Clinical Utility of the Cobalt-Albumin Binding Assay in the Diagnosis of Intestinal Ischemia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Currently, the rapid diagnosis of mesenteric ischemia is problematic because of the nonspecificity of most laboratory assays and the unreliability of physical examinations. The evaluation of the cobalt-albumin binding assay (CABA) as a diagnostic marker for short-term risk stratification of emergency department patients presenting with symptoms of intestinal ischemia is reported. This preliminary study includes patients scheduled for exploratory laparotomy with symptoms of ischemic bowel and/or bowel obstruction. Approximately 10 mL of blood was drawn from each patient 1 hour preoperatively into a serum separator gel tube. After 30 minutes of clotting time, serum was collected and frozen at -80 degrees C. The CABA test was performed on the samples by an investigator blinded to the patient's condition, and values were compared with the clinical and pathologic diagnosis of ischemic bowel postoperatively. CABA test values are reported as absorbance units (ABSU) at 470 nm. Of the 26 patients enrolled in the study, 12 were clinically diagnosed with intestinal ischemia. These patients had significantly higher CABA test values (0.52 ABSU +/- 0.04 SEM) than patients without intestinal ischemia (0.31 ABSU +/- 0.02 SEM, p = 0.00023). Only two false-positives and no false-negatives were recorded. This resulted in a sensitivity of 100% and a specificity of 85.7% for the CABA test for these particular samples. The CABA test could be a useful tool for clinicians in the risk stratification of intestinal ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute Mesenteric Ischemia: A Clinical Review
Oldenburg, W. A., Lau, L. L., Rodenberg, T. J., Edmonds, H. J., & Burger, C. D. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.10.1054 · Cited by 714
Research works printed but not linked: 11
- McCaig, 2006, National hospital ambulatory medical care survey: 2004 emergency department summary., Adv Data, 372, 1
- Sreenarasimhaiah, 2003, Diagnosis and management of intestinal ischaemic disorders., BMJ, 326, 1372, 10.1136/bmj.326.7403.1372 · DOI · Paper page
- Bar-Or, 2001, Characterization of the Co(2+) and Ni(2+) binding amino-acid residues of the N-terminus of human albumin. An insight into the mechanism of a new assay for myocardial ischemia., Eur J Biochem, 268, 42, 10.1046/j.1432-1327.2001.01846.x · DOI · Paper page
- Sadler, 1994, Involvement of a lysine residue in the N-terminal Ni2+ and Cu2+ binding site of serum albumins. Comparison with Co2+, Cd2+ and Al3+., Eur J Biochem, 220, 193, 10.1111/j.1432-1033.1994.tb18614.x · DOI · Paper page
- Bar-Or, 2000, A novel assay for cobalt-albumin binding and its potential as a marker for myocardial ischemia-a preliminary report., J Emerg Med, 19, 311, 10.1016/S0736-4679(00)00255-9 · DOI · Paper page
- Bar-Or, 2001, Reduced albumin-cobalt binding with transient myocardial ischemia after elective percutaneous transluminal coronary angioplasty: a preliminary comparison to creatine kinase-MB, myoglobin, and troponin I., Am Heart J, 141, 985, 10.1067/mhj.2001.114800 · DOI · Paper page
- Bhagavan, 2003, Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction., Clin Chem, 49, 581, 10.1373/49.4.581 · DOI · Paper page
- Sinha, 2003, Ischemia modified albumin is a sensitive marker of myocardial ischemia after percutaneous coronary intervention., Circulation, 107, 2403, 10.1161/01.CIR.0000072764.18315.6B · DOI · Paper page
- Christenson, 2001, Characteristics of an albumin cobalt binding test for assessment of acute coronary syndrome patients: a multicenter study., Clin Chem, 47, 464, 10.1093/clinchem/47.3.464 · DOI · Paper page
- Can, 2006, Evaluation of effects of ischaemia on the albumin cobalt binding (ACB) assay in patients exposed to trauma., Emerg Med J, 23, 537, 10.1136/emj.2005.030486 · DOI
- Mallick, 2004, Ischemia-reperfusion injury of the intestine and protective strategies against injury., Dig Dis Sci, 49, 1359, 10.1023/B:DDAS.0000042232.98927.91 · DOI · Paper page
Cited by
The Diagnosis of Acute Mesenteric Ischemia: A Systematic Review and Meta-analysis
Cudnik, M. T., Darbha, S., Jones, J., Macedo, J., Stockton, S. W., & Hiestand, B. C. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12254 · Cited by 275
Evennett, N. J., Petrov, M. S., Mittal, A., & Windsor, J. A. (2009) · World Journal of Surgery · doi:10.1007/s00268-009-0074-7 · Cited by 270
Current status on plasma biomarkers for acute mesenteric ischemia
Acosta, S., & Nilsson, T. (2012) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-011-0660-z · Cited by 157
“Polk [60] 2008 Cobalt-albumin 26 Need of explorative laparotomy Prospective 100 86”
BackgroundTreskes, N., Persoon, A. M., & van Zanten, A. R. H. (2017) · Internal and Emergency Medicine · doi:10.1007/s11739-017-1668-y · Cited by 135
Diagnostic performance of plasma biomarkers in patients with acute intestinal ischaemia
Matsumoto, S., Sekine, K., Funaoka, H., Yamazaki, M., Shimizu, M., Hayashida, K., & Kitano, M. (2014) · British Journal of Surgery · doi:10.1002/bjs.9331 · Cited by 135
Metadata
- Authors
- Polk, J. D., Rael, L. T., Craun, M. L., Mains, C. W., Davis-Merritt, D., & Bar-Or, D.
- Venue
- Journal of Trauma: Injury, Infection & Critical Care
- Published
- 2008-01
- Volume
- 64
- Issue
- 1
- Pages
- 42-45
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2074851095
- Cited by
- 47
- References
- 1
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Utility of the Cobalt-Albumin Binding Assay in the Diagnosis of Intestinal Ischemia. https://app.cochat.ai/papers/10.1097/ta.0b013e31815b846a
- The paper
- Polk, J. D., Rael, L. T., Craun, M. L., Mains, C. W., Davis-Merritt, D., & Bar-Or, D. (2008). Clinical Utility of the Cobalt-Albumin Binding Assay in the Diagnosis of Intestinal Ischemia. Journal of Trauma: Injury, Infection & Critical Care. https://doi.org/10.1097/ta.0b013e31815b846a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.