CoChat

The Performance of Cerebrospinal Fluid Treponemal-Specific Antibody Tests in Neurosyphilis: A Systematic Review

Harding, Alexander S., Ghanem, Khalil G. · 2012 · Sexually Transmitted Diseases

The DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.

Abstract

Background No single laboratory test is both sensitive and specific to diagnose neurosyphilis. Several major clinical guidelines suggest that negative cerebrospinal fluid (CSF) treponemal-specific antibody tests rule out the diagnosis of neurosyphilis. Our aim was to systematically review the literature and describe the performance of treponemal-specific CSF antibody tests when diagnosing neurosyphilis. Methods Two reviewers independently assessed studies published in electronic databases, trial registries, and bibliographies for content and quality. Entry criteria included the assessment of treponemal-specific CSF tests currently used in clinical practice, and the use of standard criteria for both diagnosis and exclusion of neurosyphilis. The primary outcomes were sensitivity, specificity, and negative predictive values of treponemal-specific CSF antibody tests. Results Of 141 unique citations, 18 studies were included in the systematic review. Due to significant heterogeneity among studies, we were unable to generate pooled summary statistics. Seven different treponemal-specific tests were assessed. Of those, 13 studies evaluated the CSF FTA-ABS (fluorescent treponemal antibody-absorbed) and 9 evaluated the CSF fluorescent treponemal antibody. The performance estimates of these tests were highly variable and depended on the choice of negative and positive controls. No single test had perfect sensitivity, thus the negative predictive value was dependant on the specificity of…

Overview

Integrity signals

Registry

Crossref · 10.1097/olq.0b013e31824c0e62

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 2

  1. Workowski, 2010, Centers for Disease Control and Prevention (CDC). Sexual Transmitted Disease Treatment Guidelines, 2010., MMWR Recomm Rep, 59, 1
  2. Jadad, 1996, Carroll D, et al.., Assessing the quality of reports of randomized clinical trials: Is blinding necessary Control Clin Trials, 17, 1

Cited by

See all 139

Metadata

Authors
Harding, A. S., & Ghanem, K. G.
Affiliations
Johns Hopkins University (US)
Corresponding author
Ghanem, Khalil G.
Venue
Sexually Transmitted Diseases
Published
2012-04
Volume
39
Issue
4
Pages
291-297
ISSN
0148-5717 (ISSN-L)
OpenAlex
W1965604613
Cited by
125
References
25
Citations by year
2026: 6 · 2025: 7 · 2024: 8 · 2023: 6 · 2022: 14 · 2021: 9 · 2020: 9 · 2019: 8 · 2018: 9 · 2017: 7 · 2016: 9 · 2015: 11 · 2014: 13 · 2013: 8 · 2012: 1
FWCI
7.08
Type
journal article
Language
en
Open access
closed
Locations
  • Sexually Transmitted Diseases (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Syphilis Diagnosis and Treatment
  • Life Sciences › Immunology and Microbiology › Microbiology › Bacterial Infections and Vaccines
  • Life Sciences › Immunology and Microbiology › Parasitology › Vector-borne infectious diseases
Keywords
neurosyphilis, cerebrospinal fluid, FTA-ABS test, sensitivity and specificity, negative predictive value, VDRL test, HIV coinfection, syphilis diagnosis
MeSH terms
Antibodies, Bacterial, Female, Humans, Male, Neurosyphilis, Predictive Value of Tests, Syphilis Serodiagnosis, Treponema pallidum, Fluorescent Treponemal Antibody-Absorption Test

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.