.002 · Cited by 33
“The average cost of an uncomplicated PIV insertion in the United States is estimated at $28 to $35.(2) Based on US usage volume, mean number of device attempts (2.”
BackgroundInfluentialKleidon, T. M., Rickard, C. M., Gibson, V., Mihala, G., Schults, J. A., Xu, H. G., Bauer, M. J., Marsh, N. M., Larsen, E. N., Cattanach, P., et al. (2020) · Journal of Tissue Viability · doi:10.1016/j.jtv.2020.03.006 · Cited by 35
“Traditionally these have additional attachment points and adhesive base pads to anchor the PIVC, however, can be bulky, and reduce dressing adhesion [7].”
BackgroundA Nurse-Led Ultrasound-Enhanced Vascular Access Preservation Program
Reeves, T., Morrison, D., & Altmiller, G. (2017) · AJN American Journal of Nursing · doi:10.1097/01.naj.0000527490.24610.51 · Cited by 32
Yılmaz, D. U., & Sarı, D. (2021) · Nurse Education Today · doi:10.1016/j.nedt.2021.104924 · Cited by 42
Corley, A., Marsh, N. M., Ullman, A. J., & Rickard, C. M. (2022) · Journal of Clinical Nursing · doi:10.1111/jocn.16237 · Cited by 35
“PIVC failure results in costs to both patients and healthcare institutions (Helm et al., 2015); for patients, pain and anxiety from reinsertions; and for healthcare institutions, financial burden of human and material resources to replace failed PIVCs, in addition to costs of treating PIVC complica…”
BackgroundGlover, K. R., Stahl, B. R., Murray, C., LeClair, M. W., Gallucci, S., King, M. A., Labrozzi, L. J., Schuster, C., & Keleekai-Brapoh, N. (2017) · The Journal of Continuing Education in Nursing · doi:10.3928/00220124-20170816-05 · Cited by 30
Blanco‐Mavillard, I., Parra-García, G., Fernández‐Fernández, I., Rodríguez-Calero, M. Á., Personat-Labrador, C., & Castro‐Sánchez, E. (2020) · PLoS ONE · doi:10.1371/journal.pone.0240086 · Cited by 32
“…these catheters are prematurely removed during intravenous therapy due to PIVC failure [4], which is defined as the unplanned removal of the device due to mechanical complications (i.e., phlebitis, occlusion, infiltration) or infection before the completion of scheduled intravenous therapy [5, 6].”
Ultrasound-guided versus traditional method for peripheral venous access: an umbrella review
Berlanga‐Macías, C., Díez‐Fernández, A., Martínez‐Hortelano, J. A., Sequí‐Domínguez, I., Saz‐Lara, A., Pozuelo‐Carrascosa, D. P., & Martínez‐Vizcaíno, V. (2022) · BMC Nursing · doi:10.1186/s12912-022-01077-9 · Cited by 32
“Considering that pediatrics have particular conditions and a higher failure rate, as it happens in adults, [4, 31] US is presented as a valid alternative in both populations.”
BackgroundShort Peripheral Catheter Quality and Economics: The Intravenous Quotient
Jones, R. K. (2018) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000303 · Cited by 28
Thomas, C., Cabilan, C. J., & Johnston, A. N. B. (2020) · Australasian Emergency Care · doi:10.1016/j.auec.2020.02.001 · Cited by 29
Standard Versus Long Peripheral Catheters for Multiday IV Therapy: A Randomized Controlled Trial
Qin, K. R., Ensor, N., Barnes, R., Englin, A., Nataraja, R. M., & Pacilli, M. (2021) · PEDIATRICS · doi:10.1542/peds.2020-000877 · Cited by 28
A prospective sonographic evaluation of peripheral intravenous catheter associated thrombophlebitis
Mielke, N., Johnson, S., Karabon, P., & Bahl, A. (2021) · The Journal of Vascular Access · doi:10.1177/11297298211009019 · Cited by 31
Marsh, N. M., Larsen, E. N., O’Brien, C., Ware, R. S., Kleidon, T. M., Groom, P., Hewer, B., Alexandrou, E., Flynn, J. M., Woollett, K., et al. (2022) · International Journal of Nursing Practice · doi:10.1111/ijn.13110 · Cited by 28
Fernández‐Fernández, I., Parra-García, G., Blanco‐Mavillard, I., Carr, P. J., Santos‐Costa, P., & Rodríguez-Calero, M. Á. (2024) · BMJ Open · doi:10.1136/bmjopen-2023-082631 · Cited by 36
Standards of care for peripheral intravenous catheters: evidence-based expert consensus
Thompson, J., Steinheiser, M. M., Hotchkiss, J. B., Davis, J., DeVries, M., Frate, K., Helm, R. E., Jungkans, C. W., Kakani, S. R., Lau, S., et al. (2024) · British Journal of Nursing · doi:10.12968/bjon.2024.0422 · Cited by 27
Self-citationTissue adhesive for vascular access devices: who, what, where and when?
