Power Profiles of Multifocal Contact Lenses and Their Interpretation
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Purpose: Many contact lens (CL) manufacturers produce simultaneous‐image lenses in which power varies either smoothly or discontinuously with zonal radius. We present in vitro measurements of some recent CLs and discuss how power profiles might be approximated in terms of nominal distance corrections, near additions, and on‐eye visual performance. Methods: Fully hydrated soft, simultaneous‐image CLs from four manufacturers (Air Optix AQUA, Alcon; PureVision multifocal, Bausch & Lomb; Acuvue OASYS for Presbyopia, Vistakon; Biofinity multifocal‐ “D” design, Cooper Vision) were measured with a Phase focus Lens Profiler (Phase Focus Ltd., Sheffield, UK) in a wet cell and powers were corrected to powers in air. All lenses had zero labeled power for distance. Results: Sagittal power profiles revealed that the “low” add PureVision and Air Optix lenses exhibit smooth (parabolic) profiles, corresponding to negative spherical aberration. The “mid” and “high” add PureVision and Air Optix lenses have bi‐aspheric designs, leading to different rates of power change for the central and peripheral portions. All OASYS lenses display a series of concentric zones, separated by abrupt discontinuities; individual profiles can be constrained between two parabolically decreasing curves, each giving a valid description of the power changes over alternate annular zones. Biofinity lenses have constant power over the central circular region of radius 1.5 mm, followed by an annular zone where the power increases approximately linearly, the gradient increasing with the add power, and finally an outer zone showing a slow, linear increase in power with a gradient being almost independent of the add power. Conclusions: The variation in power across the simultaneous‐image lenses produces enhanced depth of focus. The through‐focus nature of the image, which influences the “best focus” (distance correction) and the reading addition, will vary with several factors, including lens centration, the wearer's pupil diameter, and ocular aberrations, particularly spherical aberration; visual performance with some designs may show greater sensitivity to these factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“accuracy in these measurements is key to realizing the maximum benefits of FFLs [75].”
From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [75]
Citations
Cites
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
(1994) · PubMed · Cited by 688
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Age-related changes in monochromatic wave aberrations of the human eye.
McLellan, J. S., Marcos, S. C., & Burns, S. A. (2001) · PubMed · Cited by 293
Superresolution imaging via ptychography
Maiden, A. M., Humphry, M. J., Zhang, F., & Rodenburg, J. M. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.28.000604 · Cited by 256
Effect of Focus on the Visual Response to a Sinusoidally Modulated Spatial Stimulus*
Green, D. G., & Campbell, F. W. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001154 · Cited by 182
The effect of ocular aberrations on steady-state errors of accommodative response
Plainis, S., Ginis, H. S., & Pallikaris, A. (2005) · Journal of Vision · doi:10.1167/5.5.7 · Cited by 181
Self-citationOptical ptychography: a practical implementation with useful resolution
Maiden, A. M., Rodenburg, J. M., & Humphry, M. J. (2010) · Optics Letters · doi:10.1364/ol.35.002585 · Cited by 180
Applegate, R. A., Donnelly, W. J., Marsack, J. D., Koenig, D. E., & Pesudovs, K. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.000578 · Cited by 163
Contact lens correction of presbyopia
Bennett, E. S. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00242.x · Cited by 142
Rocha, K. M., Vabre, L., Chateau, N., & Krueger, R. R. (2009) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2009.05.059 · Cited by 141 · cited 1×
“Higher DOF estimates were found by Rocha and his colleagues.(48) However, in all studies, Power Profiles of Multifocal Contact LensesVPlainis et al.”
BackgroundDepth of focus and visual acuity with primary and secondary spherical aberration
Yi, F., Iskander, D. R., & Collins, M. J. (2011) · Vision Research · doi:10.1016/j.visres.2011.05.006 · Cited by 140 · cited 2×
“It is the increase in DOF over what would be achieved with a single-vision lens that constitutes the ‘‘add’’ effect.(27) A further complication is the coupling of the aberrations of the eye, in particular its spherical aberration, with the power characteristics of the lens worn.”
