Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 258

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Clinical Relevance of Pretransplant Donor-Specific HLA Antibodies Detected by Single-Antigen Flow-Beads

Amico, Patrizia, Hönger, Gideon, Mayr, Michael, Steiger, Jürg, Hopfer, Helmut, Schaub, Stefan · 2009 · Transplantation

Abstract

BACKGROUND: Defining the clinical relevance of donor-specific HLA-antibodies detected by single-antigen flow-beads (SAFB) is important because these assays are increasingly used for pretransplant risk assessment and organ allocation. The aims of this study were to investigate to which extent HLA-DSA detected by SAFB represent a risk for antibody-mediated rejection (AMR) and diminished allograft survival, and to define HLA-DSA characteristics predictive for AMR. METHODS: In this retrospective study of 334 patients with negative complement-dependent cytotoxicity crossmatches, day-of-transplant sera were analyzed by SAFB, HLA-DSA determined by virtual crossmatching, and the results correlated with the occurrence of AMR and allograft survival. RESULTS: Sixty-seven of 334 patients (20%) had HLA-DSA. The incidence of clinical/subclinical AMR at day 200 posttransplant was significantly higher in patients with HLA-DSA than in patients without HLA-DSA (55% vs. 6%; P<0.0001). Notably, 30/67 patients with HLA-DSA (45%) did not experience clinical/subclinical AMR. Death-censored 5-year allograft survival was equal in patient without HLA-DSA and patients with HLA-DSA but no AMR (89% vs. 87%; P=0.95), whereas it was 20% lower in patients with HLA-DSA and AMR (68%; P=0.002). The number, class, and cumulative strength of HLA-DSA determined by SAFB, and prior sensitizing events were not predictive for the occurrence of AMR. CONCLUSIONS: These results support the utility of SAFB for pretransplant risk assessment and organ allocation, and suggest that improvement of the positive predictive value of HLA-DSA defined by SAFB will require an enhanced definition of pathogenic factors of HLA-DSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/tp.0b013e3181a5e034

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 258

Metadata

Authors
Amico, P., Hönger, G., Mayr, M., Steiger, J., Hopfer, H., & Schaub, S.
Venue
Transplantation
Published
2009-06-15
Volume
87
Issue
11
Pages
1681-1688
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2022076910
Cited by
258
References
19
FWCI
14.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Relevance of Pretransplant Donor-Specific HLA Antibodies Detected by Single-Antigen Flow-Beads. https://app.cochat.ai/papers/10.1097/tp.0b013e3181a5e034
The paper
Amico, P., Hönger, G., Mayr, M., Steiger, J., Hopfer, H., & Schaub, S. (2009). Clinical Relevance of Pretransplant Donor-Specific HLA Antibodies Detected by Single-Antigen Flow-Beads. Transplantation. https://doi.org/10.1097/tp.0b013e3181a5e034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.