Robust parameter extraction for decision support using multimodal intensive care data
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Digital information flow within the intensive care unit (ICU) continues to grow, with advances in technology and computational biology. Recent developments in the integration and archiving of these data have resulted in new opportunities for data analysis and clinical feedback. New problems associated with ICU databases have also arisen. ICU data are high-dimensional, often sparse, asynchronous and irregularly sampled, as well as being non-stationary, noisy and subject to frequent exogenous perturbations by clinical staff. Relationships between different physiological parameters are usually nonlinear (except within restricted ranges), and the equipment used to measure the observables is often inherently error-prone and biased. The prior probabilities associated with an individual's genetics, pre-existing conditions, lifestyle and ongoing medical treatment all affect prediction and classification accuracy. In this paper, we describe some of the key problems and associated methods that hold promise for robust parameter extraction and data fusion for use in clinical decision support in the ICU.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Self-citationWavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908 · cited 1×
“2006) and wavelets (Addison 2005).”
Automated de-identification of free-text medical records
Neamatullah, I., Douglass, M. M., Lehman, L.-W. H., Reisner, A., Villarroel, M., Long, W. J., Szolovits, P., Moody, G. B., Mark, R. G., & Clifford, G. D. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-32 · Cited by 413 · cited 1×
“2004; Neamatullah et al .”
Self-citationThe hostile environment of the intensive care unit
Donchin, Y., & Seagull, F. J. (2002) · Current Opinion in Critical Care · doi:10.1097/00075198-200208000-00008 · Cited by 297 · cited 1×
“The resultant excessive noise pollution, desensitization to warnings and slowing of response times (Chambrin 2001) can lead to missed alarms, decreased quality of care (Donchin & Jacob 2002; Imhoff & Kuhls 2006), sleep problems (Meyer et al .”
BackgroundAssessing Data Quality in Manual Entry of Ventilator Settings
Vawdrey, D. K., Gardner, R. M., Evans, R. S., Orme, J. F., Clemmer, T. P., Greenway, L., & Drews, F. A. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2219 · Cited by 48 · cited 2×
“At an even more basic level, it is necessary to match each recorded data stream with the correct patient among all those currently in the hospital, a problem that should be trivially easy to solve but is often complicated by instruments with poorly designed set-up procedures that are not always completed in the contex…”
Background
Cited by
Machine Learning and Decision Support in Critical Care
Johnson, A. E. W., Ghassemi, M. M., Nemati, S., Niehaus, K. E., Clifton, D., & Clifford, G. D. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2501978 · Cited by 432
Self-citationChallenges and Research Directions in Medical Cyber–Physical Systems
Lee, I., Sokolsky, O., Chen, S., Hatcliff, J., Jee, E., Kim, B., King, A., Mullen-Fortino, M., Park, S., Roederer, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165270 · Cited by 373
–Omic and Electronic Health Record Big Data Analytics for Precision Medicine
Wu, P.-Y., Cheng, C.-W., Kaddi, C. D., Venugopalan, J., Hoffman, R., & Wang, M. D. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2573285 · Cited by 303
Review of Cyber-Physical System in Healthcare
Haque, S. A., Aziz, S. M., & Rahman, M. (2014) · International Journal of Distributed Sensor Networks · doi:10.1155/2014/217415 · Cited by 262
Gaussian processes for personalized e-health monitoring with wearable sensors
Clifton, L., Clifton, D. A., Pimentel, M. A. F., Watkinson, P. J., & Tarassenko, L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208459 · Cited by 117
“The limiting factor of existing techniques is typically deemed to be how they handle those commonly encountered periods of signal artifact, which arise due to patient movement, wearable sensor failure, and communication failures; currently, such periods are identified, and the incomplete or noisy vital-sign data repla…”
Background
Metadata
- Authors
- Clifford, G. D., Long, W. J., Moody, G. B., & Szolovits, P.
- Venue
- Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2008-10-20
- Volume
- 367
- Issue
- 1887
- Pages
- 411-429
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W2113090945
- Cited by
- 86
- References
- 5
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust parameter extraction for decision support using multimodal intensive care data. https://app.cochat.ai/papers/10.1098/rsta.2008.0157
- The paper
- Clifford, G. D., Long, W. J., Moody, G. B., & Szolovits, P. (2009). Robust parameter extraction for decision support using multimodal intensive care data. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences. https://doi.org/10.1098/rsta.2008.0157
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.