The DOI matches its Crossref record; 209 of the 209 references it cites were found in a registry or an index.
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Open accessAbstract
Cancer remains one of the leading causes of death, albeit enormous efforts to cure the disease. To overcome the major challenges in cancer therapy, we need to have a better understanding of the tumour microenvironment (TME), as well as a more effective means to screen anti-cancer drug leads; both can be achieved using advanced technologies, including the emerging tumour-on-a-chip technology. Here, we review the recent development of the tumour-on-a-chip technology, which integrates microfluidics, microfabrication, tissue engineering and biomaterials research, and offers new opportunities for building and applying functional three-dimensional in vitro human tumour models for oncology research, immunotherapy studies and drug screening. In particular, tumour-on-a-chip microdevices allow well-controlled microscopic studies of the interaction among tumour cells, immune cells and cells in the TME, of which simple tissue cultures and animal models are not amenable to do. The challenges in developing the next-generation tumour-on-a-chip technology are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These tumor-on-chip systems are expected to increase the effective identification of new and better cancer therapies while minimizing non-specific toxicity [13,14,15,16,17].”
From The Tumor-on-Chip: Recent Advances in the Development of Microfluidic Systems to Recapitulate the Physiology of Solid Tumors (2019) · cites this paper as [14]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Tumor-on-chip models based on these organ-on-chip systems can recreate human tumor microenvironments and now hold great promise as a new resource for cost-effective and higher-throughput screening of anticancer drugs [13,14,15,16,17] and powerful enablers of precision medicine [18].”
From The Tumor-on-Chip: Recent Advances in the Development of Microfluidic Systems to Recapitulate the Physiology of Solid Tumors (2019) · cites this paper as [14]
The cited source says what the claim attributes to it.
In the citing paper
“Tumor-on-chip models based on these organ-on-chip systems can recreate human tumor microenvironments and now hold great promise as a new resource for cost-effective and higher-throughput screening of anticancer drugs [13,14,15,16,17] and powerful enablers of precision medicine [18].”
From The Tumor-on-Chip: Recent Advances in the Development of Microfluidic Systems to Recapitulate the Physiology of Solid Tumors (2019) · cites this paper as [14]
In the citing paper
“Ideally, tumor-on-a-chip platforms have the ability to recreate many cardinal TME features and show great promise as a novel technology for studying the mechanisms of tumor evolution, screening anticancer drugs and cancer therapies, and enabling precision medicine14,112,117–122.”
From Tumor-on-a-chip: from bioinspired design to biomedical application (2021) · cites this paper as [14]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the Warburg Effect: The Metabolic Requirements of Cell Proliferation
Vander Heiden, M. G., Cantley, L. C., & Thompson, C. B. (2009) · Science · doi:10.1126/science.1160809 · Cited by 16,197
Microenvironmental regulation of tumor progression and metastasis
Quail, D. F., & Joyce, J. A. (2013) · Nature Medicine · doi:10.1038/nm.3394 · Cited by 7,994
3D bioprinting of tissues and organs
Murphy, S. V., & Atala, A. (2014) · Nature Biotechnology · doi:10.1038/nbt.2958 · Cited by 7,034
Hydrogels for tissue engineering: scaffold design variables and applications
Drury, J. L., & Mooney, D. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00340-5 · Cited by 5,136
A Perspective on Cancer Cell Metastasis
Chaffer, C. L., & Weinberg, R. A. (2011) · Science · doi:10.1126/science.1203543 · Cited by 4,905
Tumor Metastasis: Molecular Insights and Evolving Paradigms
Valastyan, S., & Weinberg, R. A. (2011) · Cell · doi:10.1016/j.cell.2011.09.024 · Cited by 4,011
Porous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,979
Tumour-cell invasion and migration: diversity and escape mechanisms
Friedl, P., & Wolf, K. (2003) · Nature reviews. Cancer · doi:10.1038/nrc1075 · Cited by 3,350
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Raise standards for preclinical cancer research
Begley, C. G., & Ellis, L. M. (2012) · Nature · doi:10.1038/483531a · Cited by 2,979
Flagged first, then by citations
Cited by
Sorted by citations
Targeting Tumor Microenvironment for Cancer Therapy
Roma-Rodrigues, C., Mendes, R., Baptista, P. V., & Fernandes, A. R. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20040840 · Cited by 1,187
Hydrogel microenvironments for cancer spheroid growth and drug screening
Li, Y., & Kumacheva, E. (2018) · Science Advances · doi:10.1126/sciadv.aas8998 · Cited by 356
Tumor-on-a-chip: from bioinspired design to biomedical application
Liu, X., Fang, J., Huang, S., Wu, X., Xie, X., Wang, J., Liu, F., Zhang, M., Peng, Z., & Hu, N. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00277-8 · Cited by 246
Saxena, K., & Jolly, M. K. (2019) · Biomolecules · doi:10.3390/biom9080339 · Cited by 223
Organ-on-a-Chip for Cancer and Immune Organs Modeling
Sun, W., Luo, Z., Lee, J., Kim, H., Lee, K., Tebon, P., Feng, Y., Dokmeci, M. R., Sengupta, S., & Khademhosseini, A. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801363 · Cited by 221
Metadata
- Authors
- Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G.
- Affiliations
- Okinawa Institute of Science and Technology Graduate University (JP)
- Rice University (US)
- Corresponding author
- Shen, Amy Q.
- Bao, Gang
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2017-06
- Volume
- 14
- Issue
- 131
- Pages
- 20170137
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- PMC
- PMC5493797
- OpenAlex
- W2695955856
- Cited by
- 214
- References
- 209
- Citations by year
- 2026: 13 · 2025: 13 · 2024: 26 · 2023: 26 · 2022: 25 · 2021: 18 · 2020: 28 · 2019: 44 · 2018: 20 · 2017: 1
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of The Royal Society Interface (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion, cc-by-nc-nd)
- Okinawa Institute of Science and Technology Graduate University (Okinawa Institute of Science and Technology Graduate University) (submittedVersion, cc-by-nc-nd)
- Funders
- Cancer Prevention and Research Institute of Texas (RR140081)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- tumor microenvironment, anticancer drug screening, tumor growth, tumor morphology, immunotherapy, tissue engineering, biomaterials, microfabrication
- MeSH terms
- Humans, Models, Biological, Neoplasms, Tissue Engineering, Microfluidics, Microfluidic Analytical Techniques, Microtechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review