Power Profiles of Multifocal Contact Lenses and Their Interpretation
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Purpose: Many contact lens (CL) manufacturers produce simultaneous‐image lenses in which power varies either smoothly or discontinuously with zonal radius. We present in vitro measurements of some recent CLs and discuss how power profiles might be approximated in terms of nominal distance corrections, near additions, and on‐eye visual performance. Methods: Fully hydrated soft, simultaneous‐image CLs from four manufacturers (Air Optix AQUA, Alcon; PureVision multifocal, Bausch & Lomb; Acuvue OASYS for Presbyopia, Vistakon; Biofinity multifocal‐ “D” design, Cooper Vision) were measured with a Phase focus Lens Profiler (Phase Focus Ltd., Sheffield, UK) in a wet cell and powers were corrected to powers in air. All lenses had zero labeled power for distance. Results: Sagittal power profiles revealed that the “low” add PureVision and Air Optix lenses exhibit smooth (parabolic) profiles, corresponding to negative spherical aberration. The “mid” and “high” add PureVision and Air Optix lenses have bi‐aspheric designs, leading to different rates of power change for the central and peripheral portions. All OASYS lenses display a series of concentric zones, separated by abrupt discontinuities; individual profiles can be constrained between two parabolically decreasing curves, each giving a valid description of the power changes over alternate annular zones. Biofinity lenses have constant power over the central circular region of radius 1.5 mm, followed by an annular zone where the power increases approximately linearly, the gradient increasing with the add power, and finally an outer zone showing a slow, linear increase in power with a gradient being almost independent of the add power. Conclusions: The variation in power across the simultaneous‐image lenses produces enhanced depth of focus. The through‐focus nature of the image, which influences the “best focus” (distance correction) and the reading addition, will vary with several factors, including lens centration, the wearer's pupil diameter, and ocular aberrations, particularly spherical aberration; visual performance with some designs may show greater sensitivity to these factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“accuracy in these measurements is key to realizing the maximum benefits of FFLs [75].”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [75]
Citations
Cites
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
(1994) · PubMed · Cited by 688
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Age-related changes in monochromatic wave aberrations of the human eye.
McLellan, J. S., Marcos, S. C., & Burns, S. A. (2001) · PubMed · Cited by 293
Superresolution imaging via ptychography
Maiden, A. M., Humphry, M. J., Zhang, F., & Rodenburg, J. M. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.28.000604 · Cited by 256
Effect of Focus on the Visual Response to a Sinusoidally Modulated Spatial Stimulus*
Green, D. G., & Campbell, F. W. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001154 · Cited by 182
The effect of ocular aberrations on steady-state errors of accommodative response
Plainis, S., Ginis, H. S., & Pallikaris, A. (2005) · Journal of Vision · doi:10.1167/5.5.7 · Cited by 181
Self-citationOptical ptychography: a practical implementation with useful resolution
Maiden, A. M., Rodenburg, J. M., & Humphry, M. J. (2010) · Optics Letters · doi:10.1364/ol.35.002585 · Cited by 180
Applegate, R. A., Donnelly, W. J., Marsack, J. D., Koenig, D. E., & Pesudovs, K. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.000578 · Cited by 163
Research works printed but not linked: 6
- Plainis S, 1996, Methods for verifying the power of soft contact lenses: a review, Optician, 212, 42
- Vogt A, 2011, Using power profiles to evaluate aspheric lenses, Contact Lens Spectrum, 26, 43
- Plainis S, 2011, Commenting on “Using power profiles to evaluate aspheric lenses”, Contact Lens Spectrum, 26, 15
- Atchison DA, 2012, Presbyopia: Origins, Effects and Treatment, 21
- Born M, 1993, Principles of Optics
- Charman WN, 1988, Retinal images with centred aspheric varifocal contact lenses, Int Contact Lens Clin, 15, 87
Cited by
Developments in the correction of presbyopia I: spectacle and contact lenses
Charman, W. N. (2014) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12091 · Cited by 174
“Any on-eye multifocal effect would be expected to arise primarily from the ‘step’ segments, rather than the parabolic power change.(120) Exact effects will, however, depend upon the individual eye, since there is a substantial spread in individual values of ocular spherical aberration at any age.”
