CoChat

Personalized Progressive Addition Lenses: Correlation between Performance and Design

Forkel, Johanne, Reiniger, Jenny Lorén, Muschielok, Adam, Welk, Andrea, Seidemann, Anne, Baumbach, Peter · 2017 · Optometry and Vision Science
Cited by 21

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Supplemental digital content is available in the text. Purpose: A continuous set of personalized designs (design space) for progressive addition lenses (PALs) is investigated. The main goals are (1) to study how the subjects’ perception of a personalized design depends on its position in the design space and (2) to compare the performance of personalized PALs to a conventional PAL with a fixed design. Methods: In a double‐blind study, 51 subjects compared Rodenstock Impression FreeSign 3, which is a family of PALs with a continuously controllable personalized design, and Rodenstock Progressiv Life Free, which is a conventional PAL with a single fixed design. The positions and sizes of viewing zones and the softness of gradients of mean power and astigmatism of personalized lenses were customized to individual viewing preferences. These designs were represented as points in a design space comprising a continuum of PAL designs. Subjective ratings and experimental measurements were used to study viewing zone widths, blur gradient smoothness, amount of distortion, the feeling of safety during motion, and overall wearing comfort. Results: (1) Far viewing zone width (experiments and ratings), near viewing zone width (experiments), blur gradient smoothness, and the amount of distortion (ratings) were significantly dependent on the position of the personalized lens design in the design space. This was consistent with the structure of the design space. (2) 82% of the subjects chose personalized lenses as their favorite. Most subjects reported higher wearing comfort and tolerability with personalized lenses than with conventional lenses. Conclusions: The designs of the tested personalized lenses were perceived by the subjects as intended. This is a prerequisite to the successful customization of PALs to individual wearing preferences. Possible reasons for the preference of the tested personalized lenses are the optimization with respect to individual wearing conditions and the personalization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0000000000001016

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 21

Metadata

Authors
Forkel, J., Reiniger, J. L., Muschielok, A., Welk, A., Seidemann, A., & Baumbach, P.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2017-02
Volume
94
Issue
2
Pages
208-218
ISSN
  • 1040-5488 (ISSN-L)
  • 1538-9235
OpenAlex
W2559451311
Cited by
21
References
6
FWCI
0.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Personalized Progressive Addition Lenses: Correlation between Performance and Design. https://app.cochat.ai/papers/10.1097/opx.0000000000001016
The paper
Forkel, J., Reiniger, J. L., Muschielok, A., Welk, A., Seidemann, A., & Baumbach, P. (2017). Personalized Progressive Addition Lenses: Correlation between Performance and Design. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000001016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.