Cited by 20Pelvic floor disorders treatmentsHernia repair and managementUterine Myomas and Treatments

Does Mesh Weight Affect Time to Failure After Robotic-Assisted Laparoscopic Sacrocolpopexy?

Askew, Amy L., Visco, Anthony G., Weidner, Alison C., Truong, Tracy, Siddiqui, Nazema Y., Bradley, Megan S.·2020·Female Pelvic Medicine & Reconstructive Surgery

Abstract

Objective: The objective of this study was to compare time to anatomic failure after robotic sacrocolpopexy with use of ultralightweight versus heavier weight mesh types. Methods: We performed a retrospective cohort study of women who underwent robotic sacrocolpopexy, from January 2012 to September 2016. We compared (1) sacrocolpopexy with ultralightweight mesh (≤20 g/m 2 ) versus (2) sacrocolpopexy with heavier weight mesh (≤35 g/m 2 ). Our primary outcome was time to anatomic failure, defined as recurrent prolapse beyond the hymen, or retreatment for prolapse with surgery or pessary. Secondary outcomes were compartment of failure and mesh exposure. Cox proportional hazards modeling was used to estimate the hazard of failure based on mesh type. Results: Of 461 patients, 248 (53.8%) underwent sacrocolpopexy with ultralightweight mesh and 213 (46.2%) with heavier weight mesh. Failures occurred in 37 women, with 21 in the ultralightweight mesh group and 16 in the heavier weight mesh group. Time to failure was statistically significant between groups ( P = 0.03). Ultralightweight mesh had twice the hazard of failure within 3 years compared with heavier weight mesh (hazard ratio, 2.15; 95% confidence interval, 1.10–4.21; P = 0.03). Among failures, use of ultralightweight mesh was associated with almost 5 times the hazard of anterior compartment failure (hazard ratio, 4.46; 95% confidence interval, 1.39–14.27; P = 0.01). There was no difference in time to posterior failure. Of 17 mesh exposures, there were fewer in the ultralightweight mesh group, although this group was followed for less time (1.6% ultralightweight vs 6.0% heavier weight, P = 0.01). Conclusions: Women receiving ultralightweight mesh are more likely to experience earlier anatomic failure in the anterior compartment.

Integrity signals

Registry

Crossref · 10.1097/spv.0000000000000632

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Askew, A. L., Visco, A. G., Weidner, A. C., Truong, T., Siddiqui, N. Y., & Bradley, M. S.
Affiliations
  • Duke Medical Center (US)
  • Division of Urogynecology and Reconstructive Pelvic Surgery, Department of Obstetrics and Gynecology
  • Duke University (US)
  • University of Pittsburgh (US)
Corresponding author
Askew, Amy L.
Venue
Female Pelvic Medicine & Reconstructive Surgery
Published
2018-10-15
Volume
26
Issue
9
Pages
536-540
ISSN
  • 2151-8378 (ISSN-L)
  • 2154-4212
OpenAlex
W2897286910
Cited by
20
References
23
Citations by year
2026: 2 · 2024: 3 · 2022: 6 · 2021: 4 · 2020: 3 · 2019: 2
FWCI
1.92
Type
journal article
Language
en
Open access
closed
Locations
  • Urogynecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Pelvic floor disorders treatments
  • Health Sciences › Medicine › Surgery › Hernia repair and management
  • Health Sciences › Medicine › Obstetrics and Gynecology › Uterine Myomas and Treatments
Keywords
mesh weight, pelvic organ prolapse, prolapse recurrence, mesh exposure
MeSH terms
Aged, Equipment Failure, Female, Humans, Middle Aged, Recurrence, Retrospective Studies, Surgical Mesh, Time Factors, Kaplan-Meier Estimate, Pelvic Organ Prolapse, Robotic Surgical Procedures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review