Self-citationPower profiles of single vision and multifocal soft contact lenses
Wagner, S., Conrad, F., Bakaraju, R. C., Fedtke, C., Ehrmann, K., & Holden, B. A. (2014) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2014.07.008 · Cited by 104
Accommodation and Phoria in Children Wearing Multifocal Contact Lenses
Gong, C. R., Troilo, D., & Richdale, K. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001044 · Cited by 92
“50D lens suggests that the children would be experiencing the majority of the plus power and asphericity (spherical aberration) in the lens with pupil sizes as small as about 4 mm.(39) Accommodative amplitude and facility were taken binocularly to assess ‘‘real-world’’ testing conditions.”
InfluentialSoft multifocal simultaneous image contact lenses: a review
Pérez‐prados, R., Pinero, D. P., Pérez-Cambrodí, R. J., & Madrid‐Costa, D. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12488 · Cited by 90
“Techniques for measuring the power distribution are based on Hartmann–Shack or interference systems and they allow the clinician to discuss how the distance and near corrections provided by these lenses vary with the pupil diameter(61) and with its centration.(65) Power profiles give considerable Soft multifocal conta…”
BackgroundMethodInfluentialBifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control
Remón, L., Pérez‐Merino, P., Macedo-de-Araújo, R. J., Amorim‐de‐Sousa, A., & González‐Méijome, J. M. (2020) · Journal of Ophthalmology · doi:10.1155/2020/8067657 · Cited by 89
“In Figure 2, we illustrate the power maps (left), the proportion of the total pupil area covered by the distance and near correction as a function of the pupil diameter (center), and the through-focus Visual Strehl (right) for four different soft multifocal contact lenses (A: Acuvue Oasys for presbyopia, medium additi…”
BackgroundInfluentialRetardation of Myopia Progression by Multifocal Soft Contact Lenses
Zhu, Q., Liu, Y., Tighe, S. P., Zhu, Y., Su, X., Lu, F., & Hu, M. (2019) · International Journal of Medical Sciences · doi:10.7150/ijms.30118 · Cited by 70
“(3) Pupil size: Pupil size has a significant effect on MFSCLs performance [72].”
BackgroundMadrid‐Costa, D., Ruiz‐Alcocer, J., García‐Lázaro, S., Ferrer‐Blasco, T., & Montés‐Micó, R. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.03.008 · Cited by 67
Power Profiles of Commercial Multifocal Soft Contact Lenses
Kim, E., Bakaraju, R. C., & Ehrmann, K. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000000998 · Cited by 65
“This design aims to achieve pupil independent performance by alternatively including distance and near power zones with increasing pupil diameter.(9) With presbyopia being a progressive condition in which the eye gradually loses its ability to focus up close, contact lens FIGURE 8 (cont.”
BackgroundMethodInfluentialBCLA CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye
Morgan, P. B., Murphy, P. J., Gifford, K., Gifford, P., Golebiowski, B., Johnson, L., Makrynioti, D., Moezzi, A., Moody, K. J., Navascues‐Cornago, M., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.006 · Cited by 62
Randomized Crossover Trial of Silicone Hydrogel Presbyopic Contact Lenses
Sivardeen, A., Laughton, D. S., & Wolffsohn, J. S. (2015) · Optometry and Vision Science · doi:10.1097/opx.0000000000000780 · Cited by 47
“between the Biofinity multifocal lenses and the monovision lenses, which may be caused by the larger stable area of constant power over the central region of the Biofinity center-distance lenses compared with the other multifocal lens designs.(36) Under mesopic conditions, the high- and low-contrast visual acuity atta…”
BackgroundPauné, J., Thivent, S., Armengol, J., Junyent, L. Q. I., Faria‐Ribeiro, M. Á., & González‐Méijome, J. M. (2016) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000222 · Cited by 46
Cardona, G., & López, S. G. (2015) · Journal of Optometry · doi:10.1016/j.optom.2015.06.005 · Cited by 46
Correction of presbyopia: old problems with old (and new) solutions
Kollbaum, P. S., & Bradley, A. (2020) · Clinical and Experimental Optometry · doi:10.1111/cxo.12987 · Cited by 45
“Designs that incorporate two powers in alternating annular zones often also include significant regions of the lens in which there is a gradual power change with increasing radial distance.(98,99) For exam-”
BackgroundBCLA CLEAR – Contact lens optics
Richdale, K., Cox, I., Kollbaum, P. S., Bullimore, M. A., Bakaraju, R. C., Gifford, P., Plainis, S., McKenney, C., Newman, S., Tomiyama, E. S., et al. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.02.005 · Cited by 46
Self-citationShort-term visual performance of soft multifocal contact lenses for presbyopia
Sha, J., Bakaraju, R. C., Tilia, D., Chung, J., Delaney, S., Munro, A., Ehrmann, K., Thomas, V., & Holden, B. A. (2016) · Arquivos Brasileiros de Oftalmologia · doi:10.5935/0004-2749.20160023 · Cited by 44
“AOP is a center-distance design featuring distance and near concentric rings that are designed to provide consistent vision regardless of pupil size and also incorporating negative spherical aberration((18)).”