BackgroundMethodSpherical aberration and the information content of optical images
Black, G., & Linfoot, E. H. (1957) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1957.0059 · Cited by 106 · cited 1×
“Experimental and theoretical studies suggest that, in the presence of spherical aberration of this form, conventional measurements of subjective refraction correspond closely to the paraxial focus, largely because this is optimal for objects whose spatial frequency spectrum is dominated by high frequencies, such as sm…”
BackgroundBenard, Y., Lopez-Gil, N., & Legras, R. (2011) · Vision Research · doi:10.1016/j.visres.2011.10.003 · Cited by 101
Koomen, M. J., Scolnik, R., & Tousey, R. (1951) · Journal of the Optical Society of America · doi:10.1364/josa.41.000080 · Cited by 99 · cited 2×
“Experimental and theoretical studies suggest that, in the presence of spherical aberration of this form, conventional measurements of subjective refraction correspond closely to the paraxial focus, largely because this is optimal for objects whose spatial frequency spectrum is dominated by high frequencies, such as sm…”
BackgroundSimplified recording of soft contact lens fit
Wolffsohn, J. S., Hunt, O. A., & Basra, A. K. (2009) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2008.12.004 · Cited by 90
The effect of field of view size on steady-state pupil diameter
Stanley, P. A., & Davies, A. K. (1995) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.1995.9400019v.x · Cited by 90 · cited 1×
“, the product of the field luminance its subtended area) rather than simply on the luminance.(38,39) If, for example, we consider a sheet of white A4 paper in a well-lit office, its luminance will typically be around 100 cd/m(2) and, with a viewing distance of around 40 cm, its subtense will be a little in excess of 2…”
BackgroundBenard, Y., Lopez-Gil, N., & Legras, R. (2010) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2010.07.022 · Cited by 85
Analysis of Higher-Order Aberrations in a Large Clinical Population
Hartwig, A., & Atchison, D. A. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10610 · Cited by 84
Self-citationThe refraction of the eye in the relation to spherical aberration and pupil size.
Charman, W. N., Jennings, J. A. M., & Whitefoot, H. (1978) · PubMed · Cited by 77
Self-citationAberrations of emmetropic subjects at different ages
Atchison, D. A., & Markwell, E. L. (2008) · Vision Research · doi:10.1016/j.visres.2008.06.023 · Cited by 68
Self-citationAberrations associated with rigid contact lenses
Atchison, D. A. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.002267 · Cited by 66
Self-citationPlainis, S., Ntzilepis, G., Atchison, D. A., & Charman, W. N. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12004 · Cited by 63 · cited 1×
“Moreover, the wide range of SA values found for different individuals helps to explain why some wearers may find the lenses helpful while others do not.(6) In general, other monochromatic higher-order aberrations are likely to further blur the image and extend the DOF when either single-vision or more complex lenses a…”
BackgroundSelf-citationInherent Ocular Spherical Aberration and Multifocal Contact Lens Optical Performance
Bakaraju, R. C., Ehrmann, K., Ho, A., & PAPAS, E. B. (2010) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181fbad60 · Cited by 60
Visual performance with simultaneous vision multifocal contact lenses
Guillemot, A. L., García‐Lázaro, S., Ferrer‐Blasco, T., Pérez-Cambrodí, R. J., & Cerviño, A. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2011.00666.x · Cited by 59
Effect of photoexcitation of the two retinas on pupil size.
Doesschate, J. T., & Alpern, M. (1967) · Journal of Neurophysiology · doi:10.1152/jn.1967.30.3.562 · Cited by 59 · cited 1×
“5 mm, for the photopic range of luminance illustrated.(37) Moreover, for the same photopic range, the pupil diameter increases as the size of the stimulus field increases: for field diameters up to at least 25 degrees, the pupil diameter depends on the corneal flux density (i.”
BackgroundValidation of an Off‐Eye Contact Lens Shack‐Hartmann Wavefront Aberrometer
Kollbaum, P. S., Jansen, M. E., Thibos, L. N., & Bradley, A. (2008) · Optometry and Vision Science · doi:10.1097/opx.0b013e318185280e · Cited by 55
Charman, W. N., & Saunders, B. A. J. (1990) · Journal of The British Contact Lens Association · doi:10.1016/0141-7037(90)80012-q · Cited by 54
Self-citationCampbell, C. E. (2008) · Journal of Refractive Surgery · doi:10.3928/1081597x-20080301-15 · Cited by 54 · cited 1×
“Apart from the problem of avoiding lens distortion in the cell, major limitations often include modest lateral resolution and, with the Hartmann-Shack method, difficulties in relating the image spots to the appropriate lenslets, particularly when the lens power profile displays abrupt discontinuities.(15) A promising…”
MethodPlakitsi, A., & Charman, W. N. (1995) · Journal of The British Contact Lens Association · doi:10.1016/s0141-7037(95)80023-9 · Cited by 49
Self-citationDietze, H., & Cox, M. J. (2003) · Optometry and Vision Science · doi:10.1097/00006324-200302000-00008 · Cited by 49
Hickenbotham, A., Tiruveedhula, P. K., & Roorda, A. (2012) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2012.07.028 · Cited by 48 · cited 1×
“2 D for the conditions of the Hickenbotham et al study.(23) Thus, our estimates of the reading addition are about twice as high as the enhancements in DOF observed experimentally, suggesting that an effective reading add value of about b.”
