Modeling Surgical Technical Skill Using Expert Assessment for Automated Computer Rating
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Objective: Computer vision was used to predict expert performance ratings from surgeon hand motions for tying and suturing tasks. Summary Background Data: Existing methods, including the objective structured assessment of technical skills (OSATS), have proven reliable, but do not readily discriminate at the task level. Computer vision may be used for evaluating distinct task performance throughout an operation. Methods: Open surgeries was videoed and surgeon hands were tracked without using sensors or markers. An expert panel of 3 attending surgeons rated tying and suturing video clips on continuous scales from 0 to 10 along 3 task measures adapted from the broader OSATS: motion economy, fluidity of motion, and tissue handling. Empirical models were developed to predict the expert consensus ratings based on the hand kinematic data records. Results: The predicted versus panel ratings for suturing had slopes from 0.73 to 1, and intercepts from 0.36 to 1.54 (Average R 2 = 0.81). Predicted versus panel ratings for tying had slopes from 0.39 to 0.88, and intercepts from 0.79 to 4.36 (Average R 2 = 0.57). The mean square error among predicted and expert ratings was consistently less than the mean squared difference among individual expert ratings and the eventual consensus ratings. Conclusions: The computer algorithm consistently predicted the panel ratings of individual tasks, and were more objective and reliable than individual assessment by surgical experts.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CV is also starting to emerge in open surgery settings 128 , of which there is a significant volume.”
From Deep learning-enabled medical computer vision (2021) · cites this paper as [128]
Citations
Cites
A new look at the statistical model identification
Akaike, H. (1974) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1974.1100705 · Cited by 51,879 · cited 1×
“The models were optimized using the Akaike information criterion to balance the prediction against the number of variables.(45) Every consensus rating scale (fluidity of motion, motion economy, tissue handling) was first modeled for each distinct category of surgery (ie, SBW, SBA, SCA, TBW, TSF, TDP).”
Objective structured assessment of technical skill (OSATS) for surgical residents
Martin, J. A., Regehr, G., Reznick, R., Macrae, H., Murnaghan, J., Hutchison, C., & Brown, M. (1997) · British Journal of Surgery · doi:10.1002/bjs.1800840237 · Cited by 2,527
The Visual Analysis of Human Movement: A Survey
Gavrila, D. M. (1999) · Computer Vision and Image Understanding · doi:10.1006/cviu.1998.0716 · Cited by 1,782 · cited 1×
“C omputer vision technologies utilize digital cameras and computer algorithms for tracking motions, classifying information, detecting features, and recognizing patterns in digital images and videos.(1) It has impacted a diverse field of applications, ranging from industrial robotics, intelligent and autonomous vehicl…”
Teaching Surgical Skills — Changes in the Wind
Reznick, R. K., & MacRae, H. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054785 · Cited by 1,761
Surgical skill and complication rates after bariatric surgery
Birkmeyer, J. D., Finks, J. F., O'Reilly, A., Oerline, M., Carlin, A. M., Nunn, A. R., Dimick, J., Banerjee, M., & Birkmeyer, N. J. O. (2013) · New England Journal of Medicine · doi:10.1056/nejmsa1300625 · Cited by 1,504
Testing technical skill via an innovative “bench station” examination
Reznick, R., Regehr, G., MacRae, H., Martin, J., & McCulloch, W. (1997) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)89597-9 · Cited by 1,048
Recent developments in human motion analysis
Wang, L., Hu, W., & Tan, T. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(02)00100-0 · Cited by 962
Vision-based human motion analysis: An overview
Poppe, R. (2007) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2006.10.016 · Cited by 835
Objective assessment of technical skills in surgery
