Objectively Measured Light Exposure in Emmetropic and Myopic Adults
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Purpose: Light exposure has a close link with numerous aspects of human physiology including circadian rhythm, mood disorders, metabolism, and eye growth. Here, a lightweight wrist‐worn device was employed to continuously measure light exposure and activity across seasons and between refractive error groups to assess objectively measured differences and compare with subjectively reported data. Methods: Subjects, aged 21–65 years (n = 55), wore an actigraph device (Actiwatch Spectrum) continuously for 14 days to quantify light exposure, activity, and sleep. Subjects were classified as emmetropic (n = 18) or myopic (n = 37), and answered an activity questionnaire. Additionally, devices were calibrated against a lux meter and UV sensor for indoor and outdoor settings, and used to measure ambient illumination in various environmental conditions. Results: Subjects spent 1:52 ± 0:56 hours outside per day, as measured objectively. Subjectively reported measures overestimated objective measures by 0:25 ± 1:19 hours per day (range −1:49 to +4:29 hours, P <. 05). Subjects spent 1:04 hours more outdoors in summer and received an increased cumulative light dose compared to winter ( P <. 005). There were no significant differences in objective measurements of time outdoors between myopic and emmetropic subjects. Ambient illumination measures from the Actiwatch correlated with a lux meter for all locations tested ( R 2 = 0.99, P <. 001). Ambient illumination was highest in the summer at 176,497 ± 20,310 lux and lowest for indoor artificial light at 142 ± 150 lux. Conclusions: Subjects spent more time outdoors and received an increased light dose in summer, with no differences between refractive error groups in this adult population. Various environmental and seasonal measurements revealed significantly different available light in winter versus summer and indoors versus outdoors. Objective devices such as the Actiwatch can be valuable in studies where quantification of environmental factors is critical.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hattar, S., Liao, H.-W., Takao, M., Berson, D. M., & Yau, K.-W. (2002) · Science · doi:10.1126/science.1069609 · Cited by 2,734
Rosenthal, N. E. (1984) · Archives of General Psychiatry · doi:10.1001/archpsyc.1984.01790120076010 · Cited by 2,385
Chronically Alternating Light Cycles Increase Breast Cancer Risk in Mice
Van Dycke, K. C. G., Rodenburg, W., van Oostrom, C. T. M., van Kerkhof, L. W. M., Pennings, J. L. A., Roenneberg, T., van Steeg, H., & van der Horst, G. T. J. (2015) · Current Biology · doi:10.1016/j.cub.2015.06.012 · Cited by 170
Obayashi, K., Saeki, K., & Kurumatani, N. (2014) · Chronobiology International · doi:10.3109/07420528.2014.937491 · Cited by 110
Cited by
Circadian rhythms, refractive development, and myopia
Chakraborty, R., Ostrin, L. A., Nickla, D. L., Iuvone, P. M., Pardue, M. T., & Stone, R. A. (2018) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12453 · Cited by 235
“315,316 Sleep timing and melatonin rhythms, for instance, vary between time spent in a natural outdoor environment (e.g., camping) and in habitual indoors that include artificial light during both day and night.”
Self-citationIMI – Clinical Myopia Control Trials and Instrumentation Report
Wolffsohn, J. S., Kollbaum, P. S., Berntsen, D. A., Atchison, D. A., Benavente, A., Bradley, A., Buckhurst, H., Collins, M., Fujikado, T., Hiraoka, T., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25955 · Cited by 184
“…Microdaq.com Ltd, USA) 216,323,327 and wristwatch sensors that combine light sensors and measures of physical activity (such as Actiwatch devices; Philips Respironics, Andover, MA, USA) 325,328,329 and the recently developed FitSight fitness tracker (Singapore Eye Research Institute, Singapore).”
Attenuation of short wavelengths alters sleep and the ip RGC pupil response
Ostrin, L. A., Abbott, K. S., & Queener, H. M. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12385 · Cited by 69
Self-citationDev, M. K., Black, A. A., Cuda, D., & Wood, J. M. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.3.21 · Cited by 10
Metadata
- Authors
- Ostrin, L. A.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2017-02
- Volume
- 94
- Issue
- 2
- Pages
- 229-238
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2548207152
- Cited by
- 65
- References
- 4
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objectively Measured Light Exposure in Emmetropic and Myopic Adults. https://app.cochat.ai/papers/10.1097/opx.0000000000001013
- The paper
- Ostrin, L. A. (2017). Objectively Measured Light Exposure in Emmetropic and Myopic Adults. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000001013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.