CoChat

Physicochemical Decellularization of Composite Flexor Tendon–Bone Interface Grafts

Bronstein, Joel A., Woon, Colin Y. L., Farnebo, Simon, Behn, Anthony W., Schmitt, Taliah, Pham, Hung, Castillo, Alesha B., Chang, James · 2013 · Plastic and Reconstructive Surgery
Cited by 28

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Extremity injuries involving tendon attachment to bone are difficult to address. Clinically, tendon-bone interface allografts must be decellularized to reduce immunogenicity. Composite grafts are difficult to decellularize because chemical agents cannot reach cells between tissues. In this study, the authors attempted to optimize tendon-bone interface graft decellularization. METHODS: Human flexor digitorum profundus tendons with attached distal phalanx were harvested from cadavers and divided into four groups. Group 1 (control) was untreated. Group 2 (chemical) was chemically treated with 5% peracetic acid, 0.1% ethylenediaminetetraacetic acid, and 0.1% sodium dodecyl sulfate. Group 3 (low-power) underwent targeted ultrasonication for 3 minutes (22,274 J, 126W) followed by chemical decellularization. Group 4 (high-power) underwent targeted ultrasonication for 10 minutes (88,490 J, 155W) followed by chemical decellularization. Decellularization was assessed histologically with hematoxylin and eosin stain and stains for major histocompatibility complex I stains. Cell counts were performed. The ultimate tensile load of decellularized grafts (group 4) were compared with pair-matched untreated grafts (group 1). RESULTS: Average cell counts were 100 ± 41, 27 ± 10, 12 ± 11, and 6 ± 11 per high-power field for groups 1, 2, 3, and 4, respectively (p < 0.001). Decellularization using physical and chemical treatments (groups 3 and 4) resulted in substantial reduction of cells and major histocompatibility complex I molecules. There was no difference in ultimate tensile load between treated (group4) and untreated (group 1) samples (p > 0.5). CONCLUSIONS: Physicochemical decellularization of tendon-bone interface grafts using targeted ultrasonication and chemical treatment resulted in near-complete reduction in cellularity and maintenance of tensile strength. In the future, these decellularized composite scaffolds may be used for reconstruction of tendon-bone injuries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/prs.0b013e318290f5fc

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 28

Metadata

Authors
Bronstein, J. A., Woon, C. Y. L., Farnebo, S., Behn, A. W., Schmitt, T., Pham, H., Castillo, A. B., & Chang, J.
Venue
Plastic and Reconstructive Surgery
Published
2013-07
Volume
132
Issue
1
Pages
94-102
ISSN
0032-1052 (ISSN-L)
OpenAlex
W1979057640
Cited by
28
References
1
FWCI
3.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.