High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images: Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-based contrast agent gadobutrol. MATERIALS AND METHODS: Thirty patients who had received at least 5 MRI examinations (plus an additional last MRI for reference) with the exclusive use of gadobutrol, resulting in a total cumulative dose of 54.1 ± 30.4 mL gadobutrol, were analyzed retrospectively. Signal intensity ratio differences were calculated for DN-to-pons, DN-to-CSF, and GP-to-thalamus ratios by subtracting the SI ratio at the first MRI from the SI ratio at the last MRI scan. One-sample t tests were employed to examine if they differed from 0. Regression and correlational analyses were performed to examine whether the SI ratio differences were predicted by a number of control variables. RESULTS: Signal intensity ratio differences did not differ significantly from 0, neither for the DN-to-pons ratio (-0.0035 ± 0.0476, P = 0.69), the DN-to-CSF ratio (-0.0539 ± 0.3217, P = 0.37), nor the GP-to-thalamus ratio (-0.0020 ± 0.0211, P = 0.60). None of the control variables predicted changes in SI ratios. CONCLUSIONS: In contrast to a recently published study, we did not find signal increases in the DN or in the GP after serial injections of gadobutrol, even though the total dose applied here was considerably larger than in the respective study. This finding adds further support to the hypothesis that the molecular structure of a gadolinium-based contrast agent as either macrocyclic or linear is a crucial factor for its potential to cause gadolinium deposition in the brain. Future studies should further assess this hypothesis by additional animal investigations as well as histopathological and clinical correlation studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayesian t tests for accepting and rejecting the null hypothesis
Rouder, J. N., Speckman, P. L., Sun, D., Morey, R. D., & Iverson, G. (2009) · Psychonomic Bulletin & Review · doi:10.3758/pbr.16.2.225 · Cited by 3,688 · cited 1×
“We supplemented our analyses with Jeffreys-Zellner-SiowBayes factors to quantify the strength of evidence in favor of the null hypothesis (mean/correlation not different from 0) or the alternative hypothesis (mean/correlation different from 0).(17,18)”
MethodIntracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.2015142690 · Cited by 874
Radbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561 · cited 4×
“The image analysis was conducted as described previously by Radbruch et al.6 All images were reviewed on a workstation using our picture archiving and communication system.”
MethodSelf-citationStability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181852171 · Cited by 539 · cited 2×
“While mcGBCAs seemed stable in human serum in this study, linear GBCAs (lGBCAs) released a significant amount of Gd into the serum.(4) The difference in in vivo stability of GBCAs is further thought to be correlated with the GBCA's potential to cause nephrogenic systemic fibrosis (NSF).”
BackgroundA default Bayesian hypothesis test for correlations and partial correlations
Wetzels, R., & Wagenmakers, E.-J. (2012) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0295-x · Cited by 510 · cited 1×
“We supplemented our analyses with Jeffreys-Zellner-SiowBayes factors to quantify the strength of evidence in favor of the null hypothesis (mean/correlation not different from 0) or the alternative hypothesis (mean/correlation different from 0).(17,18)”
MethodKanda, T., Osawa, M., Oba, H., Toyoda, K., Kotoku, J., Haruyama, T., Takeshita, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.14140364 · Cited by 492
Thomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441 · cited 2×
“This is taken into account by the classification system of GBCAs by the Contrast Media Guidelines from the Contrast Media Safety Committee of the European Society of Urogenital Radiology; it classifies all mcGBCAs as having the lowest risk for inducing NSF, whereas all lGBCAs are either classified as having a high or…”
MethodErrante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
Enzmann, D. R., & Pelc, N. J. (1991) · Radiology · doi:10.1148/radiology.178.2.1987610 · Cited by 364 · cited 1×
“The use of CSF as a comparator, on the other hand, is hampered bymotion and pulsation artifacts caused by the physiologic flow of CSF during systole and diastole.(20) Generally, the authors of this study favor the DN-to-pons ratio over the DN-to-CSF ratio because the pons has a more homogenous appearance than the CSF,…”
BackgroundRobert, P., Lehericy, S., Grand, S., Violas, X., Fretellier, N., Idée, J.-M., Ballet, S., & Corot, C. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000181 · Cited by 257
Ramalho, J., Castillo, M., AlObaidy, M., Nunes, R. H., Ramalho, M., Dale, B. M., & Semelka, R. C. (2015) · Radiology · doi:10.1148/radiol.2015150872 · Cited by 230
Weberling, L. D., Kieslich, P. J., Kickingereder, P., Wick, W., Bendszus, M., Schlemmer, H.-P., & Radbruch, A. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000206 · Cited by 168 · cited 1×
“Interestingly, a significant negative correlation between the mean time interval between scans and the SI increase for the DN-to-pons ratio is also reported by Weberling et al15 in a study on the lGBCA gadobenate dimeglumine.”
BackgroundSelf-citationRoccatagliata, L., Vuolo, L., Bonzano, L., Pichiecchio, A., & Mancardi, G. (2009) · Radiology · doi:10.1148/radiol.2511081269 · Cited by 106
Cited by
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Gadolinium deposition in the brain: summary of evidence and recommendations
Gulani, V., Calamante, F., Shellock, F. G., Kanal, E., & Reeder, S. B. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30158-8 · Cited by 784
Murata, N., Gonzalez-Cuyar, L. F., Murata, K., Fligner, C., Dills, R., Hippe, D., & Maravilla, K. R. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000252 · Cited by 408
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Paolini, M. A., Murray, D. L., Williamson, E. E., & Eckel, L. J. (2017) · Radiology · doi:10.1148/radiol.2017161595 · Cited by 318
Robert, P., Violas, X., Grand, S., Lehericy, S., Idée, J.-M., Ballet, S., & Corot, C. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000241 · Cited by 212
“However, this study has methodological limitations(12,24,25) and was not confirmed by a recent study performed in 30 patients (no T1 signal increases in the dentate nucleus or in the globus pallidus after serial administrations of gadobutrol).(15) As in the case of nephrogenic systemic fibrosis, the hypothesis of a re…”
Result
Metadata
- Authors
- Radbruch, A., Weberling, L. D., Kieslich, P. J., Hepp, J., Kickingereder, P., Wick, W., Schlemmer, H.-P., & Bendszus, M.
- Venue
- Investigative Radiology
- Published
- 2015-12
- Volume
- 50
- Issue
- 12
- Pages
- 805-810
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2400913366
- Cited by
- 201
- References
- 15
- FWCI
- 29.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.