BackgroundAltoaimi, B. H., Kollbaum, P. S., Meyer, D., & Bradley, A. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12438 · Cited by 44
BCLA CLEAR Presbyopia: Management with contact lenses and spectacles
Morgan, P. B., Efron, N., PAPAS, E. B., Barnett, M., Carnt, N. A., Dutta, D., Hepworth, A., Little, J., Nagra, M., Pult, H., et al. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102158 · Cited by 44
“Each contact lens may be constructed as a centre-near or centre-distance design [37,49,51,97;132,133].”
BackgroundFedtke, C., Ehrmann, K., & Bakaraju, R. C. (2019) · Journal of Optometry · doi:10.1016/j.optom.2018.11.002 · Cited by 43
“Besides the general lens design differences known for single vision, concentric bifocal or center-distance and center-near multifocal lenses, there are distinctive differences between the individual contact lens types from each manufacturer and some power profiles of the same contact lens type (brand) vary as a functi…”
BackgroundAccommodative Behavior of Young Eyes Wearing Multifocal Contact Lenses
Altoaimi, B. H., Almutairi, M. S., Kollbaum, P. S., & Bradley, A. (2018) · Optometry and Vision Science · doi:10.1097/opx.0000000000001214 · Cited by 41
Visual Acuity and Over‐refraction in Myopic Children Fitted with Soft Multifocal Contact Lenses
Schulle, K. L., Berntsen, D. A., Sinnott, L. T., Bickle, K. M., Tićak, A., Pierce, G. E., Jones‐Jordan, L. A., Mutti, D. O., Walline, J. J., & for The Bifocal Lenses in Nearsighted Kids (BLINK) Study Group (2018) · Optometry and Vision Science · doi:10.1097/opx.0000000000001207 · Cited by 40
Short‐Term Visual Performance of Novel Extended Depth‐of‐Focus Contact Lenses
Tilia, D., Bakaraju, R. C., Chung, J., Sha, J., Delaney, S., Munro, A., Thomas, V., Ehrmann, K., & Holden, B. A. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000000806 · Cited by 39
“Most multifocals are center-distance or center-near designs(8) with a monotonic power profile.(12) The exception is ACUVUE OASYS for Presbyopia (AOP, senofilcon A; Johnson & Johnson Vision Care, FL USA), which is a non-monotonic, zonal-refractive aspheric design multifocal.”
BackgroundMethodInfluentialImpact of Spherical Aberration Terms on Multifocal Contact Lens Performance
Fedtke, C., Sha, J., Thomas, V., Ehrmann, K., & Bakaraju, R. C. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000001017 · Cited by 38
“Two recent studies by Wagner et al.11 and Plainis et al.12 measured power profiles using the SHSOphthalmic (Optocraft) and the Phase Focus Lens Profiler (Phase Focus Ltd., UK), respectively.”
MethodResultInfluentialHastings, G. D., Marsack, J. D., Thibos, L. N., & Applegate, R. A. (2018) · Journal of the Optical Society of America A · doi:10.1364/josaa.35.000732 · Cited by 38
“which has, for example, been used in studies of traditional [21] and wavefront-guided [22,23] contact lens corrections, reading speed [24], intra-ocular lenses (IOLs) [25], and the optical properties of the cornea [26].”
