Cardiac output measurement using an ultrasound dilution method: A validation study in ventilated piglets
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess agreement between a new method of cardiac output monitoring, using ultrasound dilution technology and ultrasound transit time-based measurement of pulmonary blood flow in a piglet model. DESIGN: Prospective, experimental juvenile animal study. SETTING: Animal laboratory of a university hospital. SUBJECTS: Nine random-bred piglets. INTERVENTIONS: After the animals received general anesthesia, we placed intravascular arterial and central venous catheters with the tip positioned in the abdominal aorta and the right atrium, respectively. The catheters were connected to the ultrasound dilution cardiac output monitor. An ultrasound transit time perivascular flow probe was positioned around the common pulmonary artery and served as the standard reference measurement. Cardiac output was manipulated during the experiment by creating hemorrhagic hypotension. Ultrasound dilution cardiac output was measured intermittently with injection volumes of 0.5 mL/kg and 1.0 mL/kg of isotonic saline at body temperature. MEASUREMENTS AND MAIN RESULTS: Ultrasound dilution cardiac output (Q) measurement was compared with pulmonary blood flow (Q). Bias, defined as Q minus Q, was calculated for each measurement. Mean bias with standard deviation was calculated for measurements with volumes of injected saline, 0.5 mL/kg and 1.0 mL/kg, and compared using the Mann-Whitney U test. Mean bias (sd) between Q and Q was 0.040 (0.132) and 0.058 (0.136) L/min for measurement with 0.5 mL/kg and 1.0 mL/kg of isotonic saline, respectively (no statistically significant difference). CONCLUSIONS: Ultrasound dilution cardiac output measurement is reliable in piglets with the use of a small volume of a nontoxic indicator (isotonic saline).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224 · cited 1×
“This clinical estimation of cardiac output, based on the interpretation of indirect parameters of systemic blood flow like blood pressure, urine output, capillary refill time, core-peripheral temperature difference, and blood gas analysis has been proven to be unreliable (6).”
Background
Cited by
Noori, S., Drabu, B., Soleymani, S., & Seri, I. (2012) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/fetalneonatal-2011-301090 · Cited by 146
Advanced Hemodynamic Monitoring in the Neonatal Intensive Care Unit
de Boode, W.-P. (2020) · Clinics in Perinatology · doi:10.1016/j.clp.2020.05.001 · Cited by 34
“This technique has extensively been validated in animal models and proved to be safe regarding systemic and cerebral hemodynamic and oxygenation with the use of the extracorporeal loop.(22,23) Moreover, TPUD is also feasible in the presence of a significant transductal left-to-right shunt, in a state of hypovolemic sh…”
MethodSelf-citationNeonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Metadata
- Authors
- de Boode, W. P., van Heijst, A. F. J., Hopman, J. C. W., Tanke, R. B., van der Hoeven, H. G., & Liem, K. D.
- Venue
- Pediatric Critical Care Medicine
- Published
- 2010-01
- Volume
- 11
- Issue
- 1
- Pages
- 103-108
- ISSN
- 1529-7535 (ISSN-L)
- OpenAlex
- W2040811429
- Cited by
- 39
- References
- 2
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac output measurement using an ultrasound dilution method: A validation study in ventilated piglets. https://app.cochat.ai/papers/10.1097/pcc.0b013e3181b064ea
- The paper
- de Boode, W. P., van Heijst, A. F. J., Hopman, J. C. W., Tanke, R. B., van der Hoeven, H. G., & Liem, K. D. (2010). Cardiac output measurement using an ultrasound dilution method: A validation study in ventilated piglets. Pediatric Critical Care Medicine. https://doi.org/10.1097/pcc.0b013e3181b064ea
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.