Tremor varies as a function of the temporal regularity of deep brain stimulation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The frequency of stimulation is one of the primary factors determining the effectiveness of deep brain stimulation (DBS) in relieving tremor. DBS efficacy, however, may depend not only on the average frequency of stimulation, but also on the temporal pattern of stimulation. We conducted intraoperative measurements of the effect of temporally irregular DBS (nonconstant interpulse intervals) on tremor. As the coefficient of variation of irregular high frequency DBS trains increased, they became less effective at reducing tremor (mixed effects regression model, P<0.04). These data provide evidence that the effects of DBS are dependent not only on the average frequency of DBS, but also on the regularity of the temporal spacing of DBS pulses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus
Benabid, A. L., Pollak, P., Hoffmann, D., Gervason, C., Hommel, M., Perret, J. E., de Rougemont, J., & Gao, D. M. (1991) · The Lancet · doi:10.1016/0140-6736(91)91175-t · Cited by 1,787 · cited 2×
“The stimulation frequency has a strong impact on outcomes, and maximal reductions in tremor are typically observed only when the frequency is ≥90Hz [1-5].”
BackgroundLenz, F. A., Kwan, H. C., Martin, R. L., Tasker, R. R., Dostrovsky, J. O., & Lenz, Y. E. (1994) · Brain · doi:10.1093/brain/117.3.531 · Cited by 374
Hua, S. E., & Lenz, F. A. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00527.2004 · Cited by 134 · cited 2×
“Under this hypothesis, even if irregular DBS is able to override pathological bursting [14,15], it may be unable to drive regular firing patterns, and thus is clinically ineffective.”
Background
Cited by
Network perspectives on the mechanisms of deep brain stimulation
McIntyre, C. C., & Hahn, P. J. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.09.022 · Cited by 439
“Birdno et al. (2007, 2008) introduced randomness into the interpulse timing of high frequency DBS and evaluated its effects on controlling tremor.”
BackgroundClosed-Loop Control of Deep Brain Stimulation: A Simulation Study
Santaniello, S., Fiengo, G., Glielmo, L., & Grill, W. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2081377 · Cited by 202
Self-citationPrinciples of electrical stimulation of neural tissue
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00001-2 · Cited by 151
Self-citationShah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21
“These descriptions were mostly for research purposes, for example the one-time use of inertial sensors during a thalamotomy [21], the evaluation of the effect of non-constant inter-pulse intervals of DBS stimulation on tremor [4], or the identification of a target structure by spectral correlation of a tremor signal f…”
Background
Metadata
- Authors
- Birdno, M. J., Kuncel, A. M., Dorval, A. D., Turner, D. A., & Grill, W. M.
- Venue
- NeuroReport
- Published
- 2008-03-26
- Volume
- 19
- Issue
- 5
- Pages
- 599-602
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2077745752
- Cited by
- 68
- References
- 3
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.