CoChat

A Randomized Controlled Trial of Secondary Prevention of Anxiety and Distress in a German Sample of Patients With an Implantable Cardioverter Defibrillator

Crössmann, Alexander, Schulz, Stefan M., Kühlkamp, Volker, Ritter, Oliver, Neuser, Hans, Schumacher, Burghard, Bauer, Wolfgang, Pauli, Paul · 2010 · Psychosomatic Medicine
Cited by 55

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objective: To evaluate a minimal, easy, accessible intervention targeting anxiety and reduced quality of life in patients with an implantable cardioverter defibrillator (ICD). An estimated 24% to 87% of patients experience anxiety, and 10% to 15% have reduced quality of life. Methods: A total of 119 ICD patients were assigned randomly to usual medical aftercare (n = 63) or additional psychological treatment (n = 56) comprising of written information on medical and psychological consequences of an ICD plus 6 months of individual phone counseling. Treatment efficacy was evaluated by comparing T0 (immediately after implantation) and T1 (6 months later) assessments. Results: Although 75% of patients considered the program helpful, age moderated treatment efficacy. As indicated by triple interactions, only in the treatment group, anxiety (HADS-Anxiety, p < .01), psychological distress (SCL-K-9, p < .02), and somatic quality of life (SF-36-PCS, p < .01) improved in ICD patients aged <65 years but deteriorated in older patients (age, 65–75 years). Frequency of ICD discharges was associated with a symptom increase from T0 to T1 in all patients (HADS-Depression, CAQ-Avoidance, and ICD-Constraints; all p < .05). Conclusions: Our findings confirm that psychological treatments cannot be expected to have uniformly positive effects in ICD patients. Our minimal intervention may have adequately addressed ICD-related concerns in younger patients but may have fostered problems in older patients with fewer concerns. Therefore, our findings warrant custom treatment with particular attention to the elderly as well as patients with frequent ICD discharges. ANOVA = analysis of variance; ATP = antitachycardia pacing; BMI = body mass index; CAQ = Cardiac Anxiety Questionnaire; HADS = Hospital Anxiety and Depression Scale; ICD = implantable cardioverter defibrillator; MI = myocardial infarction; MANOVA = multivariate analysis of variance; QoL = quality of life; SCL-K-9 = Symptom Checklist, 9-item short form; SF-36-MCS = Medical Outcome Study Short Form-36 Health Survey: mental component summary; SF-36-PCS = Medical Outcome Study Short Form-36 Health Survey: physical component summary; T0 = assessment immediately after ICD implantation; T1 = assessment at the end of the intervention (i.e., 6 months later).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/psy.0b013e3181d9bcec

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Crössmann, A., Schulz, S. M., Kühlkamp, V., Ritter, O., Neuser, H., Schumacher, B., Bauer, W., & Pauli, P.
Venue
Psychosomatic Medicine
Published
2010-06
Volume
72
Issue
5
Pages
434-441
ISSN
0033-3174 (ISSN-L)
OpenAlex
W1982256184
Cited by
55
References
6
FWCI
5.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.