MethodPeripheral Refraction and Aberration Profiles with Multifocal Lenses
Fedtke, C., Ehrmann, K., Thomas, V., & Bakaraju, R. C. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001112 · Cited by 37
Phase calibration target for quantitative phase imaging with ptychography
Godden, T. M., Muñiz-Piniella, A., Claverley, J. D., Yacoot, A., & Humphry, M. J. (2016) · Optics Express · doi:10.1364/oe.24.007679 · Cited by 36
Tilia, D., Munro, A., Chung, J., Sha, J., Delaney, S., Kho, D., Thomas, V., Ehrmann, K., & Bakaraju, R. C. (2016) · Journal of Optometry · doi:10.1016/j.optom.2016.04.003 · Cited by 35
“Center-near lenses have a central maximum positive power and negative primary spherical aberration C(4,0), resulting in a monotonic refractive power profile(10) which achieves distance correction in the periphery of the optical zone of the lens.(10,11) Unlike non-monotonic zonal-refractive multifocals,(10) center-near…”
BackgroundBifocal & Atropine in Myopia Study: Baseline Data and Methods
Huang, J., Mutti, D. O., Jones‐Jordan, L. A., & Walline, J. J. (2019) · Optometry and Vision Science · doi:10.1097/opx.0000000000001378 · Cited by 35
Sivardeen, A., Laughton, D. S., & Wolffsohn, J. S. (2016) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2016.05.002 · Cited by 33
“In addition to routine contact lens fit data (including pupil size), ocular aberrations may also influence presbyopic contact lens performance and acceptance [5-7].”
BackgroundKim, E., Bakaraju, R. C., & Ehrmann, K. (2015) · Journal of Optometry · doi:10.1016/j.optom.2015.10.005 · Cited by 31
“Plainis et al.6 published power profiles of multifocal contact lenses using this instrument and interpreted how the optical designs relate to visual performance.”
BackgroundMethodInfluentialIMI—Instrumentation for Myopia Management
Jones, D., Chow, A. H. Y., Fadel, D., González‐Méijome, J. M., Grzybowski, A. E., Kollbaum, P. S., Loughman, J., & Wolffsohn, J. S. (2025) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.66.9.7 · Cited by 28
“96,97,100,135 For example, Figure 4 row 1 shows sample refractive power maps over an 8 mm aperture of a single vision lens (column 1) and two-sample zonal lens designs.”
Power profiles of centre–distance multifocal soft contact lenses
Nti, A. N., Ritchey, E. R., & Berntsen, D. A. (2020) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12770 · Cited by 28
“This is a common problem with instruments that use mathematical algorithms to calculate optical power and has previously been observed and discussed in other contact lens metrology studies.(16,17) The instrument used in this study has already been validated to provide reliable power measurements outside of this centra…”
Plainis, S., Ktistakis, E., & Tsilimbaris, M. K. (2023) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2023.101853 · Cited by 27
Self-citationPinero, D. P., Carracedo, G., Ruiz-Fortes, P., & Pérez-Cambrodí, R. J. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12299 · Cited by 27
BCLA CLEAR Presbyopia: Evaluation and diagnosis
Wolffsohn, J. S., Berkow, D., Chan, K. Y., Chaurasiya, S. K., Fadel, D., Haddad, M. F., Imane, T., Jones, L., Sheppard, A. L., Vianya-Estopà, M., et al. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102156 · Cited by 27
Repeatability of in vitro power profile measurements for multifocal contact lenses
Domínguez‐Vicent, A., Marín‐Franch, I., Esteve-Taboada, J. J., Madrid‐Costa, D., & Montés‐Micó, R. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.01.013 · Cited by 27
“[8], measured the power profile of several multifocal contact lenses with a lens profiler based on ptychographic imaging.”
BackgroundPredicting Short-Term Subjective Vision Performance of Contact Lenses Used in Myopia Control
Diec, J., Tilia, D., Thomas, V., & Bakaraju, R. C. (2017) · Eye & Contact Lens Science & Clinical Practice · doi:10.1097/icl.0000000000000460 · Cited by 27
Advances and challenges of soft contact lens design for myopia control
Li, Q., & Fang, F. (2019) · Applied Optics · doi:10.1364/ao.58.001639 · Cited by 27
Gifford, K., Schmid, K. L., Collins, J. M., Maher, C. B., Makan, R., Nguyen, E., Parmenter, G. B., Rolls, B. M., Zhang, X. S., & Atchison, D. A. (2021) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12892 · Cited by 25
“37 The NaturalVue lens is indicated to have effectively no central spherical optical zone, with relative plus power increasing almost immediately from the lens centre.”
Self-citationQuantitative optical inspection of contact lenses immersed in wet cell using swept source OCT
Karnowski, K., Grulkowski, I., Mohan, N., Cox, I., & Wojtkowski, M. (2014) · Optics Letters · doi:10.1364/ol.39.004727 · Cited by 25
Coldrick, B. J., Richards, C., Sugden, K., Wolffsohn, J. S., & Drew, T. E. (2016) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2016.01.002 · Cited by 25
“low coherence interferometry [2], ptychography [3]).”
