Point-of-Care Echocardiography by Pediatric Emergency Physicians
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Currently, pediatric emergency medicine (PEM) physicians have limited data on point-of-care echocardiography (POCE). Our goals were to (1) determine the overall accuracy of POCE by PEMs in assessing left ventricular (LV) systolic function visually, presence or absence of pericardial effusion, and cardiac preload by estimating inferior vena cava (IVC) collapsibility, in acutely ill children in the pediatric emergency department; and (2) assess interobserver agreement between the PEM physician and pediatric cardiologist. METHODS: This is a prospective, observational study conducted in an urban, tertiary pediatric facility with an annual census of 67,000 emergency department visits. Patients between the ages of 0 and 18 years meeting 1 or more of the following inclusion criteria were recruited: (1) cardiopulmonary arrest, (2) fluid refractory shock requiring vasoactive infusions, (3) undifferentiated cardiomegaly on chest radiography, and (4) receiving emergent formal echocardiography. All eligible patients underwent POCE by 1 of 2 trained PEM physicians. Dynamic video clips were recorded and reviewed by a pediatric cardiologist who was unaware of the clinical condition of the study patients. RESULTS: For a period of 18 months, we recruited 70 patients. Diminished LV function was noted in 17, pericardial effusion in 16, and abnormal IVC collapsibility in 35 patients. The κ statistics of agreement between the PEM and the cardiologist for detection of LV function, IVC collapsibility, and effusion were 0.87 (95% confidence interval [CI], 0.73-1.00), 0.73 (95% CI, 0.59-0.88), and 0.77 (95% CI, 0.58-0.95), respectively. The overall sensitivity and specificity of POCE compared with a formal echocardiogram was 95% (95% CI, 82%-99%) and 83% (95% CI, 64%-93%), respectively. CONCLUSIONS: With goal-directed training, PEM physicians may be able to perform POCE and accurately assess for significant LV systolic dysfunction, vascular filling, and the presence of pericardial effusion. The model may be expanded to train physicians to use POCE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probable Inference, the Law of Succession, and Statistical Inference
Wilson, E. B. (1927) · Journal of the American Statistical Association · doi:10.1080/01621459.1927.10502953 · Cited by 4,476
McGee, S. (1999) · JAMA · doi:10.1001/jama.281.11.1022 · Cited by 583
Cited by
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
International Evidence-Based Recommendations for Focused Cardiac Ultrasound
Via, G., Hussain, A., Wells, M., Reardon, R., ElBarbary, M., Noble, V. E., Tsung, J. W., Neskovic, A. N., Price, S., Oren-Grinberg, A., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.05.001 · Cited by 587
Marino, B. S., Tabbutt, S., MacLaren, G., Hazinski, M. F., Adatia, I., Atkins, D. L., Checchia, P. A., DeCaen, A., Fink, E. L., Hoffman, G. M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000524 · Cited by 203
Echocardiographic Evaluation of Hemodynamics in Neonates and Children
Singh, Y. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00201 · Cited by 116
Ficial, B., Finnemore, A. E., Cox, D. J., Broadhouse, K. M., Price, A. N., Durighel, G., Ekitzidou, G., Hajnal, J. V., Edwards, A. D., & Groves, A. M. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.08.019 · Cited by 102
Metadata
- Authors
- Longjohn, M., Wan, J., Joshi, V., & Pershad, J.
- Venue
- Pediatric Emergency Care
- Published
- 2011-08
- Volume
- 27
- Issue
- 8
- Pages
- 693-696
- ISSN
- 0749-5161 (ISSN-L)
- OpenAlex
- W2078428169
- Cited by
- 106
- References
- 2
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.