CoChat

Vasoactive-inotropic score as a predictor of morbidity and mortality in infants after cardiopulmonary bypass

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Inotrope score has been proposed as a marker of illness severity after pediatric cardiac surgery despite a lack of data to support its use as such. The goal of this study was to determine the association between inotropic/vasoactive support and clinical outcome in infants after cardiac surgery. DESIGN: Retrospective chart review. SETTING: Dedicated pediatric cardiothoracic intensive care unit at an academic, tertiary care medical center. PATIENTS: One hundred seventy-four patients 0 to 6 months of age admitted to the cardiothoracic intensive care unit after cardiac surgery with cardiopulmonary bypass between August 2007 and June 2008. Forty-three percent were neonates, and 39% had functional single ventricle physiology. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Hourly doses of all vasoactive medications were recorded for the first 48 hrs after admission to the cardiothoracic intensive care unit and a vasoactive-inotropic score was calculated. The maximum vasoactive-inotropic score level over the first 48 hrs was a good predictor of poor clinical outcome (death, cardiac arrest, mechanical circulatory support, renal replacement therapy, and/or neurologic injury). After controlling for diagnosis, high maximum vasoactive-inotropic score was strongly associated with a poor outcome with an adjusted odds ratio of 8.1 (95% confidence interval, 3.4-19.2; p < .001) compared with patients with a low maximum vasoactive-inotropic score. High vasoactive-inotropic score was also associated with prolonged cardiothoracic intensive care unit stay, duration of mechanical ventilation, and time to negative fluid balance. CONCLUSIONS: The amount of cardiovascular support in the first 48 hrs after congenital heart surgery with cardiopulmonary bypass predicts eventual morbidity and mortality in young infants. The degree of support is best characterized by a maximum vasoactive-inotropic score obtained during this period. The usefulness of vasoactive-inotropic score as an independent predictor of clinical outcome in infants after cardiac surgery may have important implications for future cardiothoracic intensive care unit research.

Overview

Integrity signals

Registry

Crossref · 10.1097/pcc.0b013e3181b806fc

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 18 references

Research works printed but not linked: 2

  1. Kulik, 1996, Circulation, 94, II63
  2. Zhang, 2008, Circulation, 118, S750

Cited by

Items 901–1,000 of 1,317

Metadata

Authors
Gaies, M. G., Gurney, J. G., Yen, A. H., Napoli, M. L., Gajarski, R. J., Ohye, R. G., Charpie, J. R., & Hirsch, J. C.
Affiliations
University of Michigan (US)
Venue
Pediatric Critical Care Medicine
Published
2010-03
Volume
11
Issue
2
Pages
234-238
ISSN
1529-7535 (ISSN-L)
OpenAlex
W2002926363
Cited by
1,325
References
18
Citations by year
2026: 112 · 2025: 130 · 2024: 137 · 2023: 141 · 2022: 119 · 2021: 117 · 2020: 92 · 2019: 82 · 2018: 76 · 2017: 78 · 2016: 67 · 2015: 49 · 2014: 46 · 2013: 41 · 2012: 20
FWCI
17.45
Type
journal article
Language
en
Open access
closed
Locations
  • Pediatric Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Surgery › Cardiac and Coronary Surgery Techniques
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
vasoactive-inotropic score, inotropic support, vasoactive drugs, pediatric cardiac surgery, cardiopulmonary bypass, infants, mortality prediction, morbidity, single ventricle, mechanical circulatory support, renal replacement therapy, neurologic injury, length of hospital stay, mechanical ventilation
MeSH terms
Cardiopulmonary Bypass, Heart Defects, Congenital, Humans, Infant, Infant, Newborn, Medical Audit, Myocardial Contraction, Predictive Value of Tests, Retrospective Studies, Severity of Illness Index, Vasodilator Agents, Intensive Care Units, Pediatric, Outcome Assessment, Health Care

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.