Papadatou, E., Águila‐Carrasco, A. J. D., Esteve-Taboada, J. J., Madrid‐Costa, D., & Cerviño, A. (2017) · International Journal of Ophthalmology · doi:10.18240/ijo.2017.01.17 · Cited by 22
Artefact-free topography based scleral-asymmetry
Abass, A., Lopes, B. T., Eliasy, A., Salomão, M. Q., Wu, R., White, L., Jones, S., Clamp, J., Ambrósio, R., & Elsheikh, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0219789 · Cited by 22
Analysis of the power profile of a new soft contact lens for myopia progression
Ruiz‐Alcocer, J. (2016) · Journal of Optometry · doi:10.1016/j.optom.2016.08.003 · Cited by 21
“This is interesting for creating myopic defocus, however, more refractive annular rings may induce more visual disturbances by the increase in the scattering into the eye.(6) Despite their differences, both lenses should provide constant myopic defocus blur effect for children at both distance and near, since children…”
BackgroundReducing starbursts in highly aberrated eyes with pupil miosis
Xu, R., Kollbaum, P. S., Thibos, L. N., López‐Gil, N., & Bradley, A. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12420 · Cited by 21
Visual performance with multifocal lenses in young adults and presbyopes
Vedhakrishnan, S., Viñas, M., Benedí‐García, C., Casado, P., & Marcos, S. C. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263659 · Cited by 21
“, the power profile of the lenses, near add [33, 34] and the patient’s optical profile, including pupil size [34, 35] and optical aberrations).”
BackgroundThe Effect of Light Level and Small Pupils on Presbyopic Reading Performance
Xu, R., Gil, D., Dibas, M. I., Hare, W. A., & Bradley, A. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.16-20008 · Cited by 20
“The power profile of the Air Optix multifocal was documented in Figure 4 and the Table of Plainis et al.(51)”
MethodFitting success for three multifocal designs: Multicentre randomised trial
Díaz, E. N., Villa-Collar, C. C., Narváez-Peña, M., & Martín, J. L. R. (2017) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2017.12.012 · Cited by 19
Calvo-Sanz, J. A., & Sánchez‐Tena, M. Á. (2018) · Journal of Optometry · doi:10.1016/j.optom.2018.10.003 · Cited by 19
Rio, D., Woog, K., & Legras, R. (2016) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12300 · Cited by 19
“More recently, Plainis et al. 14 measured a mean pupil diameter of 5.6 mm in subjects between 40 and 50 years old, 5.2 mm at around 55, and 4.8 mm around 65 years of age at 50 cd.m (cid:1) 2 .”
InfluentialMultifocal contact lenses: A bibliometric study
Alvarez-Peregrina, C. C., Sánchez‐Tena, M. Á., Martin, M., Villa-Collar, C. C., & Povedano-Montero, F. J. (2020) · Journal of Optometry · doi:10.1016/j.optom.2020.07.007 · Cited by 19
Schmid, K. L., Gifford, K., & Atchison, D. A. (2022) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2022.101588 · Cited by 17
Self-citationFaria‐Ribeiro, M. Á., Amorim‐de‐Sousa, A., & González‐Méijome, J. M. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12443 · Cited by 17
“No spherical aberration was added to the resulting wavefront; therefore, we assume that the average positive spherical aberration of the eye(24,25) couples with the negative spherical aberration(26) regularly implemented in contemporary contact lenses.(27) The resulting sagittal power profiles of the dual-focus lenses…”
Roadmap on advances in visual and physiological optics
Gómez-Correa, J. E., Vohnsen, B., Pierscionek, B. K., Chávez-Cerda, S., Kling, S., Rozema, J. J., Applegate, R. A., Scarcelli, G., Randleman, J. B., Goncharov, A. V., et al. (2025) · Journal of Optics · doi:10.1088/2040-8986/ae1bb8 · Cited by 15
Self-citationOptimal orientation for angularly segmented multifocal corrections
Gracia, P. D., & Hartwig, A. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12402 · Cited by 15
“PureVision2 Multi-Focal high add or Biofinity multifocal from CooperVision, Pleasanton, California).(1) During the last years several studies have shown the superiority of optical properties of multifocal designs with angular divisions compared to the optical designs with radial Correction added on 04 October 2017, af…”
Multifocal contact lens vision simulated with a clinical binocular simulator
Barcala, X., Viñas, M., Ruiz, S., Hidalgo, F., Nankivil, D., Karkkainen, T., Gambra, E., Dorronsoro, C., & Marcos, S. C. (2022) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2022.101716 · Cited by 15
“In general, the interaction of the ocular optics and pupil size with the lens design, as well as the subjects neural processing, all play a role on the perceived visual quality and achieved visual performance with M− CLs [10].”
