The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Recent and Upcoming Technological Developments in Computed Tomography: High Speed, Low Dose, Deep Learning, Multienergy
Abstract
The advent of computed tomography (CT) has revolutionized radiology, and this revolution is still going on. Starting as a pure head scanner, modern CT systems are now able to perform whole-body examinations within a couple of seconds in isotropic resolution, single-rotation whole-organ perfusion, and temporal resolution to fulfill the needs of cardiac CT. Because of the increasing number of CT examinations in all age groups and overall medical-driven radiation exposure, dose reduction remains a hot topic. Although fast gantry rotation, broad detector arrays, and different dual-energy solutions were main topics in the past years, new techniques such as photon counting detectors, powerful x-ray tubes for low-kV scanning, automated image preprocessing, and machine learning algorithms have moved into focus today. The aim of this article is to give an overview of the technical specifications of up-to-date available CT systems and recent hardware and software innovations for CT systems in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Image-to-Image Translation with Conditional Adversarial Networks
Isola, P., Zhu, J.-Y., Zhou, T., & Efros, A. A. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.632 · Cited by 22,930
Multilayer feedforward networks are universal approximators
Hornik, K., Stinchcombe, M., & White, H. (1989) · Neural Networks · doi:10.1016/0893-6080(89)90020-8 · Cited by 21,728
GAN(Generative Adversarial Nets)
(2017) · Journal of Japan Society for Fuzzy Theory and Intelligent Informatics · doi:10.3156/jsoft.29.5_177_2 · Cited by 19,270
Photon-counting CT: Technical Principles and Clinical Prospects
Willemink, M. J., Persson, M., Pourmorteza, A., Pelc, N. J., & Fleischmann, D. (2018) · Radiology · doi:10.1148/radiol.2018172656 · Cited by 1,326
Generative Adversarial Networks for Noise Reduction in Low-Dose CT
Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2708987 · Cited by 1,037
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Quantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements
Kalender, W. A., Wolf, H., & Suess, C. (1999) · Medical Physics · doi:10.1118/1.598738 · Cited by 345
Cited by
Transformers in medical imaging: A survey
Shamshad, F., Khan, S., Zamir, S. W., Khan, M. H., Hayat, M., Khan, F. S., & Fu, H. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102802 · Cited by 1,296
Euler, A., Nowak, T., Bucher, B., Eberhard, M., Schmidt, B., Flohr, T. G., Frey, D., Distler, O., & Alkadhi, H. (2021) · Investigative Radiology · doi:10.1097/rli.0000000000000781 · Cited by 19
Simplified size adjusted dose reference levels for adult CT examinations: A regional study
Moghadam, N., Lecomte, R., Mercure, S., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109861 · Cited by 16
Metadata
- Authors
- Lell, M. M., & Kachelrieß, M.
- Venue
- Investigative Radiology
- Published
- 2019-09-17
- Volume
- 55
- Issue
- 1
- Pages
- 8-19
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W2974549447
- Cited by
- 254
- References
- 53
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent and Upcoming Technological Developments in Computed Tomography: High Speed, Low Dose, Deep Learning, Multienergy. https://app.cochat.ai/papers/10.1097/rli.0000000000000601
- The paper
- Lell, M. M., & Kachelrieß, M. (2020). Recent and Upcoming Technological Developments in Computed Tomography: High Speed, Low Dose, Deep Learning, Multienergy. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.