MethodVisual performance of two simultaneous vision multifocal contact lenses
Madrid‐Costa, D., García‐Lázaro, S., Albarrán‐Diego, C., Ferrer‐Blasco, T., & Montés‐Micó, R. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12008 · Cited by 46 · cited 1×
“However, even for early presbyopes, having some reserves of accommodation and who require a moderate additions,(49) near visual acuity with such singleaspheric lenses does not appear to be sufficient.(50)”
BackgroundInfluence of field size on pupil diameter under photopic and mesopic light levels
Atchison, D. A., Girgenti, C. C., Campbell, G. M., Dodds, J. P., Byrnes, T. M., & Zele, A. J. (2011) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2011.00636.x · Cited by 45 · cited 1×
“, the product of the field luminance its subtended area) rather than simply on the luminance.(38,39) If, for example, we consider a sheet of white A4 paper in a well-lit office, its luminance will typically be around 100 cd/m(2) and, with a viewing distance of around 40 cm, its subtense will be a little in excess of 2…”
BackgroundSelf-citation“Bothersome blur”: A functional unit of blur perception
Ciuffreda, K. J., Selenow, A., Wang, B., Vasudevan, B. V., Zikos, G., & Ali, S. R. (2005) · Vision Research · doi:10.1016/j.visres.2005.10.004 · Cited by 44
Joannes, L. C., Hough, T., Hutsebaut, X., Dubois, X., Ligot, R., Saoul, B., Donink, P. V., & Coninck, K. D. (2009) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2009.11.001 · Cited by 44
Ocular aberrations and visual function with multifocal versus single vision soft contact lenses
Gifford, P., Cannon, T., Lee, C. Q. E., Lee, D., Lee, H. F., & Swarbrick, H. A. (2012) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2012.10.078 · Cited by 29
Total Illumination in a Diffraction Image Containing Spherical Aberration*
Barakat, R. G. (1961) · Journal of the Optical Society of America · doi:10.1364/josa.51.000152 · Cited by 29 · cited 1×
“This arises from the nature of the associated point-spread function, where at the paraxial focus there is a compact central core, favoring imaging at high spatial frequencies, surrounded by a larger blurred area which primarily reduces image contrast.(45,46) Because the lenses have negative spherical aberration (i.”
BackgroundAccommodative Functions with Multifocal Contact Lenses: A Pilot Study
Montés‐Micó, R., Madrid‐Costa, D., Radhakrishnan, H., Charman, W. N., & Ferrer‐Blasco, T. (2011) · Optometry and Vision Science · doi:10.1097/opx.0b013e31821c0ed8 · Cited by 28
Self-citationOn-Eye Power Characteristics of Soft Contact Lenses
Plainis, S., & Charman, W. N. (1998) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1998.tb04925.x · Cited by 25
Self-citationOptical Performance of Multifocal Soft Contact Lenses via a Single‐Pass Method
Bakaraju, R. C., Ehrmann, K., Falk, D., Ho, A., & PAPAS, E. B. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e318264f3e9 · Cited by 22
Plakitsi, A., & Charman, W. N. (1997) · Contact Lens and Anterior Eye · doi:10.1016/s1367-0484(97)80005-7 · Cited by 21 · cited 1×
“The through-focus nature of the image will change with the pupil diameter and, within the DOF, the ‘‘best focus’’ will vary with the spatial frequency spectrum of the object viewed.(4,13,25,26) However, it is clear that the ‘‘add’’ effect is not the same as the DOF because even a single-vision lens yields a non-zero D…”
BackgroundSelf-citationCorrection of presbyopia with contact lenses
Kallinikos, P. A., Santodomingo‐Rubido, J., Pallikaris, I. G., Plainis, S., & Charman, W. N. (2012) · Research Explorer (The University of Manchester) · Cited by 10
Self-citationDepth of focus of the human eye
Atchison, D. A. (2012) · QUT ePrints (Queensland University of Technology) · Cited by 6
Self-citationSpherical Aberration of a Hydrogel Contact Lens when Measured in a Wet Cell
Campbell, C. E. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e3181ae1eb0 · Cited by 5 · cited 1×
“With most of these, soft lenses are placed in a saline-filled wet cell, the derived powers being corrected to air values using a factor which allows for the different immersion index.(7,9) Apart from the problem of avoiding lens distortion in the cell, major limitations often include modest lateral resolution and, wit…”