Moorthy, K., Munz, Y., Sarker, S. K., & Darzi, A. (2003) · BMJ · doi:10.1136/bmj.327.7422.1032 · Cited by 651
A contemporary approach to validity arguments: a practical guide to Kane's framework
Cook, D. A., Brydges, R., Ginsburg, S., & Hatala, R. (2015) · Medical Education · doi:10.1111/medu.12678 · Cited by 554 · cited 2×
“DISCUSSION This study demonstrates that computer vision capturing kinematic data from marker-less motion tracking of video records offers an objective and scalable approach for measuring surgical skill, and establishes evidence consistent with Kane’s validity framework.(13) We created subjective rating scales for flui…”
Sensitivity of Smoothness Measures to Movement Duration, Amplitude, and Arrests
Hogan, N., & Sternad, D. (2009) · Journal of Motor Behavior · doi:10.3200/35-09-004-rc · Cited by 440
View-Invariant Representation and Recognition of Actions
Rao, C., Yilmaz, A., & Shah, M. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020350100748 · Cited by 433 · cited 1×
“com Variable Selection The tracked record of the ROI location allowed quantification of instantaneous displacement, speed and acceleration of the surgeon’s hand, and several additional measures including jerk(41) and spatiotemporal curvature.(42) Jerk is the third derivative of position with respect to time and genera…”
Datta, V., Mackay, S., Mandalia, M., & Darzi, A. (2001) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(01)01041-9 · Cited by 415
Analysis of surgical errors in closed malpractice claims at 4 liability insurers
Rogers, S. O., Gawande, A. A., Kwaan, M., Puopolo, A. L., Yoon, C., Brennan, T. A., & Studdert, D. M. (2006) · Surgery · doi:10.1016/j.surg.2006.01.008 · Cited by 410
Darzi, A., Smith, S., & Taffinder, N. (1999) · BMJ · doi:10.1136/bmj.318.7188.887 · Cited by 347
Technical-Skills Training in the 21st Century
Aggarwal, R., & Darzi, A. (2006) · New England Journal of Medicine · doi:10.1056/nejme068179 · Cited by 277 · cited 1×
“Technical skill contributes to three-quarters of adverse events in the operating room,(7,8) but common methods of measuring performance (ie, in-training reports and mentor observations and evaluation) have been criticized for lacking reliability and being generally subjective(9) and are under increasing pressure to do…”
The relationship between motion analysis and surgical technical assessments
Datta, V., Chang, A., Mackay, S., & Darzi, A. (2002) · The American Journal of Surgery · doi:10.1016/s0002-9610(02)00891-7 · Cited by 274
Towards automatic skill evaluation: Detection and segmentation of robot-assisted surgical motions
Lin, H. C., Shafran, I., Yuh, D., & Hager, G. D. (2006) · Computer Aided Surgery · doi:10.3109/10929080600989189 · Cited by 254
Subjective rating scales: science or art?
Annett, J. (2002) · Ergonomics · doi:10.1080/00140130210166951 · Cited by 250
Review of methods for objective surgical skill evaluation
Reiley, C. E., Lin, H. C., Yuh, D. D., & Hager, G. D. (2011) · Surgical Endoscopy · doi:10.1007/s00464-010-1190-z · Cited by 249 · cited 1×
“Unfortunately, this self-contained system is limited to benchtop models and consequently not easily applied in the operating room.(26) Assessment in the operating room requires a noninvasive and scalable means of observing surgical motion without relying on embedded sensor technology.”
Postgame Analysis: Using Video-Based Coaching for Continuous Professional Development
Hu, Y.-Y., Peyre, S. E., Arriaga, A. F., Osteen, R. T., Corso, K. A., Weiser, T. G., Swanson, R. S., Ashley, S. W., Raut, C. P., Zinner, M. J., et al. (2012) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2011.10.009 · Cited by 221
Self-citationAggarwal, R., Grantcharov, T., Moorthy, K., Milland, T., & Darzi, A. (2008) · Annals of Surgery · doi:10.1097/sla.0b013e318160b371 · Cited by 180 · cited 1×
“Such measures are useful in providing objective and automatic feedback, and necessary in developing evidence of validity for future competency-based assessments.(48) There are several limitations to consider.”