Corley, A., Marsh, N. M., Ullman, A. J., & Rickard, C. M. (2017) · British Journal of Nursing · doi:10.12968/bjon.2017.26.19.s4 · Cited by 27
“Additionally, re-siting failed VADs can be distressing and increases risk to the patient (Helm et al, 2015).”
BackgroundAddressing the Silence: a Need for Peripheral Intravenous Education in North America
Hunter, M. R., Vandenhouten, C., Raynak, A., Owens, A. K., & Thompson, J. (2018) · Journal of the Association for Vascular Access · doi:10.1016/j.java.2018.06.001 · Cited by 30
Chróinín, D. N., Ray‐Barruel, G., Carr, P. J., Frost, S. A., Rickard, C. M., Mifflin, N., McManus, C., & Alexandrou, E. (2022) · Australian Journal on Ageing · doi:10.1111/ajag.13068 · Cited by 28
“Emergency Department 271 (28) 281 (24) 552 (25)”
van Rens, M. F. P. T., Spencer, T. R., Hugill, K., Francia, A. L. V., van Loon, F. H. J., & Bayoumi, M. A. A. (2023) · The Journal of Vascular Access · doi:10.1177/11297298231154629 · Cited by 27
Borgonovo, F., Quici, M., Gidaro, A., Giustivi, D., Cattaneo, D., Gervasoni, C., Calloni, M. V., Martini, E., Cava, L. L., Antinori, S., et al. (2023) · Antibiotics · doi:10.3390/antibiotics12081338 · Cited by 31
“It is very important to note that contact between subcutaneous tissues and the drug does not occur only in the event of a massive leakage due to mechanical events (such as catheter dislocation) but also due to altered permeability of the venous walls due to an inflammatory process affecting them [8].”
BackgroundCastillo, M. I. A., Larsen, E. N., Cooke, M. L., Marsh, N. M., Wallis, M. C., Finucane, J., Brown, P., Mihala, G., Carr, P. J., Byrnes, J., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-019916 · Cited by 28
“In addition, covariates associated with catheter failure including patient variables and catheter variables will be evaluated. hypothesis The use of an integrated PIVC will reduce the incidence of PIVC failure compared with the use of a non-integrated PIVC.”
InfluentialEffectiveness of transparent film dressing for peripheral intravenous catheter
Atay, S., & Kurt, F. Y. (2020) · The Journal of Vascular Access · doi:10.1177/1129729820927238 · Cited by 26
Mussa, B., Pinelli, F., Rey, N. C., Caguioa, J., van Loon, F. H. J., Munoz-Mozas, G., Teichgräber, U. K.-M., & Lepelletier, D. (2021) · Hospital Practice · doi:10.1080/21548331.2021.1909897 · Cited by 26
“safety [5], but this can be overcome with a dedicated VAT [1,14].”