MethodOptical Power Calculation for Contact Lens Wet Cells
Rw, Y., & Mandell, R. B. (1981) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1981.tb00155.x · Cited by 4
Presbyopia: Origins, Effects, and Treatment
Plainis, S., Charman, W. N., & Bullimore, M. A. (2012) · Cited by 3
Self-citation
Research works printed but not linked: 6
- Plainis S, 1996, Methods for verifying the power of soft contact lenses: a review, Optician, 212, 42
- Vogt A, 2011, Using power profiles to evaluate aspheric lenses, Contact Lens Spectrum, 26, 43
- Plainis S, 2011, Commenting on “Using power profiles to evaluate aspheric lenses”, Contact Lens Spectrum, 26, 15
- Atchison DA, 2012, Presbyopia: Origins, Effects and Treatment, 21
- Born M, 1993, Principles of Optics
- Charman WN, 1988, Retinal images with centred aspheric varifocal contact lenses, Int Contact Lens Clin, 15, 87
Cited by
Developments in the correction of presbyopia I: spectacle and contact lenses
Charman, W. N. (2014) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12091 · Cited by 174
“Any on-eye multifocal effect would be expected to arise primarily from the ‘step’ segments, rather than the parabolic power change.(120) Exact effects will, however, depend upon the individual eye, since there is a substantial spread in individual values of ocular spherical aberration at any age.”
Self-citationPower profiles of single vision and multifocal soft contact lenses
Wagner, S., Conrad, F., Bakaraju, R. C., Fedtke, C., Ehrmann, K., & Holden, B. A. (2014) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2014.07.008 · Cited by 104
Accommodation and Phoria in Children Wearing Multifocal Contact Lenses
Gong, C. R., Troilo, D., & Richdale, K. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001044 · Cited by 92
“50D lens suggests that the children would be experiencing the majority of the plus power and asphericity (spherical aberration) in the lens with pupil sizes as small as about 4 mm.(39) Accommodative amplitude and facility were taken binocularly to assess ‘‘real-world’’ testing conditions.”
InfluentialSoft multifocal simultaneous image contact lenses: a review
Pérez‐prados, R., Pinero, D. P., Pérez-Cambrodí, R. J., & Madrid‐Costa, D. (2016) · Clinical and Experimental Optometry · doi:10.1111/cxo.12488 · Cited by 90
“Techniques for measuring the power distribution are based on Hartmann–Shack or interference systems and they allow the clinician to discuss how the distance and near corrections provided by these lenses vary with the pupil diameter(61) and with its centration.(65) Power profiles give considerable Soft multifocal conta…”
BackgroundMethodInfluentialBifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control
Remón, L., Pérez‐Merino, P., Macedo-de-Araújo, R. J., Amorim‐de‐Sousa, A., & González‐Méijome, J. M. (2020) · Journal of Ophthalmology · doi:10.1155/2020/8067657 · Cited by 89
“In Figure 2, we illustrate the power maps (left), the proportion of the total pupil area covered by the distance and near correction as a function of the pupil diameter (center), and the through-focus Visual Strehl (right) for four different soft multifocal contact lenses (A: Acuvue Oasys for presbyopia, medium additi…”
BackgroundInfluential
Metadata
- Authors
- Plainis, S., Atchison, D. A., & Charman, W. N.
- Affiliations
- University of Crete (GR)
- Corresponding author
- Plainis, Sotiris
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2013-10
- Volume
- 90
- Issue
- 10
- Pages
- 1066-1077
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2110300024
- Cited by
- 115
- References
- 48
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 10 · 2023: 7 · 2022: 3 · 2021: 8 · 2020: 6 · 2019: 11 · 2018: 9 · 2017: 19 · 2016: 16 · 2015: 9 · 2014: 2 · 2013: 1
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Optometry and Vision Science (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- multifocal contact lenses, power profile, spherical aberration, depth of focus, near addition, distance correction, lens centration, pupil size, ocular aberrations
- MeSH terms
- Contact Lenses, Equipment Design, Humans, Presbyopia, Optics and Photonics, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.