BackgroundFedtke, C., Ehrmann, K., Thomas, V., & Bakaraju, R. C. (2016) · Clinical Optometry · doi:10.2147/opto.s96712 · Cited by 16
“28 Lastly, differences in visual performance between MFCLs can be attributed to differences in their power profiles, 11,29 pupil size, 30,31 and contact lens centration.”
Ocular Straylight with Different Multifocal Contact Lenses
Łabuz, G., López‐Gil, N., Berg, T., & Vargas-Martín, F. (2016) · Optometry and Vision Science · doi:10.1097/opx.0000000000001043 · Cited by 15
“The power profile of Oasys with the same addition resulted in several abrupt changes,(36,37) and this could be considered as a potential source of light scattering.(29) However, the results of the current study rather contradict this hypothesis, as the lowest straylight was found in the Oasys group.”
ResultLight distortion of soft multifocal contact lenses with different pupil size and shape
Monsálvez-Romín, D., González‐Méijome, J. M., Esteve-Taboada, J. J., García‐Lázaro, S., & Cerviño, A. (2019) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2019.11.014 · Cited by 14
Martínez‐Alberquilla, I., García‐Montero, M., Ruiz‐Alcocer, J., Crooke, A., & Madrid‐Costa, D. (2020) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2020.11.004 · Cited by 14
Multifocal contact lenses: towards customisation?
Faria‐Ribeiro, M. Á., & González‐Méijome, J. M. (2019) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12597 · Cited by 14
“Incorporating negative primary SA in the CL base power profile is intended to compensate for the effects of the usually positive SA of the eye, and is common in commercial designs.(11) However, most manufacturers offer only one choice of power profile for each add power.”
Small-pupil versus multifocal strategies for expanding depth of focus of presbyopic eyes
Xu, R., Wang, H., Jaskulski, M., Kollbaum, P. S., & Bradley, A. (2019) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2019.01.015 · Cited by 14
On‐eye centration of soft contact lenses
Walther, G., Meyer, D., Richards, J., Rickert, M. E., & Kollbaum, P. S. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13278 · Cited by 13
The effect of peripheral defocus on axial growth and modulation of refractive error in hyperopes
Beasley, I. G., Davies, L. N., & Logan, N. S. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12951 · Cited by 13
Gomez-Pedrero, J. A., Albarrán‐Diego, C., García‐Montero, M., Garzón, N., & Fernández, V. G. (2023) · Applied Sciences · doi:10.3390/app13179882 · Cited by 13
Centration and Decentration of Contact Lenses during Peripheral Gaze
El-Nimri, N. W., & Walline, J. J. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001127 · Cited by 13
Non-surgical treatment options for presbyopia
Charman, W. N. (2018) · Expert Review of Ophthalmology · doi:10.1080/17469899.2018.1506330 · Cited by 13
Self-citationPower profiles in multifocal contact lenses with variable multifocal zone
Monsálvez-Romín, D., Domínguez‐Vicent, A., García‐Lázaro, S., Esteve-Taboada, J. J., & Cerviño, A. (2017) · Clinical and Experimental Optometry · doi:10.1111/cxo.12575 · Cited by 12
Lorente‐Velázquez, A., García‐Montero, M., GOMEZ-SANZ, F., Rico‐del‐Viejo, L., Hernández‐Verdejo, J. L., & Madrid‐Costa, D. (2019) · International Journal of Ophthalmology · doi:10.18240/ijo.2019.04.19 · Cited by 12
Relative Peripheral Myopia Induced by Fractal Contact Lenses
Rodríguez‐Vallejo, M., Montagud-Martínez, D., Monsoriu, J. A., Ferrando, V., & Furlan, W. D. (2018) · Current Eye Research · doi:10.1080/02713683.2018.1507043 · Cited by 11
Fourier tools for the evaluation of refractive multifocal designs
Gracia, P. D. (2023) · Scientific Reports · doi:10.1038/s41598-023-50172-7 · Cited by 10
Dang, R. M., Ehrmann, K., Jalbert, I., Hui, A., & Kang, P. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13345 · Cited by 8
“32 The different methods employed emphasises the highly variable nature of MFCL power profiles and lack of standardised add power notation.”