BackgroundInfluentialIntravenous Infiltration Risk by Catheter Dwell Time Among Hospitalized Children
Jeong, I. S., Jeon, G. R., Lee, M. S., Shin, B. J., Kim, Y., Park, S. M., & Hyun, S. (2016) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2016.08.008 · Cited by 26
A hand-held robotic device for peripheral intravenous catheterization
Cheng, Z., Davies, B. L., Caldwell, D. G., Barresi, G., Xu, Q., & Mattos, L. S. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917737328 · Cited by 27
Pare, J. R., Pollock, S. E., Liu, J., Leo, M. M., & Nelson, K. P. (2018) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2018.11.021 · Cited by 25
Cyanoacrylate tissue adhesive: a new tool for the vascular access toolbox
Nicholson, J., & Hill, J. G. (2019) · British Journal of Nursing · doi:10.12968/bjon.2019.28.19.s22 · Cited by 25
Mechanism of pulsatile flushing technique for saline injection via a peripheral intravenous catheter
Zhu, L., Liu, H., Wang, R., Yu, Y., Zheng, F., & Yin, J. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.105103 · Cited by 28
Hiding in Plain Sight: Peripheral Intravenous Catheter Infections
Nickel, B. (2020) · Critical Care Nurse · doi:10.4037/ccn2020439 · Cited by 27
The Use of Visualization Technology for the Insertion of Peripheral Intravenous Catheters
Pitts, S., & Ostroff, M. D. (2019) · Journal of the Association for Vascular Access · doi:10.2309/j.java.2019.003.007 · Cited by 24
Baye, N. D., Teshome, A. A., Ayenew, A. A., Jemere, T., Mulu, A. T., Abebe, E. C., Tiruneh, G. A., Ayele, T. M., Muche, Z. T., Teklemariam, A. B., et al. (2023) · BMC Nursing · doi:10.1186/s12912-022-01164-x · Cited by 24
“Occlusion is also a common cause of premature loss of catheter function [12].”
BackgroundParreira, P., Serambeque, B., Santos‐Costa, P., Mónico, L. D. S. M., Oliveira, V., Sousa, L. B., Gama, F., Bernardes, R. A., Adriano, D., Marques, I. A., et al. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16183301 · Cited by 26
Karaoğlan, N., Sarı, H. Y., & Devrim, İ. (2022) · British Journal of Nursing · doi:10.12968/bjon.2022.31.8.s14 · Cited by 23
Martínez, J. A. C., Suárez-Mier, M. B., Ortega, M. D. C. M., Rodríguez, R. C., Renes, C. V., & Pisabarro, C. D. R. (2023) · The Journal of Vascular Access · doi:10.1177/11297298231189963 · Cited by 23
Kim, J. W., Jarzembak, J. M., & Kim, K. (2023) · Sensors · doi:10.3390/s23156697 · Cited by 24
Bahl, A., Gibson, S. M., Jankowski, D., & Chen, N. (2021) · The Journal of Vascular Access · doi:10.1177/11297298211024037 · Cited by 23
Steere, L., Rousseau, M. R., & Durland, L. (2018) · Journal of the Association for Vascular Access · doi:10.1016/j.java.2018.01.002 · Cited by 22
Canning, M. L., & Grannell, L. (2020) · Australian Prescriber · doi:10.18773/austprescr.2020.051 · Cited by 22
Moureau, N. (2024) · Expert Review of Medical Devices · doi:10.1080/17434440.2024.2324885 · Cited by 24
Metadata
- Authors
- Helm, R. E., Klausner, J. D., Klemperer, J. D., Flint, L. M., & Huang, E.
- Affiliations
- University of California, Los Angeles (US)
- ORCID
- Klausner, Jeffrey D.
- Venue
- Journal of Infusion Nursing
- Published
- 2015-05
- Volume
- 38
- Issue
- 3
- Pages
- 189-203
- ISSN
- 1533-1458 (ISSN-L)
- OpenAlex
- W2038383229
- Semantic Scholar
- b809150968a99be946adbe1118551f554e8bc00b
- Cited by
- 445
- References
- 148
- Citations by year
- 2026: 32 · 2025: 43 · 2024: 50 · 2023: 45 · 2022: 71 · 2021: 63 · 2020: 49 · 2019: 32 · 2018: 33 · 2017: 19 · 2016: 7
- FWCI
- 4.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Infusion Nursing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Keywords
- peripheral intravenous catheter insertion, catheter failure, catheter-related complications, failure mechanisms, patient safety
- MeSH terms
- Catheterization, Peripheral, Humans, Risk Factors, Time Factors, Treatment Failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.