CoChat

Precise and Automatic Patient Positioning in Computed Tomography: Avatar Modeling of the Patient Surface Using a 3-Dimensional Camera

Open access
Saltybaeva, Natalia, Schmidt, Bernhard, Wimmer, Andreas, Flohr, Thomas, Alkadhi, Hatem · 2018 · Investigative Radiology
Cited by 91

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objectives: The aim of this study was to evaluate the accuracy of a 3-dimensional (3D) camera algorithm for automatic and individualized patient positioning based on body surface detection and to compare the results of the 3D camera with manual positioning performed by technologists in routinely obtained chest and abdomen computed tomography (CT) examinations. Materials and Methods: This study included data of 120 patients undergoing clinically indicated chest (n = 68) and abdomen (n = 52) CT. Fifty-two of the patients were scanned with CT using a table height manually selected by technologists; 68 patients were automatically positioned with the 3D camera, which is based on patient-specific body surface and contour detection. The ground truth table height (T GT) was defined as the table height that aligns the axial center of the patient’s body region in the CT scanner isocenter. Off-centering was defined as the difference between the ground truth table height (T GT) and the actual table position used in all CT examinations. The t test was performed to determine significant differences in the vertical offset between automatic and manual positioning. The χ 2 test was used to check whether there was a relationship between patient size and the magnitude of off-centering. Results: We found a significant improvement in patient centering (offset 5 ± 3 mm) when using the automatic positioning algorithm with the 3D camera compared with manual positioning (offset 19 ± 10 mm) performed by technologists (P < 0.005). Automatic patient positioning based on the 3D camera reduced the average offset in vertical table position from 19 mm to 7 mm for chest and from 18 mm to 4 mm for abdomen CT. The absolute maximal offset was 39 mm and 43 mm for chest and abdomen CT, respectively, when patients were positioned manually, whereas with automatic positioning using the 3D camera the offset never exceeded 15 mm. In chest CT performed with manual patient positioning, we found a significant correlation between vertical offset greater than 20 mm and patient size (body mass index, >26 kg/m 2, P < 0.001). In contrast, no such relationship was found for abdomen CT (P = 0.38). Conclusions: Automatic individualized patient positioning using a 3D camera allows for accurate patient centering as compared with manual positioning, which improves radiation dose utilization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rli.0000000000000482

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 91

Metadata

Authors
Saltybaeva, N., Schmidt, B., Wimmer, A., Flohr, T., & Alkadhi, H.
Venue
Investigative Radiology
Published
2018-11
Volume
53
Issue
11
Pages
641-646
ISSN
  • 0020-9996 (ISSN-L)
  • 1536-0210
OpenAlex
W2804654737
Cited by
91
References
1
FWCI
5.67
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.