Temporal Stability of Auditory Event-Related Potentials in Healthy Individuals and Patients With Traumatic Brain Injury
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Historically, cognitive event-related potentials (ERPs) have received limited acceptance for clinical use due to lack of evidence for their reliability. However, recent advances in computer technology and artifact rejection methods have greatly enhanced the fidelity of ERP measurements. The present study examined the test-retest reliability of ERP measurement by using current data processing methods. We assessed the temporal stability of the most commonly used ERP paradigm, auditory pure-tone "odd ball" detection, and compared it with other commonly used clinical measures reported in the literature. Auditory ERPs were collected in 19 healthy subjects and 7 patients with traumatic brain injury at two time points, 2 days to 2 months apart. Test-retest reliability was calculated for four ERP components: N1, MMN (mismatch negativity), P3, and N4. In healthy subjects, temporal stabilities of these four commonly studied ERP components' amplitude measurements were moderate to high, with intraclass correlations ranging from 0.6 to 0.8. In contrast, in patients with traumatic brain injury, ERPs were stable only for the N1 component (intraclass correlation = 0.7).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Näätänen, R., & Picton, T. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00311.x · Cited by 3,321
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157 · cited 1×
“Additionally, the substantial heterogeneity associated with our control group attests to the robustness of the reliability of these ERP measures when using a standardized ERP paradigm and current signal processing methods (Picton et al., 2000).”
MethodWILLIAMS, L. M., SIMMS, E., CLARK, C. R., PAUL, R. H., ROWE, D., & GORDON, E. (2005) · International Journal of Neuroscience · doi:10.1080/00207450590958475 · Cited by 293
Reduced P300 responses in criminal psychopaths during a visual oddball task
Kiehl, K. A., Hare, R. D., Liddle, P. F., & McDonald, J. J. (1999) · Biological Psychiatry · doi:10.1016/s0006-3223(98)00193-0 · Cited by 165 · cited 2×
“…the past several decades, researchers have system-atically studied electrophysiologic responses of the brain to various stimuli, leading to important discoveries about information processing (Duzel et al., 2001; Fallgatter, 2001; Ford et al., 2004; Kiehl et al., 1999; Knight et al., 1989).”
Background
Cited by
Mismatch negativity (MMN), the deviance-elicited auditory deflection, explained
May, P. J. C., & Tiitinen, H. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2009.00856.x · Cited by 549
McCleery, A., Mathalon, D. H., Wynn, J. K., Roach, B. J., Hellemann, G. S., Marder, S. R., & Green, M. F. (2019) · Psychological Medicine · doi:10.1017/s0033291718004087 · Cited by 35
“non-roving) paradigms have previously been shown to have moderate-to-good test-retest reliability in SZ (Light and Braff, 2005; Hall et al., 2006; Lew et al., 2007; Light et al., 2012; Biagianti et al., 2017).”
BackgroundWynn, J. K., & Green, M. F. (2024) · Clinical EEG and Neuroscience · doi:10.1177/15500594241252897 · Cited by 3
Metadata
- Authors
- Lew, H. L., Gray, M., & Poole, J. H.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 2007-10
- Volume
- 24
- Issue
- 5
- Pages
- 392-397
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2047462232
- Cited by
- 58
- References
- 4
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.