Tićak, A., Walline, J. J., Berntsen, D. A., Mutti, D. O., Jones‐Jordan, L. A., Cardenas, L., Day, E., Dougherty, B. E., & The BLINK Study Group (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13216 · Cited by 8
Esteban-Ibañez, E., Montagud-Martínez, D., Sawides, L., Zaytouny, A., de Castro, A., Sisó-Fuertes, I., Barcala, X., Pinero, D. P., Furlan, W. D., Dorronsoro, C., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-59178-1 · Cited by 8
“To the best of our knowledge, three commercial devices have been used to measure MCL power profiles in different studies: NIMO TR-1504 (Lambda X, Belgium) 11 , SHSOphthalmic (Optocraft, Germany) 12 and Phase Focus Lens Profiler (Phase Focus Ltd, UK) 13 .”
MethodSimulation of commercial vs theoretically optimised contact lenses for presbyopia
Legras, R., & Rio, D. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12382 · Cited by 8
“Four of them came from real multifocal contact lens measurements.(21) The authors measured fully hydrated soft, simultaneousimage contact lenses from four manufacturers with a Phase Focus Lens Profiler in a wet cell.”
Accommodative Behavior of Eyes Wearing Aspheric Single Vision Contact Lenses
Altoaimi, B. H., Almutairi, M. S., Kollbaum, P. S., & Bradley, A. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001121 · Cited by 8
Gaze and behavioural metrics in the refractive correction of presbyopia
Smith, S. L., Maldonado‐Codina, C., Morgan, P. B., & Read, M. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13310 · Cited by 7
“7 The wearer receives mixed visual inputs of distance and near images, which usually require a period of visual adaptation.”
Functional Design Analysis of Two Current Extended-Depth-of-Focus Intraocular Lenses
Mendroch, D., Oberheide, U., & Altmeyer, S. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.8.33 · Cited by 7
“36 Del Águila-Carrasco et al. 37 went as far as presenting a method to estimate wavefront errors from a measured power map.”
MethodLee, A.-Y., Kim, J.-M., & Lee, K.-J. (2015) · Journal of Korean Ophthalmic Optics Society · doi:10.14479/jkoos.2015.20.2.117 · Cited by 7
Zeri, F., Vizio, A. D., Lucia, S., Berchicci, M., Bianco, V., Pitzalis, S., Tavazzi, S., Naroo, S. A., & Russo, F. D. (2024) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2024.102137 · Cited by 7
Zeri, F., Vizio, A. D., Guida, M., Rotondi, A., Tavazzi, S., & Naroo, S. A. (2020) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2020.02.008 · Cited by 7
“This can modify the spherical aberration of the ocular system either in a positive direction, in case of centre-distance design MCL, or in negative direction in case of centre-near design MCL (Plainis, 2013; Perez-Prados et al, 2017).”
BackgroundTalens‐Estarelles, C., Valle, A. G.-D., & García‐Lázaro, S. (2021) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2021.03.007 · Cited by 7
Developments in Contact Lens Imaging: New Applications of Optical Coherence Tomography
Stachura, J., Seredyka-Burduk, M., Piotrowiak-Słupska, I., Kaszuba-Modrzejewska, M., Rzeszewska-Zamiara, J., & Kałużny, B. J. (2019) · Applied Sciences · doi:10.3390/app9132580 · Cited by 6
Optical methods for the management of progressive myopia
Myagkov, A. V., & Myagkov, D. A. (2023) · The EYE GLAZ · doi:10.33791/2222-4408-2023-2-151-162 · Cited by 6
Optical quality of rotationally symmetrical contact lenses derived from their power profiles
Águila‐Carrasco, A. J. D., Monsálvez-Romín, D., & Papadatou, E. (2017) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2017.05.005 · Cited by 6
Kamiya, K., Fujimura, F., Ando, W., Iijima, K., & Shoji, N. (2020) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2020.03.013 · Cited by 6
Seo, C.-Y., & Ryu, G. (2018) · The Korean Journal of Vision Science · doi:10.17337/jmbi.2018.20.1.69 · Cited by 5
The effect of multifocal contact lenses on the dynamic accommodation step response
Mahmood, M., Day, M., Seidel, D., & Cameron, L. A. (2024) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13275 · Cited by 4
“71 Undoubtedly, the pupil diameter of the subjects will have an influence on the aberrations experienced though distance-centre MFCLs. 68,69 It will affect how much dioptric power of the progressive and near areas of the MFCL are utilised when subjects observed the target, which in turn will affect…”
BackgroundInfluentialMeyler, J., & Ruston, D. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-7020-8427-0.00022-2 · Cited by 4
On the power profiles of contact lenses measured with NIMO TR1504
Rodríguez‐Vallejo, M., Montagud-Martínez, D., Monsoriu, J. A., & Furlan, W. D. (2017) · Journal of Optometry · doi:10.1016/j.optom.2016.10.002 · Cited by 4
“Soft bifocal contact lenses (CL) have been found to slow the progression of myopia in children.(2) It was suggested that such lenses reduce the rate of myopia progression in children because of the relative myopic defocus that they induce in the peripheral retina and/or because they reduce accommodative lags.”