Hatala, R., Cook, D. A., Brydges, R., & Hawkins, R. (2015) · Advances in Health Sciences Education · doi:10.1007/s10459-015-9593-1 · Cited by 176 · cited 1×
“Studies examining OSATS have demonstrated strong validity evidence in accordance with Kane’s framework,(12,13) especially in providing formative feedback during training.(14) Despite this proven track record, correctly implementing OSATS is resource-intensive and time-consuming,(15) prompting exploration of more effic…”
Zumel, N., & Mount, J. (2014) · Cited by 149
Slowing Down to Stay Out of Trouble in the Operating Room: Remaining Attentive in Automaticity
Moulton, C.-A., Regehr, G., Lingard, L., Merritt, C., & MacRae, H. (2010) · Academic Medicine · doi:10.1097/acm.0b013e3181f073dd · Cited by 140
The surgical efficiency score: a feasible, reliable, and valid method of skills assessment
Datta, V. K., Bann, S. D., Mandalia, M., & Darzi, A. W. (2006) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2006.06.001 · Cited by 95 · cited 1×
“Despite this proven track record, correctly implementing OSATS is resource-intensive and time-consuming,(15) prompting exploration of more efficient assessment techniques.(16,17) Motion capture and tracking of surgeon hand movements have the potential to fill these gaps.”
Idle time: an underdeveloped performance metric for assessing surgical skill
D’Angelo, A.-L. D., Rutherford, D. N., Ray, R. D., Laufer, S., Kwan, C., Cohen, E. R., Mason, A. H., & Pugh, C. M. (2015) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2014.12.013 · Cited by 83 · cited 1×
“Fluidity of motion is a measure of hesitancy, pauses, or changes in direction and ‘‘resets,’’ which may be a component of Moulton’s ‘‘slowing down,’’(35) or contribute to time spent idle.(36) Tissue handling quantifies the appropriateness of the surgeon’s force and tension when manipulating the tissue,(37,38) and vari…”
Self-citationYen, T. Y., & Radwin, R. G. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.412663 · Cited by 76 · cited 2×
“We reviewed the videos using Multimedia Video Task Analysis (MVTA) software (Wisconsin Alumni Research Foundation, Madison, WI) developed by Yen and Radwin.(33) MVTA allows real-time review, labeling, and exporting of video events.”
Self-citationValidation of the Imperial College Surgical Assessment Device (ICSAD) for labour epidural placement
Hayter, M. A., Friedman, Z., Bould, M. D., Hanlon, J. G., Katznelson, R., Borges, B. C. R., & Naik, V. N. (2009) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-009-9090-1 · Cited by 74
Grober, E. D., Roberts, M., Shin, E., Mahdi, M., & Bacal, V. (2009) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2009.07.033 · Cited by 70 · cited 1×
“Such behavior is consistently documented as a mark of expert psychomotor behavior, and increasingly studied as a measure of surgical skill.(25,39) A consensus panel of 3 expert surgeons (CCG, JAG, CMP) viewed each clip in random order and independently rated hand”
Quantifying technical skills during open operations using video-based motion analysis
Glarner, C. E., Hu, Y., Chen, C.-H., Radwin, R. G., Zhao, Q., Craven, M. W., Wiegmann, D. A., Pugh, C. M., Carty, M. J., & Greenberg, C. C. (2014) · Surgery · doi:10.1016/j.surg.2014.04.054 · Cited by 47
Self-citationAutomated Video Exposure Assessment of Repetitive Hand Activity Level for a Load Transfer Task
Chen, C.-H., Hu, Y. H., Yen, T. Y., & Radwin, R. G. (2012) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720812458121 · Cited by 38
Self-citationWatson, R. A. (2014) · Academic Medicine · doi:10.1097/acm.0000000000000316 · Cited by 37
A marker-less technique for measuring kinematics in the operating room
Frasier, L. L., Azari, D. P., Ma, Y., Quamme, S. R. P., Radwin, R. G., Pugh, C. M., Yen, T. Y., Chen, C.-H., & Greenberg, C. C. (2016) · Surgery · doi:10.1016/j.surg.2016.05.004 · Cited by 30 · cited 3×
“A full taxonomy and further information on the surgical procedures performed are described by Frasier et al.32”
