Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Open accessAbstract
OBJECTIVES: To evaluate the ability of clinicians involved in the provision of paediatric intensive care to estimate cardiac index in ventilated children, based on physical examination and clinical and bedside laboratory data. METHODS: Clinicians were exposed to all available haemodynamic and laboratory data for each patient, allowed to make a physical examination, and asked to first categorize cardiac index as high, high to normal, low to normal, or low, and then to quantify this further with a numerical estimate. Cardiac index was measured simultaneously by femoral artery thermodilution (coefficient of variation 5.37%). One hundred and twelve estimates were made by 27 clinicians on 36 patients (median age 34.5 months). RESULTS: Measured cardiac index ranged from 1.39 to 6.84 1/min/m2. Overall, there was poor correlation categorically (kappa statistic 0.09, weighted kappa 0.169) and numerically (r = 0.24, 95% confidence interval 0.06 to 0.41), although some variation was seen among the various levels of seniority. CONCLUSION: Assuming that objective measurement, and hence manipulation, of haemodynamic variables may improve outcome, these findings support the need for a safe, accurate, and repeatable technique for measurement of cardiac index in children who are critically ill.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Low cardiac output state is accurately clinically recognized in only 25% of cases in pediatric intensive care units.
“Low cardiac output state is accurately clinically recognized in only 25% of cases in pediatric intensive care units [10].”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [10]
Table 1 (Discussion; page unavailable) shows that clinicians correctly classified 12 of 47 measured low-cardiac-index estimates as low—about 25%. The Patients and methods section specifies that these estimates concerned ventilated, sedated children, so the result does not establish a 25% recognition rate for all pediatric intensive care patients. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Practical Statistics for Medical Research.
Walter, S., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,665 · see citing works
Practical Statistics for Medical Research.
Bartko, J. J., & Altman, D. G. (1992) · Journal of the American Statistical Association · doi:10.2307/2290246 · Cited by 4,834 · see citing works
Connors, A., Speroff, T., Dawson, N., Thomas, C. L., Harrell, F., Wagner, D., Desbiens, N., Goldman, L., Wu, A. W., Califf, R., et al. (1996) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.276.11.889 · Cited by 2,383 · see citing works
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA · doi:10.1001/jama.1996.03540110043030 · Cited by 2,239 · see citing works
Elevation of Systemic Oxygen Delivery in the Treatment of Critically Ill Patients
Hayes, M., Timmins, A. C., Yau, E. H. S., Palazzo, M. G. A., Hinds, C., & Watson, D. I. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406163302404 · Cited by 1,530 · see citing works
A Trial of Goal-Oriented Hemodynamic Therapy in Critically Ill Patients
Gattinoni, L., Brazzi, L., Pelosi, P. P., Latini, R., Tognoni, G., Pesenti, A. M., & Fumagalli, R. (1995) · New England Journal of Medicine · doi:10.1056/nejm199510193331601 · Cited by 1,486 · see citing works
Randomized Evaluation of Pulse Oximetry in 20,802 Patients; II
Møller, J. T., JOHANNESSEN, N. W., Espersen, K., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199303000-00007 · Cited by 444 · see citing works
Eisenberg, P. R., Jaffe, A. S., & Schuster, D. P. (1984) · Critical Care Medicine · doi:10.1097/00003246-198407000-00001 · Cited by 397 · see citing works
Connors, A. F., McCaffree, D. R., & Gray, B. A. (1983) · New England Journal of Medicine · doi:10.1056/nejm198302033080508 · Cited by 365 · see citing works
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically Ill Patients
Connors, A. F., Speroff, T., Dawson, N. V., Thomas, C. L., Harrell, F. E., Wagner, D. P., Desbiens, N. A., Goldman, L., Wu, A. W., Califf, R. M., et al. (1997) · Survey of Anesthesiology · doi:10.1097/00132586-199708000-00004 · Cited by 226 · see citing works
Pulmonary artery catheterization in critically ill patients
Mimoz, O., Rauss, A., REKIK, N., Brun‐Buisson, C., Lemaire, F., & Brochard, L. J. (1994) · Critical Care Medicine · doi:10.1097/00003246-199404000-00011 · Cited by 201 · see citing works
Distributions of cardiopulmonary variables in pediatric survivors and nonsurvivors of septic shock
Pollack, M. M., Fields, A. I., & Ruttimann, U. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198506000-00002 · Cited by 117 · see citing works
Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU.
Steingrub, J., Celoria, G., Vickers-Lahti, M., Teres, D., & Bria, W. (1991) · Chest · doi:10.1378/chest.99.6.1451 · Cited by 113 · see citing works
McLuckie, A., Murdoch, I., Marsh, M., & Anderson, D. R. (1996) · Acta Paediatrica · doi:10.1111/j.1651-2227.1996.tb14027.x · Cited by 90 · see citing works
Self-citationComplications of vascular catheterization in critically ill children
Smith-Wright, D. L., Green, T. P., Lock, J. E., EGAR, M., & Fuhrman, B. P. (1984) · Critical Care Medicine · doi:10.1097/00003246-198412000-00001 · Cited by 64 · see citing works
Impact of hemodynamic monitoring in a medical intensive care unit
Tuchschmidt, J. A., & SHARMA, P. (1987) · Critical Care Medicine · doi:10.1097/00003246-198709000-00008 · Cited by 51 · see citing works
A new paediatric metabolic monitor
Weyland, W., Weyland, A., Fritz, U., Redecker, K., Ensink, F. B. M., & Braun, U. (1994) · Intensive Care Medicine · doi:10.1007/bf02425058 · Cited by 40 · see citing works
Continuous haemodynamic monitoring in children: use of transoesophageal Doppler
Murdoch, I., Marsh, M., Tibby, S. M., & McLuckie, A. (1995) · Acta Paediatrica · doi:10.1111/j.1651-2227.1995.tb13751.x · Cited by 39 · see citing works
Self-citationClinical assessment of hemodynamic values in two surgical intensive care units. Effects on therapy.
