Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 342

The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.

Physiological and Biochemical Basis of Clinical Liver Function Tests: A Review

Open access
Hoekstra, Lisette T., de Graaf, Wilmar, Nibourg, Geert A. A., Heger, Michal, Bennink, Roelof J., Stieger, Bruno, van Gulik, Thomas M.·2013·Annals of Surgery

Abstract

OBJECTIVE: To review the literature on the most clinically relevant and novel liver function tests used for the assessment of hepatic function before liver surgery. BACKGROUND: Postoperative liver failure is the major cause of mortality and morbidity after partial liver resection and develops as a result of insufficient remnant liver function. Therefore, accurate preoperative assessment of the future remnant liver function is mandatory in the selection of candidates for safe partial liver resection. METHODS: A MEDLINE search was performed using the key words "liver function tests," "functional studies in the liver," "compromised liver," "physiological basis," and "mechanistic background," with and without Boolean operators. RESULTS: Passive liver function tests, including biochemical parameters and clinical grading systems, are not accurate enough in predicting outcome after liver surgery. Dynamic quantitative liver function tests, such as the indocyanine green test and galactose elimination capacity, are more accurate as they measure the elimination process of a substance that is cleared and/or metabolized almost exclusively by the liver. However, these tests only measure global liver function. Nuclear imaging techniques ((99m)Tc-galactosyl serum albumin scintigraphy and (99m)Tc-mebrofenin hepatobiliary scintigraphy) can measure both total and future remnant liver function and potentially identify patients at risk for postresectional liver failure. CONCLUSIONS: Because of the complexity of liver function, one single test does not represent overall liver function. In addition to computed tomography volumetry, quantitative liver function tests should be used to determine whether a safe resection can be performed. Presently, (99m)Tc-mebrofenin hepatobiliary scintigraphy seems to be the most valuable quantitative liver function test, as it can measure multiple aspects of liver function in, specifically, the future remnant liver.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/sla.0b013e31825d5d47

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 61 references

Cited by

See all 342

Metadata

Authors
Hoekstra, L. T., de Graaf, W., Nibourg, G. A. A., Heger, M., Bennink, R. J., Stieger, B., & van Gulik, T. M.
Venue
Annals of Surgery
Published
2013-01
Volume
257
Issue
1
Pages
27-36
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2319478336
Cited by
342
References
61
FWCI
10.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physiological and Biochemical Basis of Clinical Liver Function Tests: A Review. https://app.cochat.ai/papers/10.1097/sla.0b013e31825d5d47
The paper
Hoekstra, L. T., de Graaf, W., Nibourg, G. A. A., Heger, M., Bennink, R. J., Stieger, B., & van Gulik, T. M. (2013). Physiological and Biochemical Basis of Clinical Liver Function Tests: A Review. Annals of Surgery. https://doi.org/10.1097/sla.0b013e31825d5d47

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.