InfluentialSelf-citationLaufer, S., D’Angelo, A.-L. D., Kwan, C., Ray, R. D., Yudkowsky, R., Boulet, J. R., McGaghie, W. C., & Pugh, C. M. (2016) · Annals of Surgery · doi:10.1097/sla.0000000000002024 · Cited by 28
Self-citationA frequency–duty cycle equation for the ACGIH hand activity level
Radwin, R. G., Azari, D. P., Lindstrom, M. J., Ulin, S. S., Armstrong, T. J., & Rempel, D. M. (2014) · Ergonomics · doi:10.1080/00140139.2014.966154 · Cited by 26
Self-citationThe Objective Assessment of Experts’ and Novices’ Suturing Skills Using An Image Analysis Program
Frischknecht, A. C., Kasten, S. J., Hamstra, S. J., Perkins, N. C., Gillespie, R. B., Armstrong, T. J., & Minter, R. M. (2012) · Academic Medicine · doi:10.1097/acm.0b013e31827c3411 · Cited by 24
A hand speed – duty cycle equation for estimating the ACGIH hand activity level rating
Akkas, O., Azari, D. P., Chen, C.-H. E., Hu, Y. H., Ulin, S. S., Armstrong, T. J., Rempel, D. M., & Radwin, R. G. (2014) · Ergonomics · doi:10.1080/00140139.2014.966155 · Cited by 20 · cited 2×
“We have also demonstrated how tracked hand motion can quantify kinematic properties of movements and exertions during specific tasks.(27,30,31) Previous studies by our group have used this technology to isolate kinematic differences in surgical hand motion,(20) and identify statistically significant differences betwee…”
Self-citationEvaluation of Simulated Clinical Breast Exam Motion Patterns Using Marker-Less Video Tracking
Azari, D. P., Pugh, C. M., Laufer, S., Kwan, C., Chen, C.-H., Yen, T. Y., Hu, Y. H., & Radwin, R. G. (2015) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720815613919 · Cited by 20 · cited 2×
“We have also demonstrated how tracked hand motion can quantify kinematic properties of movements and exertions during specific tasks.(27,30,31) Previous studies by our group have used this technology to isolate kinematic differences in surgical hand motion,(20) and identify statistically significant differences betwee…”
Self-citationLearning from Adverse Events and Near Misses
Greenberg, C. C. (2008) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-008-0693-6 · Cited by 18
Self-citationA motion tracking system for hand activity assessment
Chen, C.-H., Hu, Y. H., & Radwin, R. G. (2014) · doi:10.1109/chinasip.2014.6889256 · Cited by 14 · cited 1×
“We have also demonstrated how tracked hand motion can quantify kinematic properties of movements and exertions during specific tasks.(27,30,31) Previous studies by our group have used this technology to isolate kinematic differences in surgical hand motion,(20) and identify statistically significant differences betwee…”
Self-citationChen, C.-H., Azari, D. P., Hu, Y. H., Lindstrom, M. J., Thelen, D. G., Yen, T. Y., & Radwin, R. G. (2015) · Ergonomics · doi:10.1080/00140139.2015.1051594 · Cited by 11
Self-citationPugh, C. M. (2013) · Military Medicine · doi:10.7205/milmed-d-13-00215 · Cited by 11
Self-citationUsing crowd-assessment to support surgical training in the developing world
White, L. W., Lendvay, T. S., Holst, D. D., Borbély, Y., Bekele, A., & Wright, A. (2014) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2014.07.491 · Cited by 8 · cited 1×
“Despite this proven track record, correctly implementing OSATS is resource-intensive and time-consuming,(15) prompting exploration of more efficient assessment techniques.(16,17) Motion capture and tracking of surgeon hand movements have the potential to fill these gaps.”
Operative skill: quantifying surgeon's response to tissue properties
D’Angelo, A.-L. D., Rutherford, D. N., Ray, R. D., Mason, A. H., & Pugh, C. M. (2015) · Journal of Surgical Research · doi:10.1016/j.jss.2015.04.078 · Cited by 8 · cited 1×
“Tissue handling quantifies the appropriateness of the surgeon’s force and tension when manipulating the tissue,(37,38) and varies based on the tissue’s friability and fragility.(18) Motion economy is defined as efficiency of movement, or conservation of energy in any trajectory.”