Chen, Y., Yang, B., Kou, J., & Liu, L. (2024) · PubMed Central · doi:10.12182/20240960507 · Cited by 3
Kamiya, K., Iijima, K., Hiraoka, T., Takada, K., Mori, Y., & Miyata, K. (2021) · Ophthalmology and Therapy · doi:10.1007/s40123-021-00414-6 · Cited by 3
Ehrmann, K. (2023) · Elsevier eBooks · doi:10.1016/b978-0-7020-8427-0.00007-6 · Cited by 3
Ehrmann, K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-7020-6660-3.00007-1 · Cited by 3
Power profiles of 3‐addition multifocal soft contact lens system
Jaisankar, D., & Back, A. (2025) · Optometry and Vision Science · doi:10.1097/opx.0000000000002274 · Cited by 2
Methods for creation of diffractive intraocular lenses
Gornostay, A. V. (2017) · International Conference on Information Technology and Nanotechnology (ITNT) · doi:10.18287/1613-0073-2017-1900-20-27 · Cited by 2
“Investigation of multifocal lenses, and, particularly, IOLs is object of interest in many countries from the 80th to our days [3-11].”
BackgroundPhotoacoustic imaging methodology for the optical characterization of contact lenses
Tserevelakis, G. J., Tsagkaraki, M., Tsilimbaris, M. K., Plainis, S., & Zacharakis, G. (2017) · Optics Letters · doi:10.1364/ol.42.004111 · Cited by 2
Self-citationHiraoka, T., Kiuchi, G., Hiraoka, R., Kotsuka, J., Kinoshita, Y., & Oshika, T. (2021) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-021-00862-4 · Cited by 2
“In brief, they have a non-monotonic, aperiodic, non-diffractive, non-aspheric, refractive power profile across the optic zone diameter, and increase the depth of focus by deliberate manipulation of multiple modes of spherical aberration terms (described in a patent application [17–19] This EDF design contrasts with th…”
BackgroundSoft Multifocal Contact Lenses for Myopia Control in Children
Korsan, J. M. (2015) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Accommodative response in various design soft contact lens wearers
Kassaliete, E., Gordeja, A., Panke, K., Petrova, A., & Krūmiņa, G. (2021) · Proceedings of the Estonian Academy of Sciences · doi:10.3176/proc.2021.4s.04 · Cited by 1
Visual Performance and Satisfaction of Extended Depth of Focus Contact Lenses in Presbyopic Subjects
Kamiya, K., Tokuda, S., Kaida, T., Higashi, S., Hashiguchi, M., Kanaya, E., & Miyata, K. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14030818 · Cited by 1
“The EDOF is achieved by the deliberate manipulation of multiple modes of spherical aberration terms [12,13].”
Metadata
- Authors
- Plainis, S., Atchison, D. A., & Charman, W. N.
- Affiliations
- University of Crete (GR)
- Corresponding author
- Plainis, Sotiris
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-10
- Volume
- 90
- Issue
- 10
- Pages
- 1066-1077
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2110300024
- Cited by
- 115
- References
- 48
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 10 · 2023: 7 · 2022: 3 · 2021: 8 · 2020: 6 · 2019: 11 · 2018: 9 · 2017: 19 · 2016: 16 · 2015: 9 · 2014: 2 · 2013: 1
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Optometry and Vision Science (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- multifocal contact lenses, power profile, spherical aberration, depth of focus, near addition, distance correction, lens centration, pupil size, ocular aberrations
- MeSH terms
- Contact Lenses, Equipment Design, Humans, Presbyopia, Optics and Photonics, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.