Scoring of Progressive Power Lenses by Means of User Power Maps
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: A progressive power lens (PPL) has a relatively complex power distribution, with regions for far, intermediate, and near vision, and also regions affected by aberrations, mainly astigmatism and defocus. Scoring techniques (Sheedy, Optom Vis Sci 2004;81:350-61) have been proposed to mark and classify PPLs according to their optical performance at each region. The objective of this study is to show that although scoring is useful to compare different lens designs, its outcome is highly dependent on the way power is defined and/or computed. METHODS: To demonstrate this, the progressive surfaces of many different current designs have been measured with a profiler. From these measurements and by means of exact ray tracing techniques, we obtain both the power maps that we would measure with a focimeter or a typical lens mapper and the power maps that the user perceives at the actual position of use. The scoring technique from Sheedy has then been applied to both types of maps. RESULTS: It is shown that the parameters that define the characteristics of a PPL when the power map is measured with a standard mapper are not significantly associated with the actual performance of the lens when it is fitted. In a similar way, it is shown that two lenses that have been optimized according to the same target power distribution may get completely different marks depending on the definition of power that has been used in the optimization process. We also propose a graphical method to easily grasp the overall PPL performance by simultaneously presenting four-dimensional information from the scoring technique. CONCLUSIONS: Although in general Sheedy's test is an important tool to compare different PPL designs, it cannot be used to compare those designs optimized for improving user power from classical front side designs when power has been measured for both types of designs with a standard focimeter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00245.x · Cited by 114
Progress in the spectacle correction of presbyopia. Part 2: modern progressive lens technologies
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00246.x · Cited by 87
Progressive addition lenses — matching the specific lens to patient needs
Sheedy, J. E. (2004) · Optometry - Journal of the American Optometric Association · doi:10.1016/s1529-1839(04)70021-4 · Cited by 82 · cited 2×
“Probably, one of the reasons for this lack of knowledge is that for many years, there was not a clear way to characterize the power distribution of PPLs. Sheedy et al.28,29 pioneered this effort with a thorough lens characterization that comprises the measurement of the width and the area of the far, intermediate, and…”
BackgroundAssessing visual performance with progressive addition lenses
SELENOW, A., BAUER, E. A., ALI, S. R., SPENCER, L. W., & CIUFFREDA, K. J. (2002) · Optometry and Vision Science · doi:10.1097/00006324-200208000-00012 · Cited by 76 · cited 1×
“There is yet another type of study in which some optical or physiological characteristics of the subjects are objectively measured when they wear PPL and performs certain visual tasks; for example, distortion,(4) eye and head movement,(23) or performance at intermediate vision tasks.(24) There are no thorough studies…”
BackgroundProgressive addition lenses — measurements and ratings
Sheedy, J., Hardy, R. F., & Hayes, J. R. (2006) · Optometry - Journal of the American Optometric Association · doi:10.1016/j.optm.2005.10.019 · Cited by 65
Correlation analysis of the optics of progressive addition lenses
Sheedy, J. E. (2004) · Optometry and Vision Science · doi:10.1097/01.opx.0000134909.51768.5e · Cited by 54 · cited 1×
“These numbers are not freely selectable by the lens designer, as they are linked through the geometrical constraints of the progressive surfaces.(30) In any case, a clinical trial or objective measurement of lens performance may refer its result to this common coordinate system.”
Background
Cited by
Lens design techniques to improve satisfaction in free-form progressive addition lens users
Chamorro, E. (2018) · JOJ Ophthalmology · doi:10.19080/jojo.2018.06.555688 · Cited by 36
“Though most of the lenses used in this study were personalized, the power distribution maps obtained using mapping devices are not representative because the results do not show the perceived power of the user [6].”
BackgroundTheoretical performance of progressive addition lenses with poorly measured individual parameters
Pascual, E., Gómez‐Pedrero, J. A., & Alonso, J. (2023) · Ophthalmic and Physiological Optics · doi:10.1111/opo.13088 · Cited by 11
Self-citationOptical performance of progressive addition lenses (PALs) with astigmatic prescription
De Lestrange-Anginieur, E., & Kee, C. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-82697-0 · Cited by 9
Metadata
- Authors
- Arroyo, R., Crespo, D., & Alonso, J.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2012-04
- Volume
- 89
- Issue
- 4
- Pages
- E489-E501
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2005934429
- Cited by
- 37
- References
- 6
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.