Self-citationComputer-Aided Feedback of Surgical Knot Tying Using Optical Tracking
Watson, R. A. (2012) · Journal of surgical education · doi:10.1016/j.jsurg.2011.12.001 · Cited by 8 · cited 1×
“000 Hz) was applied to smooth the acceleration and curvature signals and a Fast Fourier Transform (FFT) function was applied to each signal set to isolate any consistently cyclic and repeated motion patterns, a growing avenue of research in surgical dexterity.(44) Moving averages were calculated for the original and s…”
Mackenzie, C. F., Watts, D., Patel, R. R., Yang, S., Garofalo, E. M., Puché, A. C., Pugh, K., Granite, G., Shalin, V. L., & Tisherman, S. A. (2016) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2016.08.166 · Cited by 3
Research works printed but not linked: 4
- Kane, 2006, Validation, Educational Measurement, 17
- Laufer, 2016, Rescuing the clinical breast examination, Ann Surg, XX, 1
- Greiner, 1991, Hand Anthropometry of U.S. Army Personell, Tech Rep Natick, 434
- Neter, 1990, Chapters 8–9: Building the Regression Model, Applied Linear Statistical Models
Cited by
Deep learning-enabled medical computer vision
Esteva, A., Chou, K., Yeung, S., Naik, N., Madani, A., Mottaghi, A., Liu, Y., Topol, E., Dean, J., & Socher, R. (2021) · npj Digital Medicine · doi:10.1038/s41746-020-00376-2 · Cited by 1,406
Machine learning for technical skill assessment in surgery: a systematic review
Lam, K., Chen, J., Wang, Z., Iqbal, F. M., Darzi, A., Lo, B., Purkayastha, S., & Kinross, J. M. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00566-0 · Cited by 174
Kitaguchi, D., Takeshita, N., Matsuzaki, H., Oda, T., Watanabe, M., Mori, K., Kobayashi, E., & Ito, M. (2020) · International Journal of Surgery · doi:10.1016/j.ijsu.2020.05.015 · Cited by 138
Wagner, M., Müller-Stich, B. P., Kisilenko, A., Tran, D., Heger, P., Mündermann, L., Lubotsky, D. M., Müller, B., Davitashvili, T., Capek, M., et al. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102770 · Cited by 173
Automated Methods of Technical Skill Assessment in Surgery: A Systematic Review
Levin, M., McKechnie, T., Khalid, S., Grantcharov, T., & Goldenberg, M. G. (2019) · Journal of surgical education · doi:10.1016/j.jsurg.2019.06.011 · Cited by 117
Metadata
- Authors
- Azari, D. P., Frasier, L. L., Quamme, S. R. P., Greenberg, C. C., Pugh, C. M., Greenberg, J. A., & Radwin, R. G.
- Affiliations
- University of Wisconsin–Madison (US)
- Corresponding author
- Azari, David P.
- Greenberg, Caprice C.
- Pugh, Carla M.
- Radwin, Robert G.
- ORCID
- Venue
- Annals of Surgery
- Published
- 2019-03
- Volume
- 269
- Issue
- 3
- Pages
- 574-581
- ISSN
- 0003-4932 (ISSN-L)
- 1528-1140
- PMC
- PMC7412996
- OpenAlex
- W2750898199
- Cited by
- 84
- References
- 47
- Citations by year
- 2026: 7 · 2025: 15 · 2024: 7 · 2023: 11 · 2022: 13 · 2021: 7 · 2020: 14 · 2019: 7
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Annals of Surgery (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (UL1TR000427)
- Agency for Healthcare Research and Quality (F32HS022403)
- National Cancer Institute (T32CA090217)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Social Sciences › Education › Innovations in Medical Education
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Keywords
- surgical skill assessment, computer vision, hand tracking, suturing, knot tying, OSATS, economy of motion, tissue handling, open surgery
- MeSH terms
- Algorithms, Artificial Intelligence, Biomechanical Phenomena, Clinical Competence, Female, Hand, Humans, Male, Models, Theoretical, Suture Techniques, Task Performance and Analysis, Video Recording, Reproducibility of Results, Observer Variation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.