Celoria, G., Steingrub, J., Vickers-Lahti, M., Teres, D., Stein, K., Fink, M. P., & Friedmann, P. (1990) · Archives of Surgery · doi:10.1001/archsurg.1990.01410200100016 · Cited by 36 · see citing works
Measurement of Cardiac Output in Children
Murdoch, I., Marsh, M. J., & Morrison, G. (1995) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-642-79154-3_49 · Cited by 23 · see citing works
Self-citationO’Connell, A., Tibballs, J., & Coulthard, M. G. (1991) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9101900323 · Cited by 22 · see citing works
Impact of Hemodynamic Monitoring in a Medical Intensive Care Unit
Tuchschmidt, J. A., & Sharma, O. P. (1988) · Survey of Anesthesiology · doi:10.1097/00132586-198804000-00026 · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- Murdoch IA, Marsh MJ, Morrison G. Measurement of car- diac output in children. In: Vincent J-L, ed. 1995 yearbook of intensive care and emergency medicine. Berlin: Springer, 1995:606-14.
- Celoria G, Steingrub JS, Vickers-Lahti M, et al. Clinical assessment of hemodynamic values in two surgical intensive care units. Arch Surg 1990;125:1036-9.
- Pollack MM, Fields AI, Ruttimann UE. Distribution of car- diopulmonary variables in pediatric survivors of septic shock. Crit Care Med 1985;13:454-9.
- Murdoch IA, Marsh MJ, Tibby SM, McLuckie A. Continu- ous haemodynamic monitoring in children: use of tran- soesophageal Doppler. Acta Paediatr 1995;84:761-4.
Cited by
Sorted by citations
Chew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151 · see citing works
Clinical monitoring of systemic hemodynamics in critically ill newborns
de Boode, W.-P. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.01.031 · Cited by 87 · see citing works
Singh, Y., Villaescusa, J. U., da Cruz, E. M., Tibby, S. M., Bottari, G., Saxena, R., Guillén, M., Herce, J. L., Di Nardo, M., Cecchetti, C., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03326-2 · Cited by 86 · see citing works
Self-citationSchey, B. M., Williams, D. Y., & Bucknall, T. (2010) · Heart & Lung · doi:10.1016/j.hrtlng.2009.04.002 · Cited by 40 · see citing works
Narula, J., Chauhan, S., Ramakrishnan, S., & Gupta, S. K. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.12.009 · Cited by 39 · see citing works
Advanced Hemodynamic Monitoring in the Neonatal Intensive Care Unit
de Boode, W.-P. (2020) · Clinics in Perinatology · doi:10.1016/j.clp.2020.05.001 · Cited by 34 · see citing works
Bridier, A., Shcherbakova, M., Kawaguchi, A., Poirier, N., Said, C., Noumeir, R., & Jouvet, P. (2023) · Frontiers in Pediatrics · doi:10.3389/fped.2023.1083962 · Cited by 6 · see citing works
The Gold Standard of Pediatric Hemodynamic Monitoring: Not All That Glitters Is Gold
Ricci, Z., Iacobelli, R., & Romagnoli, S. (2023) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006215 · Cited by 4 · see citing works
Nedelcu, C., Ionescu, N. S., Bizubac, A. M., Filip, C., & Cirstoveanu, C. (2025) · Life · doi:10.3390/life15101621 · Cited by 2 · see citing works
“Low cardiac output state is accurately clinically recognized in only 25% of cases in pediatric intensive care units [10].”
- Authors
- Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A.
- Affiliations
- Guy's Hospital (GB)
- Venue
- Archives of Disease in Childhood
- Publisher
- BMJ
- Published
- 1997-12-01
- Volume
- 77
- Issue
- 6
- Pages
- 516-518
- ISSN
- 0003-9888 (ISSN-L)
- 1468-2044
- PMC
- PMC1717412
- OpenAlex
- W2005219150
- Cited by
- 224
- References
- 22
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 9 · 2023: 10 · 2022: 6 · 2021: 3 · 2020: 18 · 2019: 12 · 2018: 10 · 2017: 10 · 2016: 15 · 2015: 11 · 2014: 9 · 2013: 19 · 2012: 10
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Archives of Disease in Childhood (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Epidemiology › Sepsis Diagnosis and Treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Keywords
- cardiac index, pediatric intensive care, mechanically ventilated children, infants, hemodynamic assessment, thermodilution, physical examination
- MeSH terms
- Body Surface Area, Cardiac Output, Child, Child, Preschool, Clinical Competence, Humans, Infant, Respiration, Artificial, Thermodilution, Intensive Care Units, Pediatric
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review